Keithley Model 2306-LAN Firmware Release Notes

Model: 2306-LAN

Company: Keithley Instruments, A Tektronix Company

Address: 28775 Aurora Road, Cleveland, Ohio 44139

Contact: 1-800-833-9200, tek.com/keithley

Overview

Version D04 is the initial firmware release for the Model 2306-LAN.

Note: Use this procedure only for the 2306-LAN. Do not use this configuration procedure for the Series 2300 models 2302, 2303, 2306, or 2308.

Firmware Status

Firmware Upgrade Instructions

Download the 2306-LAN Configuration Tool from the Product Support and Downloads web page. This tool provides the interface needed to upgrade the firmware and set up the 2306-LAN IP address, netmask, gateway, and port from a computer. Once the executable file for the configuration tool has been downloaded, follow the steps below to install and use the tool.

You will also need to download the firmware you want to install on your Model 2306-LAN instrument from the Product Support and Downloads web page.

For LAN configuration information, see LAN configuration.

Note: Use this procedure only for the 2306-LAN. Do not use this configuration procedure for the Series 2300 models 2302, 2303, 2306, or 2308.

Connect a LAN cable from your computer to the LAN port on the rear panel of the 2306-LAN. Set the computer IP address to 192.168.0.3 and the Subnet mask to 255.255.255.0. Set the instrument IP address to 192.168.0.2.

To use the LAN Configuration Tool:

  1. Double-click the 2306-LAN Configuration Tool.exe file.
  2. Click "Firmware Upgrade" (see Figure 1).
Figure 1: 2306-LAN Firmware Upgrade. A screenshot of the "2306-LAN Configuration Tool" window, showing input fields for Local IP, Device IP, Model, and Version, along with buttons for "Scan Devices", "Firmware Upgrade", "Select Fw", and "Fw Upgrade". The tool version is 1.0.0.
  1. Select "Local IP" to your computer IP address (192.168.0.3).
  2. Click "Scan". The IP information of the instrument is displayed (the default IP is 192.168.0.2).
  3. Click "Select Fw" to choose the firmware file saved on your computer.
  4. Click "Fw Upgrade" to proceed.

You will see the word "SUCCESS" when the upgrade is complete.

Figure 2: Upgrade LAN Firmware. A screenshot of the "Upgrade" window within the "2306-LAN Configuration Tool". It shows the Local IP as 192.168.0.3, Device IP as 192.168.0.2, Model as 2306LAN, and Version as D04. Buttons include SCAN, Select Fw, and Fw Upgrade. A log displays the upgrade process details and completion, with a prominent "SUCCESS" message.

Product Support

Contact product support via the Product Support and Downloads web page if you have any problems or questions. Alternatively, you can arrange to have Keithley Instruments upgrade your firmware at the factory by calling your local Keithley Instruments support office.

Models: 2306-LAN Battery Simulating DC Power Supply, 2306-LAN, Battery Simulating DC Power Supply, Simulating DC Power Supply, DC Power Supply, Power Supply, Supply

PDF preview unavailable. Download the PDF instead.

077174100 2306-LAN FW RN Sep 2021 2306-LAN-FRP-D04 Adobe PDF Library 21.5.92

Related Documents

Preview Keithley KickStart Software Release Notes: Version History and Updates
Explore the evolution of Keithley's KickStart Instrument Control Software with detailed release notes, including new features, bug fixes, and supported instrument models from version 1.0.0 to 1.9.6.
Preview Keithley Series 2600B Firmware Release Notes
This document provides detailed release notes for the Keithley Series 2600B System SourceMeter Instruments firmware, outlining critical fixes, enhancements, and noncritical fixes across various versions from 3.0.1 to 3.4.0.
Preview Keithley KickStart Instrument Control Software Version 2.5.0 Release Notes
Official release notes for Keithley KickStart Instrument Control Software version 2.5.0, detailing supported hardware models, operating systems, installation procedures, software history, known issues, enhancements, usage notes, and resolved issues.
Preview Measuring Electrical Resistivity of Insulating Materials with Keithley Equipment
Application note detailing how to measure the electrical resistivity of insulating materials using Keithley 6517B Electrometer and 8009 Test Fixture, covering surface and volume resistivity, test methods, and software automation.
Preview Keithley 4200A-SCS Parameter Analyzer Quick Start Guide
A quick start guide for the Keithley 4200A-SCS Parameter Analyzer, detailing safety precautions, unpacking, installation, operation, and basic troubleshooting for semiconductor device characterization.
Preview Keithley Model 4288-1 Single-Unit Rack-Mount Kit Installation Guide
Detailed installation instructions for the Keithley Model 4288-1 Single-Unit Rack-Mount Kit. Covers parts, tools, safety precautions, and step-by-step assembly for mounting a half-rack instrument in a standard 19-inch rack.
Preview Keithley DAQ6510 Data Acquisition and Multimeter System Reference Manual
Comprehensive reference manual for the Keithley DAQ6510 Data Acquisition and Multimeter System, detailing its features, operation, installation, and command set for advanced measurement and control applications.
Preview Keithley 4200A-SCS Setup and Maintenance User's Manual
Comprehensive user's manual for the Keithley 4200A-SCS Parameter Analyzer, covering setup, installation, configuration, maintenance, and system administration for semiconductor characterization.