Installation Guide for Danfoss models including: 080G5040 IPS 8 Extension Module, 080G5040, IPS 8 Extension Module, Extension Module, Module
080R9501 110 080R9501 Installation guide IPS 8 extension module | 080G5040 Type MCX08M2 Introduction The IPS 8 extension module is always connected via CANbus, back to IPS with MCX15B2. The IPS 8 extension module includes 8 Digital Output which then give up to 8 additional Purge Points. 080R9501 AN508522055668en-000101 Reference: For details please refer data sheet Programmable controller, 8 relays, type MCX08M2 Applications More info IPS 8 with MCX15B2 controller Accessory package allowing extra Purge Points IPS 8 with MCX15B2 controller - Field connected solenoid coils for purge points is powered from IPS main E-panel Accessory package Includes - MCX08M2 w/SW IPS 8 extension module Hardwired to field connected field coils CANBus Hardwired to field connected field coils 8 purge points Dimension IPS 8 8 purge points LCD display 140 © Danfoss | Climate Solutions | 2024.12 63 AN508522055668en-000101 | 1 084H5001, IPS 8, CE, 230 V AC, 1ph, 50Hz 084H5002, IPS 8, 230 V AC, 1ph, 60Hz Bottom board +24 V AC/DC CAN H CAN L CAN GND MCX15B2 IPS 8, Air Purger IPS 8 Control box CAN bus 45 6 8 XT4 XT4 XT4 XT4 CAN H CAN L CAN GND BR WH GN SCH 29.5 29.6 29.7 29.8 XM4 XM4 XM4 XM4 084H5003, IPS 8, UL 230 V AC, 1ph, 60Hz MCX08M2 - BOTTOM PP9 EV PP10 EV PP11 EV PP12 EV PP13 EV PP14 EV PP15 EV PP16 EV Danfoss 80G8036B Connectors Power supply connector CAN connector Digital output 1-8 connector 2 | AN508522055668en-000101 Type 2 way screw plug-in connector type 4 way screw plug-in connector type 4 way screw plug-in connector type Dimensions · pitch 5 mm · section cable 0.22.5 mm · pitch 5 mm · section cable 0.22.5 mm · pitch 5 mm · section cable 0.22.5 mm © Danfoss | Climate Solutions | 2024.12 General features Features Power supply Plastic housing Ball test Operating conditions Storage conditions Integration Index of protection Period of electric stress across insulat- ing parts Resistance to heat and fire Immunity against voltage surges Software class and structure Description 2060 V DC and 24 V AC ± 15% 50/60 Hz SELV Maximum power consumption: 10 W, 17 V A Insulation between power supply and the extra-low voltage: functional DIN rail mounting complying with EN 60715 Self extinguishing V0 according to IEC 60695-11-10 and glowing / hot wire test at 960 °C according to IEC 60695-2-12 125 °C according to IEC 60730-1 Leakage current: 250 V according to IEC 60112 CE: -20T60 / UL: 0T55, 90% RH non-condensing -30T80, 90% RH non-condensing In Class I and / or II appliances IP40 only on the front cover Long Category D Category II Class A Digital outputs Type Num Specifications Relay 8 Insulation between relay: functional Insulation between relays and the extra-low voltage parts: reinforced Total current load limit: 32 A C1-NO1, C2-NO2 High inrush current (80 A20 ms) normally open contact relays 16 A Characteristics of each relay: · 10 A 250 V AC for resistive loads - 100.000 cycles · 3.5 A 230 V AC for inductive loads - 230.000 cycles with cos(phi) = 0.5 C5-NO5, C6-NO6 Normally open contact relays 8 A Characteristics of each relay: · 6 A 250 V AC for resistive loads - 100.000 cycles · 4 A 250 V AC for inductive loads - 100.000 cycles with cos(phi) = 0.6 Option for code 080G0314: · SPST SSR type · 0.5 A 250 V AC resistive load (115 W) C3-NO3-NC3, C4-NO4-NC4, C7-NO7-NC7, C8-NO8-NC8 Changeover contacts relay 8 A Characteristics of each relay: · 6 A 250 V AC for resistive loads - 100.000 cycles · 4 A 250 V AC for inductive loads - 100.000 cycles with cos(phi) = 0.6 © Danfoss | Climate Solutions | 2024.12 AN508522055668en-000101 | 3 IPS 8 extension module - Main screen Serial setting: ID: 125 - expansion module address 125 ComS: 34800 - expansion module baud rate 34800 IPSB ID: 1- main controller address 1 IPS 8 with MCX15B2 controller - settings All settings are configured in the main controller A. How to activate Expansion module? «Main Menu» «Start» «Main switch OFF» «Main menu» «Login» «Password 200» «General» «Expansion settings» «Yes» «Main Menu» «Start» «Main switch OFF» B. How to change the number of purge points? «Main Menu» «Start» «Main switch OFF» «Main menu» «Login» «Password 200» «Parameters» «Unit config» «Valve settings» «Max PP ...» «Main Menu» «Start» «Main switch OFF» C. How to reconfigure Digital output? For example: DO23 as valve 16. «Main Menu» «Start» «Main switch OFF» «Main menu» «Login» «Password 200» «Input/output «I/O Configuration» «Valve settings» «Digital output «Digital output 23» «Valve 16» «Main Menu» «Start» «Main switch OFF» © Danfoss | Climate Solutions | 2024.12 AN508522055668en-000101 | 4Danfoss A/S GPL Ghostscript 10.04.0