5 - - 6 - - 7 - - 8 - E. GeneralMaintenance Beyond replacing batteriesand fuses, do not attemptto repair or service the product unless you are qualifiedto do so and ...

مولتی متر کلمپی زویی ZOYI مدل ZT-QB1 | فروشگاه تکترونیکس

PowerPoint 演示文稿

PDF preview unavailable. Download the PDF instead.

1966 orig
User Manual
-1-

A. Introduction
This product is a battery-powered, true-rms, auto ranging digital clamp multimeter with a 4000 counts LCD display and a backlight.
B. Safety Information
To avoid possible electrical shock, fire, or personal injury, please read all safety information before you use the product.
(1) Do NOT exceed the "maximum value" indicated in the Specification. (2) Examine the connection of the test leads and the insulation of the product
before measuring voltage higher than 36V DC or 25V AC. (3) Disconnect the test leads from the circuit before changing the mode (4) Misuse of mode or range can lead to hazards, be cautious. "OL" will be shown
on the display when the input is out of range. (5) Safety symbols:

Hazardous Voltage

Earth

Double Insulated

Low Battery

Risk of Danger. Check the User Manual.

N/ L Wire Judgement

C. Specifications

Function

Electrical Specifications

Range

Resolution

Accuracy

MAX.Val ue

Frequency Response

4.000V 0.001V

DC Voltage 40.00V (V) 400.0V

0.01V 0.1V

±(0.5%+3) 600V

600V

1V

4.000V 0.001V

AC Voltage 40.00V (V) 400.0V

0.01V 0.1V

±(1.0%+3) 600V

40Hz-1kHz

600V

1V

4.000A 0.004A

±(5%+5)

40.00A AC Current
(A) 400.0A

0.01A 0.01A

600A ±(2.5%+8)

40Hz-1kHz

600A

1A

-2-

Function
Resistance
Frequency
Continuity Inrush Current
Peak Hold Flashlight

Range 4.000k 40.00k 400.0k 4.000M
40.00M 4.000Hz 40.00Hz 400.0Hz 4.000kHz 40.00kHz
100.0kHz

Resolution 0.001k 0.01k 0.1k 0.001M
0.01M 0.001Hz 0.01Hz
0.1Hz 0.001kHz 0.01kHz
0.1kHz

Accuracy ±(1.5%+3)
±(0.5%+3) ±(1.5%+3)
±(0.1%+2)    

MAX.Value Frequency Response 40M
100kHz

General Specifications

DisplayLCD

4000 counts

Ranging

Auto

Material

ABS

Update Rate Ture RMS Data Hold Low Battery Alert Auto Power Off

3 times/second
   

Mechanical Specifications

Dimension

172*64*32mm

Weight

172g

Battery Type

1.5V AA Battery * 2

Warranty

One year

Environmental Specifications

Operating

Temperature Humidity

0~40 75%

Storage

Temperature Humidity

-20~60 80%

D. Instruction

1

(1) Front Panelsee the picture on the right

1. Jaw

2. Flashlight

11

3. Jaw release

4. Hold / Inrush Current / Peak Hold

HOLD: To press this button once and you will see

"HOLD" on the display;

Inrush Current: To press this button twice

3

and you will see "INRUSH" on the display;

Peak Hold: To press this button twice after

connecting test leads to the Terminals and you

will see "Peak HOLD" on the display;

5

5. Power / Select

Power: Press this button for more than 2 seconds

to turn it on / off.

Select: Press this button for switching functions

after connecting test leads to the Terminals.

6. Frequency / NCV: Press this button over 2 seconds

into NCV mode and exit from release.

7. LCD display

8. COM: Common terminal for all measurements.

8

10
2 4 6 7
9

9.

: Input terminal for voltage, resistance, frequency, and continuity

measurements and judging N/L wires.

10. Wire to be measured

11. Marked position

(2) Measure AC/DC Voltage

1. The minimum voltage of this product is 0.8V. When the measured voltage is higher

than 0.8V, the product will display the reading;

2. Connect the black test lead to the COM Terminal and connect the red test lead to

the

Terminal;

3. The DC or AC voltage will be matched automatically;

4. Touch the probes to the correct test points of the circuit to measure the voltage;

5. Read the measured voltage on the display. *Caution:

a. Do not measure voltage that exceeds the MAX Value as indicated in the

Specifications; b. Do not touch high voltage circuit during measurements.

-3-

-4-

(3) Measure AC Current Only
1. Keep the probes not in the jacks, turn power switch on; 2. Push the jaw release and center the wire within the clamp jaws (as in the picture).
The wire should be in the marked position to keep measurement accuracy. 3. Read the measured current on the display. *Caution: a. Do not measure current that exceeds the MAX Value as indicated in the
Specifications; b. Measure one wire at a time because current moving in different directions
will cancel each other out.

(4) Measure Resistance

1. Connect the black test lead to the COM Terminal and connect the red test lead to

the

Terminal;

2. The resistance will be matched automatically;

3. Touch the probes to the desired test points of the circuit to measure the resistance;

4. Read the measured resistance on the display.

*Caution:

a. Disconnect circuit power and discharge all capacitors before you test resistance.

b. Do not input voltage at the Resistance Mode.

(5) Measure Continuity

1. Connect the black test lead to the COM Terminal and connect the red test lead to

the

Terminal;

2. Press SEL / Power once to toggle to the Continuity/Diode Mode;

3. Touch the probes to the desired test points of the circuit; 4. The built-in beeper will beep when the resistance is lower than 50, and the

indicator light will be on.

*Caution:

Do not input voltage at the Continuity / Diode Mode.

(6) Measure Frequency

1. Connect the black test lead to the COM Terminal and connect the red test lead to

the

Terminal;

2. Press Hz / NCV button once for AC current frequency without connecting the test

lead to Terminals.

3. Press Hz / NCV button once to enter the Frequency Mode for DC voltage frequency

after connecting the test lead to Terminals;

4. Touch the probes to the desired test points of the circuit;

5. Read the measured frequency value on the display.

(7) Measure NCV

1. Press Hz / NCV over 2 seconds to toggle to the NCV Mode;

2. Hold the product and move it around, the built-in beeper will beep when the inner

sensor detects AC voltage nearby. The stronger the voltage is, the quicker the

beeper beeps.

3.Put the red probe into the

terminal, then use the black probe to touh the

Live line and Neutral line of the Main supply. You can judge the L-line or N-line by

the beeps, If you can hear the strong beeps,this is the L-line, or it's a N-line.

(8) Measure Inrush Current
1. Turn power on, pull out the probes and press HOLD twice to toggle to Inrush Current Mode, the
display will show "INRUSH"; 2. Push the jaw release and center the wire within the clamp jaws. The wire should
be in the marked position to keep measurement accuracy; 3. Turn on the engine or motor equipment, and the product will capture the
maximum current within 100ms when motor is starting; 4. Read the measured temperature on the display.

(9) Peak Hold
1. Turn power on, and press HOLD twice after connecting the test lead to Terminals to toggle to Peak Hold Mode, the display will show "PEAK HOLD";
2. Touch the probes to the desired test points of the circuit; 3. Read the measured voltage value on the display.

(10) Auto Power Off
1. The product automatically powers off after 15 minutes of inactivity; 2. The built-in beeper beeps 5 times 1 minute before power off; 3. To restart the product, press SELECT button; 4. To disable the Auto Power Off function, hold down the Hz / NCV button when
turning on the product, you will hear five beeps if you have successfully disabled the function.

E. General Maintenance Beyond replacing batteries and fuses, do not attempt to repair or service the product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions. (1) Do not operate the product around hot, wet, flammable, explosive or magnetic environments. (2) Clean the product with damp cloth and mild detergent; do not use abrasives or solvents. (3) Remove the input signals before you clean the product. (4) Remove the batteries if you will not use the product for a long time to prevent possible battery leak. (5) When " " is shown on the display, batteries shall be replaced as below: 1. Loosen the screw and remove the battery cover; 2. Replace the used batteries with new batteries of the same type; 3. Place the battery cover back and fasten the screw. (6) Replace fuses as above steps. Use only fuses of the same type as the original ones.
Warning 1. Do NOT exceed the "maximum value" indicated in the Specification; 2. Do NOT input voltage at the Current Mode, the Resistance Mode, the Diode
Mode, the Continuity Mode, or the Temperature Mode; 3. Do NOT use the product when the batteries or the battery cover is not placed
properly; 4. Turn off the product and remove the test leads from the test points before
changing batteries or fuses.

F. Troubleshooting If your product do not function as normal, the following steps may help you. If the problem still cannot be solved, please contact your dealer.

Problem Display Malfunction
Symbol No current input

Possible Reason Low battery; replace batteries Replace batteries Replace fuse

-5-

-6-

-7-

LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alternation, contamination, or abnormal conditions of operation or handling. All rights reserved. Specifications are subject to change without notice.
-8-


Microsoft PowerPoint 2016 3-Heights(TM) PDF Optimization Shell 5.9.1.5 (http://www -tools.com)