User Manual for ABB models including: NS53E-20 Contactor Relay, NS53E-20, Contactor Relay, Relay
ABB NS53E-20 | 24V50/60HZ Contactor Relay-NS53E-20
PRODUCT-DETAILS NS53E-20 NS53E-20 24V50/60HZ Contactor Relay General Information Extended Product Type Product ID EAN Catalog Description Long Description Ordering Minimum Order Quantity Customs Tariff Number Popular Downloads Instructions and Manuals CAD Dimensional Drawing NS53E-20 1SBH101001R2053 3471523006201 NS53E-20 24V50/60HZ Contactor Relay NS... contactor relays are used for switching auxiliary circuits and control circuits. - Poles: 8pole contactor relays (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor relay side) - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available. 1 piece 85364900 1SBC101020M9701 2CDC001079B0201 © 2023 ABB. All rights reserved. 2023/08/10 Subject to change without notice NS53E-20 Dimensions Product Net Width Product Net Depth / Length Product Net Height Product Net Weight Technical Number of Auxiliary Contacts NO Number of Auxiliary Contacts NC Standards Rated Operational Voltage Rated Frequency (f) Conventional Free-air Thermal Current (Ith) Rated Operational Current AC-15 (Ie) Rated Short-time Withstand Current Low Voltage (Icw) Maximum Electrical Switching Frequency Rated Operational Current DC-13 (Ie) Rated Insulation Voltage (Ui) Rated Impulse Withstand Voltage (Uimp) Maximum Mechanical Switching Frequency Rated Control Circuit Voltage (Uc) Operate Time Connecting Capacity Auxiliary Circuit Connecting Capacity Control Circuit Wire Stripping Length Degree of Protection Terminal Type © 2023 ABB. All rights reserved. 2 45 mm 100.2 mm 68 mm 0.26 kg 5 3 IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14 Auxiliary Circuit 690 V Main Circuit 690 V Auxiliary Circuit 50 / 60 Hz acc. to IEC 60947-5-1, = 40 °C 10 A (500 V) NC 2 (500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A for 0.1 s 140 A for 1 s 100 A (AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour (24 V) 6 A / 144 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (250 V) 0.27 A / 68 W acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V Auxiliary Circuit 6 kV 3600 cycles per hour 50 Hz 24 V 60 Hz 24 V Between Coil De-energization and NC Contact Closing 7 ... 22 ms Between Coil De-energization and NO Contact Opening 5 ... 19 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms Between Coil Energization and NO Contact Closing 9 ... 24 ms Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm² Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm² Auxiliary Circuit 9 mm Control Circuit 9 mm acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 Screw Terminals 2023/08/10 Subject to change without notice NS53E-20 Technical UL/CSA Tightening Torque UL/CSA Environmental Ambient Air Temperature Climatic Withstand Maximum Operating Altitude Permissible Resistance to Vibrations acc. to IEC 60068-2-6 Resistance to Shock acc. to IEC 60068-2-27 RoHS Status Certificates and Declarations CB Certificate CCC Certificate CQC Certificate Declaration of Conformity - CCC Declaration of Conformity - CE Declaration of Conformity - UKCA GOST Certificate UL Certificate UL Listing Card Container Information Package Level 1 Units Package Level 1 Width Package Level 1 Depth / Length Package Level 1 Height Package Level 1 Gross Weight Package Level 1 EAN Package Level 2 Units Package Level 2 Width Package Level 2 Depth / Length Package Level 2 Height Package Level 2 Gross Weight Package Level 3 Units © 2023 ABB. All rights reserved. 3 Auxiliary Circuit 9 in·lb Control Circuit 9 in·lb Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C Category B according to IEC 60947-1 Annex Q Without Derating 3000 m 5 ... 300 Hz 3 g Closed position / 2 g Open position Closed, Shock Direction: C1 19 g Closed, Shock Direction: C2 16 g Open, Shock Direction: C1 8 g Open, Shock Direction: C2 13 g Shock Direction: A 20 g Shock Direction: B1 5 g Shock Direction: B2 15 g Following EU Directive 2002/95/EC August 18, 2005 and amendment CB_CN_32453 CCC_2007010305248106 CQC2007010305248106 2020980304001219 1SBD250016U1000 1SBD250051U1000 GOST_POCCCNME77B07821.pdf UL_220108-E312527A NOA_E312527.pdf 2023/08/10 1 piece 72 mm 115 mm 48 mm 0.26 kg 3471523006201 32 piece 250 mm 315 mm 195 mm 8.32 kg 768 piece Subject to change without notice NS53E-20 Classifications Object Classification Code ETIM 4 ETIM 5 ETIM 6 ETIM 7 ETIM 8 eClass UNSPSC IDEA Granular Category Code (IGCC) 4 K EC000196 - Contactor relay EC000196 - Contactor relay EC000196 - Contactor relay EC000196 - Contactor relay EC000196 - Contactor relay V11.0 : 27371001 39121529 4761 >> Magnet contactor, AC-switching Categories Low Voltage Products and Systems Control Products Contactors Block Contactors © 2023 ABB. All rights reserved. 2023/08/10 Subject to change without noticeTelerik Reporting 17.0.23.315 (https://www.telerik.com/products/reporting.aspx) Telerik Reporting 17.0.23.315 (https://www.telerik.com/products/reporting.aspx)