User Guide for EnGenius models including: EWS2910P-FIT Fit L2 Managed 55W PoE Switch Access Point, EWS2910P-FIT, Fit L2 Managed 55W PoE Switch Access Point, L2 Managed 55W PoE Switch Access Point, PoE Switch Access Point, Switch Access Point, Access Point, Point
30 nov 2022 — 8 10/100/1000 Base-T GbE Ports. • Full-featured Layer 2 plus switching. • 802.3at/af PoE ready on all ports with 55W PoE budget.
File Info : application/pdf, 10 Pages, 1.70MB
DocumentDocumentQuick Start Guide EWS2910P-FIT Quick Start Guide Introduction This Quick Start Guide is designed to guide you through the installation of the Fit L2+ managed 55W PoE+ switch access point, model EWS2910P-FIT, including hardware mounting and configuration. Package Contents Model: EWS2910P-FIT · 8 10/100/1000 Base-T GbE Ports · Full-featured Layer 2 plus switching · 802.3at/af PoE+ ready on all ports with 55W PoE budget · Setup in minutes with app-based step by step instructions · Quick-scan device register, remote monitoring and troubleshooting · Real-time system metrics, analytics and remote configurations EnGenius Fit PoE Switch Wall Mount Kit Power Adapter Power Cord Rubber Feet Cushion Product Card EWS2910P-FIT Quick Start Guide System Requirements Web Browser · Google Chrome (57.0.2987.110 and later) · Microsoft Edge (80.0.361.103 and later) · Mozilla Firefox (52.0 and later) Reset Button: Reset to default: Press and hold the reset button on the PoE adaptor for over 60 seconds, and the LED (PWR) will go off and on.. Then, the device will be reset to factory default settings. LED System LEDs LED RJ45:PoE/Speed LED RJ45:Link/Act LED SFP LED: Link/Act EWS2910P-FIT Quick Start Guide LEDs LOCATION System Copper Port SFP Slot LED INDICATOR COLOR Power Green Fault PoE Max LAN Mode PoE Mode LAN Mode PoE Mode Link/Act Link/Act Amber Amber Green Green Green Amber Off Green Amber Off Green Amber Off Green STATUS Flashing Solid On Light Off Solid On Light Off Solid On Light Off Solid On Solid On Solid On Solid On Light Off Solid On Solid On Light Off Flashing Solid On Light Off Flashing Solid On Light Off DESCRIPTION Before system boot Power on Power off Any fault Normal When the total Poe output power archive max power budget System still have spare power for new PD Select LED Mode to Ethernet Mode Select Led Mode to PoE Mode Speed 1000 Mbps Speed 100 Mbps Speed 10 Mbps Power feeding Error condition Now Power Feeding Link Transmit or receive on this port No link Link Transmit or receive on this port No link EWS2910P-FIT Quick Start Guide Hardware Mounting The access point can be mounted on the Wall and Pole, and please perform the steps for the appropriate installation. Rack Mount 1. Determine where the Ethernet Switch will be placed and mark the location on the surface for the two mounting holes. Use the appropriate drill bit to drill two 8.1mm diagram and 26mm-deep holes on the marks. 2. Screw the Anchors into the holes until they are flush with the wall; screw the included Screws into the Anchors but leave the screw head sticking out so you can hang the Ethernet Switch on it. Anchors Screws Powering EnGenius Fit Switch EnGenius Fit Switch can be powered by following: · Power Adapter EWS2910P-FIT Quick Start Guide Connecting to a Power Cord Connect the Power Cord cable from the EnGenius Fit PoE+ Switch EWS2910P-FIT AP directly to the Wall Outlet. Wall Outlet EnGenius Fit PoE Switch Power Adapter Management Plane EnGenius Fit provides flexible options to manage your devices based on your network planning and deployment. Option A: Cloud Management Option B: On-Premises Management Option C: Standalone Configuration Cloud Management Manage and monitor the Switch through the FitXpress Platform with a mobile app or through the web portal. FitXpress App (iOS/ Android) Download the FitXpress mobile app App Store click here Download the FitXpress mobile app Google Play click here Scan to download FitXpress app On-Premises Management If you want to manage the device in on-premises mode, you need an onsite management station running the FitController connected to the same Layer 2 network. FitController FitController is a custom-built appliance with optimized network management software installed to ease onsite deployment without manual server configurations. EWS2910P-FIT Quick Start Guide Standalone Configuration Using your computer, you can connect to the same network (subnet) as the Switch and use the web browser to access the device's local web GUI page for configurations whenever the device is set to Standalone mode. Option A: Cloud Management with FitXpress Step 1: Connecting Ethernet Connect the Ethernet cable from the EnGenius Fit Switch directly to the DHCP-enabled network and make sure the Switch can reach the Internet. Internet DHCP-Assigned IP Gateway/Router/ Network Switch Step 2: Register Device You can register the access point with the FitXpress app. 1. Open the FitXpress mobile app and create an account. 2. Login and go to the Devices section. Click the Add (+) button. 3. Scan the QR code on the back of the device via the app. EnGenius Fit PoE Switch Scan QR-code for device registration EWS2910P-FIT Quick Start Guide 4. If the camera successfully scans the QR code, the app will display the device information. You can tap "Register" to complete the registration. Step 3: Connect to FitXpress Once the device is powered on and ready to connect to the Internet, the PWR LED will stay Solid On, which means the device is now connected to the FitXpress platform. It will automatically download the default configuration settings from FitXpress for automated provisioning. When the Switch is connected to the FitXpress Platform for the first time, it will automatically check the latest firmware version available. If a firmware upgrade is required, it might take 8~10 minutes to complete the process. All LED indicators will be Flashing (0.5 sec) till the process is finished. Step 4: Manage with the FitXpress Log in to the FitXpress app to configure detailed settings and monitor your devices. EWS2910P-FIT Quick Start Guide Option B: On-premises Management with FitController Step 1: Connecting Ethernet Connect the Ethernet cable from the EnGenius Fit Switch directly to the DHCP-enabled network, which is the same Layer-2 network as FitController. Internet Gateway FitController EnGenius Fit PoE Switch Step 2: Log in to the FitController Launch your web browser to access the login page of FitController and create an account. Enter the email address and password that you created and click Sign In. The FitController default IP address in DHCP client mode will get an IP address (e.g. X.X.X.X:8080) from the DHCP server. If FitController cannot get an IP address from the DHCP server, the default IP address will be 192.168.1.250:8080. EWS2910P-FIT Quick Start Guide Step 3: Register Device and Assign to Network 1. Go to the system > Inventory page and click "Register Device (+)". 2. FitController will list all EnGenius Fit devices discovered from the same L2 network in the Pending Approval section. Select the device and Click "Register" to add to inventory. You can also tap "Manually" tab and register Fit device by entering Serial Number. 3. From the Inventory page, Select the newly added device and click "Assign to Network" to add the device to your personalized network. Step 4: Pairing the Device 1. Go to access point or switch list. 2. Select the newly added device and click "Pairing" to allow the access point to build an encrypted connection between the device and FitController. Step 5: Manage with FitController Navigate to the left side menu to configure & manage your network and view network statistics using the FitController management interface. EWS2910P-FIT Quick Start Guide Option C: Standalone Configuration Step 1: Access to Local Web 1. Connect the Ethernet cable from the laptop directly to the EnGenius Fit Switch. 2. Under your web browser, enter the URL: http://EnGenius.local or http://192.168.0.239 to access the device's user interface. 3. Use the default login credential (ID/PWD: admin/password) to log in to the device's local web page. Step2: Configure and Manage the Device After logging into the device's local web page, navigate to the left side menu to configure and manage the Switch accordingly. How to Change Management Mode? EnGenius Fit devices support versatile network management methods, but the device can only be managed under one management mode at a time - either FitXpress, FitController, or Standalone. Therefore, you need to reset the device before changing to a different management mode. Then follow Quick Start Guide instructions for the device onboarding. EnGenius Technologies | 1580 Scenic Ave. Costa Mesa, CA 92626 Email: partners@engeniustech.com | Website: engeniustech.com Version:11/2022 Maximum data rates are based on IEEE 802.11 standards. Actual throughput and range may vary depending on distance between devices or traffic and bandwidth load in the network. Features and specifications subject to change without notice. Trademarks and registered trademarks are the property of their respective owners. For United States of America: Copyright ©2022 EnGenius Technologies, Inc. All rights reserved.