Instruction Manual for COSA models including: FE-AA01-A CX10-5B-56, FE-AA03-B CX10-5B-46, FE-AA02-A CX10-5B-40, FE-AA0 Series Ceiling Fan, FE-AA0 Series, Ceiling Fan, Fan

3. Cosa CX10 Manual V2 241105

One moment, please...

3. Cosa CX10 Manual V2 241105 - alphamalaysia.com

Instruction Manual Version: 2024 V2 Ceiling Fan FE-AA01/A CX10-5B/56 FE-AA03/B CX10-5B/46 FE-AA02/A CX10-5B/40


File Info : application/pdf, 8 Pages, 2.50MB

PDF preview unavailable. Download the PDF instead.

3. Cosa CX10 Manual V2 241105 1
Instruction Manual
Ceiling Fan
FE-AA01/A CX10-5B/56 FE-AA03/B CX10-5B/46 FE-AA02/A CX10-5B/40
Version: 2024 V2

Table of Contents

Item

Page No.

1. Safety Precautions ................................................................................................ 1 - 2

2. Parts & Accessories .............................................................................................. 3

3. Installation Instruction ............................................................................................ 4 - 7

4. Transmitter Learning Process ................................................................................ 8

5. Transmitter Assembly & Operation ........................................................................ 9

5. Power Supply Connection ...................................................................................... 10

6. Circuit Diagram ...................................................................................................... 11

7. Maintenance .......................................................................................................... 12

8. Technical Specifications ........................................................................................ 12 - 13

9. Customer Service Centre ...................................................................................... 13

Safety Precaution
Warning
Installation and maintenance work shall only be performed by qualified persons, familiar with local code and regulation, and experienced with this type of appliance.
All field wiring must be installed in accordance with the national wiring regulation.
Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.
The appliance must be permanently connected to the electricity supply through a double pole switch having a contact separation of at least 3mm in all poles.
The unit must be GROUNDED to prevent possible hazard due to insulation failure. The earth wire is approximately 60mm longer than safety wire. This is to ensure at the event whereby the suspension system fails, the (L) and (N) wire will break leaving the fan remain earthed to prevent electrocution.
Tighten the blade firmly using a screw driver. Blades that are detached from the unit during operation will cause serious injuries and property damages.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliances.
Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure that the blade is fully static before doing any maintenance work.
1

Safety Precaution
STOP using the ceiling fan when any abnormality or failure occurs. If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.
CAUTION
Please take note of the following important points when installing.
The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan.
The mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.
The fan is to be installed so that the blades are more than 2.5m above the floor.
Safety cord should not be longer than the earthing conductor. Should failure of the suspension system occur, the supporting of the fan must not rely on the earthing conductor.The earthing terminal in the fan assembly should be such that should any part of the suspension system fall off, the body of the fan assembly shall effectively earthed.
Ensure that the unit's panel is closed after service or installation. Unsecured panels will cause the unit to operate noisily.
Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places.
Before turning off the power supply set the remote controller's ON/OFF switch to the "OFF" position. If this is not done, the unit's fans will start turning automatically when power resumes, posing a hazard to service personnel or the user.
Do not operate any heating apparatus too close to the ceiling fan unit or use in room where mineral oil, oil vapour or oil steam exist, this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction. Avoid the ceiling fan unit from exposing to direct sunlight, this may cause degradation of plastic material as a result of excessive heat and UV radiation.
Ensure the colour of wires of the outdoor unit and the terminal markings are same to the indoors respectively.
Do not use joined and twisted wires for incoming power supply.
Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling fan.
The fan suspension system and blade screw tightening shall be examined yearly.
Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.
Torque value for screw/bolts for securing primary suspension system for motor is 2Nm.
2

Parts & Accessories

Canopy Coupling Cover

Motor Bracket Downrod
Bolt x 2

Rubber Pulley Assembly x 1
Blade Screw & Washer x 11

Motor Assembly Transmitter Kit

Blade x 5
AAA AAA
Battery x 2

Receiver x 1

Transmitter & Holder x 1

Wall Screw x 2

3

Installation Instruction

IMPORTANT: SWITCH OFF THE ELECTRICAL MAINS AT THE CIRCUIT BREAKER FUSE BOX.
Step 1 a. Insert the Motor Bracket Motor to the Motor Shaft. b. Route Motor wires and Safety cable through the Downrod. c. Fix the Motor Bracket and Downrod to the Motor Assembly with Bolt, Washer, Nut and
tighten them firmly then insert the Clevis Pin.
IMPORTANT : Clevis Pin MUST be inserted to prevent Nut from loosening.

a.

b.

c.

Motor Bracket

Downrod

Motor Wire & Safety Cable

Motor Shaft
Motor

Washer,

Bolt

Nut and

Clevis Pin

Step 2 a. Assemble the Canopy and Coupling Cover through the Downrod. b. Fix the Rubber Pulley Assembly to the Downrod with Bolt, Washer, Nut and tighten
them firmly, then insert the Clevis Pin.

a.

Canopy

b.

Coupling Cover

Rubber Pulley Assembly

Washer, Nut & Celvis Pin

Bolt Downrod

Installation Instruction

Step 3 a. Remove the Bolt, Clevis Pin, Nut, Washer and Rubber Pulley from the Downrod. b. Place the Rubber Pulley onto the ceiling hook. c. Fix back the Bolt, Clevis Pin, Nut and Washer.
IMPORTANT : Clevis Pin MUST be inserted to prevent Nut from loosening.

a. Bolt

Rubber Washer Nut Clevis

Pulley

Pin

b.
Rubber Pulley

Fan Hook

c.

Safety Wire

Step 4 a. Remove the Safety Wire screw and washer from the Downrod. b. Install the Safety Cable.

a.

Safety

b.

Wire

4

5

Installation Instruction

Step 5 Connect the Connectors from Fan and Receiver. Connect the wires from the receiver to House's Supply Wire. Connect Earth Wire to House Supply Earth Terminal.

House Supply Wires

Brown(L) Blue(N)

Green/Yellow(E)

Green/Yellow(E) Brown(L) Blue(N)

White White Yellow Yellow Grey Grey

Green/Yellow(E)

Step 6 Install the Blades on Motor with Blade Screw and Washer.
IMPORTANT: Assemble the Fan Blades only after the ceiling fan is mounted on the hook.

Blade Screw & Washer

Blade

Installation Instruction
Below shows a complete installation diagram.

6

7

Transmitter Learning Process
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO REGULATOR OR DIMMER SWITCH.
The receiver & transmitter is pre-programmed in factory. If you wish to control 2 or more fans using 1 transmitter, the below steps are required. DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
Step 1 a) Insert the 2 pcs of batteries (provided) into transmitter. b) Turn on the power supply (wall switch) to the fan. c) Within 30 sec., press and hold the "OFF" button for 3 sec. Once the receiver has
detected the frequency, transmitter will "Beep Beep" twice. Programming process is completed and fan is ready to use. If the fan is not responding to the transmitter, repeat Step 1b.
Press and hold for 3 sec

Transmitter Assembly & Operation

IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO REGULATOR OR DIMMER SWITCH.

Function of Transmitter
- Turn off fan. - Fan speed lowest to highest. - Natural wind, creating gentle sea-
breeze effect. - Forward/Reverse, turn anti-clockwise
or clockwise rotation. - Fan speed will decrease gradually
every 30 minutes until reach to speed 1 - Natural wind, creating gentle sea-breeze
effect. - Timer off - fan turns off after 1hr. - Timer off - fan turns off after 3hr. - Timer off - fan turns off after 6hr.

Mount the remote control holder on the wall with the screws provided.

The transmitter & receiver is incorporated with last memory function. This function stores your last setting in memory and the next time you turn on the fan, fan will operate as the last setting.

Function of Forward & Reverse

Fan must be turned on and rotating.

Press Forward/Reverse button and fan will slow down and then change direction (approx. 15 sec). When the fan is slowing down to change direction, the Fan Speed function is disabled until direction has been changed.

Forward

Reverse

Fan rotates anti-clockwise blowing

Fan rotates clockwise drawing the air

the air downwards creating the

towards the ceiling circulating the warm

wind chill effect. Suitable for hot

air downwards. This function works best

weather condition.

at low speed. Suitable for air-conditioned

condition.

8

9

Power Supply Connection

Circuit Diagram

Double Pole Switch

Power Supply

Single Pole Switch

IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO REGULATOR OR DIMMER SWITCH.

DC Motor

Earth (Green/Yellow) Grey
Yellow White

Neutral (Blue) Live (Brown) Earth (Green/Yellow)
Power Supply 220-240V~ 50Hz

Blue Brown Green/Yellow

W ANT V U MAIN PCB N
L
E

Regulator

Dimmer Switch

10

11

More than 2.5m (8' 2") 273mm (10.7")
345mm (13.5")

Maintenance
Due to the fan's natural movement, connections may get loose after period of usage. To ensure a proper and safety usage, it is highly recommended to inspect and tighten all connections every 6 months.
Cleaning Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures are as follows : 1. Use only water and mild soap. Do not use solvents, corrosive or acidic solution. 2. Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric
will scratch the surface. 3. Do not bent the blades while cleaning. At the event where blades are bent or
damage, order new set of blades from service center or dealer shop. 4. There is no need to oil the fan.

Technical Specifications

More than 1000mm

FE-AA01/A (CX10-5B/56) 1420mm (56") FE-AA03/B (CX10-5B/46) 1168mm (46") FE-AA02/A (CX10-5B/40) 1015mm (40")

Technical Specifications

Model Alt. Name No. Of Blades Fan Width Motor RPM
Voltage Motor Wattage
Nett Weight Gross Weight

FE-AA01/A CX10-5B/56
1420mm (56") 75 - 203
4W - 45W 4.7kg 5.7kg

FE-AA03/B CX10-5B/46
5 1168mm (46")
75 - 233 220-240V~ 50Hz
4W - 40W 4.3kg 5.3kg

FE-AA02/A CX10-5B/40
1015mm (40") 84 - 226
4W - 40W 4.3kg 5.3kg

12

Customer Service Centre

If you need any technical assistance or faulty report, please contact our customer service centre at :

Alpha Home Appliances Sdn. Bhd. (390258-H)

Head Office : 6, Jalan Sungai Kayu Ara 32/37, Berjaya Park, Section 32,

40460 Shah Alam, Selangor.

Tel

: 03-5740 6666

Fax : 03-5740 8220

Website : www.alphamalaysia.com

Email : info@alphamalaysia.com

Johor Bahru : 71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.

Tel

: 07-353 4833 / 4933

Fax : 07-355 4233

Melaka Tel

: 19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.

: 06-292 6292 / 6293

Fax : 06-292 6296

Ipoh

: 11, Laluan Tasek Timur 5, Taman Tasek Indra, 31400 Ipoh, Perak.

Tel

: 05-545 2282 / 547 2282

Fax : 05-547 6282

Penang Tel

: 28, Jalan Icon City, Icon City, 14000 Bukit Mentajam, Penang. : 04-506 2366 / 2066 / 2566 Fax : 04-506 2966

Pahang Tel

: A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.

: 09-516 5226

Fax : 09-513 9226

13



References

Adobe PDF library 17.00 Adobe Illustrator(R) 24.0