Instruction Manual for Emergency Lights Co models including: NYC-EX-COMBO, New York Combination Emergency Exit Light, NYC-EX-COMBO New York Combination Emergency Exit Light, Emergency Exit Light
SUNLITE Surface 04306-SU Mount 2-3 Head Universal Exit-Emergency Light – BulbAmerica
File Info : application/pdf, 2 Pages, 780.00KB
DocumentDocumentSALE on Sunlite @ www.BulbAmerica.com take additional 5% Off with coupon code 5PDF INSTALLATION INSTRUCTIONS FOR NEW YORK COMBINATION EMERGENCY EXIT LIGHT IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS rs. ly cords touch hot surfaces. gas or electric heaters. rely in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel. The use of accessory equipment and replacement parts not recommended by the manufacturer may cause an unsafe condition. for other than its intended purpose. The AC voltage rating of this equipment is specified on the product la ny other voltage. SAVE THESE INSTRUCTIONS! IMPORTANT: re-lamping use only lamps specified by the manufacturer. Using other lamp types may result in transformer damage or cause unsafe conditions. ry in this unit may not be fully charged. After electricity is hooked up to the unit, let the battery charge up for at least 24 hours. Then normal operation of this unit should then take effect. INSTALLATION: Back Mounting 1. Slide out the front exit panel face plate and lens/ filter by removing the screw on the bottom of the unit. 2. Remove internal metal reflector plate by removing the (2) screws. rmine which mounting holes will be used to mount the fixture to J-BOX and then punch out proper K/Os from the K/O pattern on the back panel of the housing. 4. There ar f the unit. These holes must be used when the unit is mounted to the wall. 5. Connect AC supply wires to fixture input wires. Black is for 120V; Red is for 277V; White is for Neutral. 6. Connect the Red and Blue leads coming from the Circuit board to the battery terminals. Red lead would be connected to the positive terminal and Blue lead to the negative terminal. 7. Replace the internal metal reflector and secure unit with the (2) screws. 8. Reinsert the front exit panel and red lens/ filter and secure with screw. OPTION: The package inc Nr f required this head could be mounted in between the two existing heads on the unit. This could be done before, during or after the unit's installation. The procedure is described in the following steps. 1. Punch out the square mounting hole on the top of the unit. 2. Mount the head securely with the included nut (Fig. 1). 3. Connect the yellow and violet wires coming from the circuit board (labeled `remote wires') to the yellow and violet wires on the lamp head using wire nuts or any other prescribed method. SALE on Sunlite @ www.BulbAmerica.com take additional 5% Off with coupon code 5PDF OPERATION: 1. 2. 3. The automatic charger will return into action, charging the battery and trying to maintain it in a fully charged state. NOTE: Allow the battery to charge for a minimum of 24 hrs after installation or after a power failure before conducting a 90-minute CAUTION: This equipment is furnished with a sophisticated solid state transfer switch which will automatically disconnect the emergency lights from the battery if the battery has been discharged to the end of its useful output. WARNING: Unused wires must be capped using enclosed wire nuts. MAINTENANCE: CA ways turn OFF AC power to the equipment before servicing. Servicing should be performed only by a qualified service technician. Only manufactur RO replacement parts must be used. 1. BA R : The battery supplied with this unit requir R ever it should be tested periodically (see replaced when it no longer operates the connected fixtures for the complete duration of a 30-second or expectancy of 5-7 yrs when used in a normal ambient temperature of 72º F. 2. O replace lamps as and when required. TESTING: Paragraph 31-1.3.7 of NFP requires that all emergency lighting equipment be functionally tested every 30 days for a minimum of 30 seconds and tested annually for full 90-minute duration. Written records of the testing are to be kept for examination by the authority having jurisdiction. TROUBLESHOOTING: 1. The emergenc OT operate and: a) charge indicator light is OFF - Check that the circuit breaker for AC supply is ON. b. f the charge indicator light is ON: - Check that the battery is properly connected. f remote lamps are connected to the equipment, then turn OFF the AC supply and disconnect the remote circuit wires from the equipment. Turn ON the AC supply and depress the test switc f the local lamps (mounted on the equipment itself) come ON, then check the remote circuit for short or overload condition and correct as required. Reconnect the circuit wires and restore AC power. f the local lamps don't turn ON after disconnecting the remote circuit wires, then replace battery. rgency lights ar ry might not be fully charged. Allow battery to recharge for 24 hours and then re-test. 3. Remote lights are dim - Remote wire size is too small causing excessive voltage drop (more than the permitted 5%) and thus causing the lamps to illuminate with less intensity. R f TA for more information. NOTE: Please contact factory for help with other types of issues. BOAR 277 VO T 120 VO T ACK COMM TRANSF BU RR BOAR T OW T OW T OW + - BA R P P To Remote P AC ON TC NOTE: P T AN N Star washer Nut Figure 1