User Manual for PCE Instruments models including: PCE-CMM 5 CO2 Analyser, PCE-CMM 5, CO2, Analyser
User Manual User manuals in various languages (français, italiano, español, português, nederlands, türk, polski, русский, 中文) can be found by using our product search on: www.pce-instruments.com Last change: 25 January 2021 v1.0 h
User Manual. User manuals in various languages (français, ... Damage or injuries caused by non-observance of the manual are excluded from our liability and.
© PCE Instruments PCE-CMM 5 CO2 analyser User Manual User manuals in various languages (français, italiano, español, português, nederlands, türk, polski,
File Info : application/pdf, 9 Pages, 332.17KB
DocumentDocumentEnglis h User Manual PCE-CMM 5 CO2 analyser User manuals in various languages (français, italiano, español, português, nederlands, türk, polski, , ) can be found by using our product search on: www.pce-instruments.com Last change: 25 January 2021 v1.0 © PCE Instruments Contents 1 Safety notes ........................................................................................... 1 2 Device description ................................................................................ 2 2.1 Front and back ................................................................................................................. 2 2.2 Display ............................................................................................................................. 3 3 Technical specifications ...................................................................... 4 4 Delivery scope ....................................................................................... 4 5 Operating instructions ......................................................................... 4 5.1 Switch on the device ........................................................................................................ 4 5.2 Switch off the device ........................................................................................................ 4 5.3 Toggle view...................................................................................................................... 4 5.4 CO2 traffic light function ................................................................................................... 4 5.5 Settings ............................................................................................................................ 5 5.6 Automatic calibration ........................................................................................................ 5 5.7 Charge the meter ............................................................................................................. 5 6 Warranty................................................................................................. 6 7 Disposal ................................................................................................. 6 © PCE Instruments 1 Safety notes Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty. · The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter. · The instrument may only be used if the environmental conditions (temperature, relative humidity, ...) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture. · Do not expose the device to shocks or strong vibrations. · The case should only be opened by qualified PCE Instruments personnel. · Never use the instrument when your hands are wet. · You must not make any technical changes to the device. · The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents. · The device must only be used with accessories from PCE Instruments or equivalent. · Before each use, inspect the case for visible damage. If any damage is visible, do not use the device. · Do not use the instrument in explosive atmospheres. · The measurement range as stated in the specifications must not be exceeded under any circumstances. · Non-observance of the safety notes can cause damage to the device and injuries to the user. · Do not cover the back of the meter as this may cause malfunction. We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual. © PCE Instruments 1 2 Device description 2.1 Front and back 1. On/off key 2. Right key 3. Left key 4. Micro USB charging socket © PCE Instruments 2 2.2 Display Figure 1 Standard view Figure 2 Graph view © PCE Instruments 3 3 Technical specifications Measurement range CO2 Accuracy Resolution CO2 sensor Measurement range humidity Accuracy Resolution Display Sampling rate Environmental conditions Power supply Battery life Charging time Dimensions Weight 4 Delivery scope 1 x CO2 analyser PCE-CMM 5 1 x USB charging cable 5 V / 2 A 1 x user manual 5 Operating instructions 400 ... 5000 ppm CO2 ±75 ppm or ±5 % of rdg. (the higher value applies) 1 ppm NDIR 20 ... 95 % RH ±4 % RH 1 % RH 4.3" LC display 1.5 s -10 ... 50 °C / 20 ... 85 % RH 3.7 V Li-Ion battery 3000 mAh 5 V micro USB 6 h 2 h 145 x 78 x 97.2 mm 210 g 5.1 Switch on the device When the CO2 monitor is off, press and hold the on/off key for 3 seconds to turn on the meter. 5.2 Switch off the device When the power is on, press the on/off key for 3 seconds to switch off the meter. 5.3 Toggle view When the unit is switched on, all measured values are displayed as numerical values. Furthermore, the CO2 meter shows the air quality status in a green-yellow-red status lamp. Use the arrow keys (left / right) to switch to the graph. The graph shows the course of the CO2 content of the last 5 h after switching on. 5.4 CO2 traffic light function The CO2 monitor has a status lamp display (CO2 traffic light). The limit values for colour changes are as follows: Air quality Good OK Poor CO2 content 400 ... 800 ppm 800 ... 1200 ppm 1200 ... 5000 ppm Colour Green Yellow Red © PCE Instruments 4 5.5 Settings Press the on/off key twice in quick succession to open the settings menu . 5.5.1 Setting the date (DATE) Use the left and right keys to change the highlighted value for day, month, year. Confirm the setting with the on/off key. 5.5.2 Setting the time (TIME) Use the left and right keys to change the highlighted numeric value for hour and minute. Confirm the setting with the on/off key. 5.5.3 Select unit (UNIT) You can switch between °C and °F using the left and right keys. Confirm the setting with the on/off key. 5.5.4 Set temperature offset (TEMP) To set an offset for the measured temperature value, use the left and right keys to change the numerical value. Confirm the setting with the on/off key. 5.6 Automatic calibration The PCE-CMM 5 has the integrated self-correcting ABC algorithm (Automatic Baseline Correction) for automatic adjustment of the baseline value. This calibration is performed once a day. For this, the PCE-CMM 5 requires a regular supply of fresh air. The measured value is adjusted automatically. The ABC function is permanently switched on (cannot be switched off) and adjusts the baseline value at regular intervals when the CO2 level is low. Do not use this meter in a closed environment where the CO2 concentration remains relatively high. This would adversely affect the selfcorrection of the meter. 5.7 Charge the meter When the battery icon on the display indicates that the battery is discharged, the PCE-CMM 5 must be charged via the micro USB port. To do this, use the supplied USB charging cable or a USB power supply with 5 V / 1000 mA. Please note that it may take at least 2 hours to recharge the battery to 100 %. Note: Charging via a 500 mA port on the computer is not possible. © PCE Instruments 5 6 Warranty You can read our warranty terms in our General Business Terms which you can find here: https://www.pce-instruments.com/english/terms. 7 Disposal For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments. © PCE Instruments 6 PCE Instruments contact information Germany PCE Deutschland GmbH Im Langel 4 D-59872 Meschede Deutschland Tel.: +49 (0) 2903 976 99 0 Fax: +49 (0) 2903 976 99 29 info@pce-instruments.com www.pce-instruments.com/deutsch United Kingdom PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF Tel: +44 (0) 2380 98703 0 Fax: +44 (0) 2380 98703 9 info@pce-instruments.co.uk www.pce-instruments.com/english The Netherlands PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31 (0)53 737 01 92 info@pcebenelux.nl www.pce-instruments.com/dutch United States of America PCE Americas Inc. 1201 Jupiter Park Drive, Suite 8 Jupiter / Palm Beach 33458 FL USA Tel: +1 (561) 320-9162 Fax: +1 (561) 320-9176 info@pce-americas.com www.pce-instruments.com/us France PCE Instruments France EURL 23, rue de Strasbourg 67250 Soultz-Sous-Forets France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 info@pce-france.fr www.pce-instruments.com/french Italy PCE Italia s.r.l. Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano Capannori (Lucca) Italia Telefono: +39 0583 975 114 Fax: +39 0583 974 824 info@pce-italia.it www.pce-instruments.com/italiano China PCE (Beijing) Technology Co., Limited 1519 Room, 6 Building Zhong Ang Times Plaza No. 9 Mentougou Road, Tou Gou District 102300 Beijing, China Tel: +86 (10) 8893 9660 info@pce-instruments.cn www.pce-instruments.cn Spain PCE Ibérica S.L. Calle Mayor, 53 02500 Tobarra (Albacete) España Tel. : +34 967 543 548 Fax: +34 967 543 542 info@pce-iberica.es www.pce-instruments.com/espanol Turkey PCE Teknik Cihazlari Ltd.ti. Halkali Merkez Mah. Pehlivan Sok. No.6/C 34303 Küçükçekmece - stanbul Türkiye Tel: 0212 471 11 47 Faks: 0212 705 53 93 info@pce-cihazlari.com.tr www.pce-instruments.com/turkish Hong Kong PCE Instruments HK Ltd. Unit J, 21/F., COS Centre 56 Tsun Yip Street Kwun Tong Kowloon, Hong Kong Tel: +852-301-84912 jyi@pce-instruments.com www.pce-instruments.cn © PCE Instruments 7