User Guide for valuetesters models including: TKW-40-PF Line Paddle Wheel Flow Meter Sensor, TKW-40-PF, Line Paddle Wheel Flow Meter Sensor, Wheel Flow Meter Sensor, Flow Meter Sensor, Meter Sensor
File Info : application/pdf, 9 Pages, 1.09MB
DocumentDocumentTruflo® -- TKW | TK3W Series (Blind) In-Line Paddle Wheel Flow Meter Sensor Quick Start Manual Read the user's manual carefully before starting to use the unit. Producer reserves the right to implement changes without prior notice. 2F4i-n05d65Qu©aIclointyProPcreossdCuonctrtosls OLtdn. line at: Valuetesters.com info@valuetesters.com1 Truflo® -- TKW | TK3W Series (Blind) In-Line Paddle Wheel Flow Meter Sensor Safety Information De-pressurize and vent system prior to installation or removal Confirm chemical compatibility before use DO NOT exceed maximum temperature or pressure specifications ALWAYS wear safety goggles or face-shield during installation and/or service DO NOT alter product construction Warning | Caution | Danger Indicates a potential hazard. Failure to follow all warnings may lead to equipment damage, injury, or death. Note | Technical Notes Highlights additional information or detailed procedure. Personal Protective Equipment (PPE) Always utilize the most appropriate PPE during installation and service of Truflo® products. Pressurized System Warning Sensor may be under pressure. Take caution to vent system prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury. Please ensure that the Instruments are not to be subject to water hammer or pressure spikes! Always Pressure Test System with H2O Prior to Initial Start-Up Before installation be certain the appropriate instrument has been selected considering operating pressure, full scale pressure, wetted material requirements, media compatibility, operating temperature, vibration, pulsation, desired accuracy and any other instrument component related to the service application including the potential need for protective attachments and/or special installation requirements. Failure to do so could result in equipment damage, failure and/or personal injury. Ensure only qualified personnel are permitted to install and maintain this instrument. Pressurize System Warning WARNING Sensor may be under pressure, take caution to vent system prior to installation or removal. Failure to do so may result in equipment damage and/or serious injury. Please Ensure Full Pipe TK Series can be installed in a horizontal or vertical direction. Please ensure enough length of straight pipe to avoid turbulence that can effect readings. Min 10x Pipe Diameters Upstream 3x Pipe Diameters Downstream A Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers - max 10% Particle Size - Not to Exceed .5mm Cross Section or Length. Please do not flush the pipe after the Flow Meter is installed with compressed air this may damage the ceramic shaft and will void warranty. 2F4i-n05d65Qu©aIclointyProPcreossdCuonctrtosls OLtdn. line at: Valuetesters.com info@valuetesters.com2 Truflo® -- TKW | TK3W Series (Blind) In-Line Paddle Wheel Flow Meter Sensor Product Description The TK Series in-line plastic paddle wheel flow meter has been engineered to provide long-term accurate flow measurement in tough industrial applications. The paddle wheel assembly consists of a engineered Tefzel® paddle and micro-polished zirconium ceramic rotor pin and bushings. High performance Tefzel® and Zirconium materials have been selected due to their excellent chemical and wear resistant properties. TKW New ShearPro® Design ? Contoured Flow Profile ? Reduced Turbulence = Increased Longevity ? 78% Less Drag than Old Flat Paddle Design* *Ref: NASA "Shape Effects on Drag" TK3W Tefzel® Paddle Wheel ? Superior Chemical And Wear Resistance vs PVDF Zirconium Ceramic Rotor | Bushings ? Up to 15x the Wear Resistance vs Regular Ceramic ? Integral Rotor Bushings Reduce Wear and Fatigue Stress ShearPro® Through-Pin Design ? Eliminates Finger Spread ? No Lost Paddles ? Increased Temp. Rating ? 360° Housing Protects Rotor Finger Spread = LOST Unprotected Rotor TKW Thermal Plastic True Union Design High Impact Enclosure Bright LED Power Indication Flanged Connection 316 Stainless Steel Sanitary Connection vs. Flat Paddle vs. Competitor `A' 2F4i-n05d65Qu©aIclointyProPcreossdCuonctrtosls OLtdn. line at: TK3W 316 SS Valuetesters.com info@valuetesters.com3 Truflo® -- TKW | TK3W Series (Blind) In-Line Paddle Wheel Flow Meter Sensor Technical Specifications General Operating Range 0.3 to 33 ft/s 0.1 to 10 m/s Pipe Size Range ¼ to 4" ** DN08 to DN100 Linearity ±0.5% of F.S @ 25°C | 77°F Repeatability ±0.5% of F.S @ 25°C | 77°F Fluid Water or Chemical Liquid-Viscosity Range: .5-20 centistokes Flow Velocity 10 m/s max. Low Cut 0.3 m/s min. Operating Pressure 150 Psi (10 Bar) @ Ambient Temp |Non-Shock Range Ability 10 : 1 Response Time Real Time Flow Total Meter Range = 0~999999 ; Unit = Gallon or Liter or Ton (KL) Selectable Repeatability Range = 0.0~999.9 ; Unit = GPM or LPM or CMH Selectable Accuracy ± 0.5% of F.S. @ 25°C Wetted Materials Sensor Body PVC (Dark) | PP (Pigmented) | PVDF (Natural) | 316 SS O-Rings FKM | EPDM* | FFKM* Rotor Pin | Bushings Zirconium Ceramic | ZrO2 Paddle | Rotor ETFE Tefzel® Electrical Frequency 49 Hz per m/s nominal 15 Hz per ft/s nominal Supply Voltage 9 to 30 VDC ±10% regulated Supply Current <1.5 mA @ 3.3 to 6 VDC <20 mA @ 6 to 24 VDC Max. Temperature/Pressure Rating Standard and Integral Sensor | Non-Shock PVC 180 Psi @ 68°F | 40 Psi @ 140°F 12.5 Bar @ 20°C | 2.7 Bar @ 60°C PP 180 Psi @ 68°F | 40 Psi @ 190°F 12.5 Bar @ 20°C | 2.7 Bar @ 88°C PVDF 200 Psi @ 68°F | 40 Psi @ 240°F 14 Bar @ 20°C | 2.7 Bar @ 115°C 316 SS 200 Psi @ 180°F | 40 Psi @ 300°F 14 Bar @ 82°C | 2.7 Bar @ 148°C Operating Temperature PVC PP PVDF 316 SS 32°F to 140°F -4°F to 190°F -40°F to 240°F -40°F to 300°F 0°C to 60°C -20°C to 88°C -40°C to 115°C -40°C to 148°C Outputs NPN Pulse | Voltage | 4-20mA Display Blind | LED Indicator Standards and Approvals UL | CE | FCC | RoHS Compliant See Temperature and Pressure Graphs for more information *Optional ** ¼" - " SS Only 2F4i-n05d65Qu©aIclointyProPcreossdCuonctrtosls OLtdn. line at: Valuetesters.com info@valuetesters.com4 Truflo® -- TKW | TK3W Series (Blind) In-Line Paddle Wheel Flow Meter Sensor Wiring Diagram 4-20mA or Voltage Wire Color Description Brown + VDC Black 4-20 mA White 4-20 mA Blue - VDC Output Circuit 4-20mA or Voltage Brown Grey Black White +V Load A 4-20 mA/ 0-5 Volts Output Blue 0V Shielded NPN Pulse Output Wire Color Description Brown + VDC Black Pulse Blue - VDC NPN Pulse Output Brown +V Output Circuit Black Blue Load 0V Shielded Temperature | Pressure Graphs | Non-Shock Note: The Pressure/Temperature graphs are specifically for the Truflo® Flow Meter Sensors. During system design the specifications of all components must be considered. Min/Max Flow Rates Pipe Size (O.D.) DN08 DN10 DN15 DN20 DN25 DN40 DN50 DN65 DN80 DN100 (¼") (") (½") (¾") (1") (1½") (2") (2½") (3") (4") LPM | GPM 0.3m/s min. 0.6 | 0.16 1.8 | 0.48 3.5 | 1.0 5.0 | 1.5 9.0 | 2.5 25.0 | 6.5 40.0 | 10.5 60.0 | 16.0 90.0 | 24.0 125.0 | 33.0 LPM | GPM 10m/s max. 12 | 3 50 | 13 120 | 32 170 | 45 300 | 79 850 | 225 1350 | 357 1850 | 357 2800 | 739 4350 | 1149 SS Only SS Only = PVC Bar Psi 15.2 220 13.8 200 12.4 180 11.0 160 9.7 140 8.3 120 6.9 100 5.5 80 4.1 60 2.8 40 1.4 20 00 ºF 68 104 ºC 20 40 = PP 140 175 60 80 = PVDF 212 248 100 120 2F4i-n05d65Qu©aIclointyProPcreossdCuonctrtosls OLtdn. line at: Valuetesters.com info@valuetesters.com5 Truflo® -- TKW | TK3W Series (Blind) In-Line Paddle Wheel Flow Meter Sensor Exploded View 1 6 5 4 2 3 1 Flow Controller 2 Rotor Assembly 3 Body - PVC | PP | PVDF 4 Rotor Pin 5 Rotor Bushing 6 ShearPro® Paddle Wheel 7 7 Reinforced Inserts 2" Dimensions 1/2" Same Controller | Rotor Assembly for All Sizes 50 40 4 2 2 9 2F4i-n05d65Qu©aIclointyProPcreossdCuonctrtosls OLtdn. line at: Valuetesters.com info@valuetesters.com6 Truflo® -- TKW | TK3W Series (Blind) In-Line Paddle Wheel Flow Meter Sensor K-Factors for TK Series (V1) Size ¼" " ½" ¾" 1" 1½" 2" 3" 4" LPM 547 300 124 72 54 19 10.3 4.7 2.1 GPM 2079 1140 471 274 171 72 39 18 8 K-Factor is Pre-Programmed K-Factors for TK Series (V2) Size ½" ¾" 1" 1½" 2" 2½" K-Factor 127.6 81.8 55.1 18.8 10.2 6.0 Range of Transmitter Size DN8* | 1/4" DN10* | 3/8" DN15 | ½" DN20 | ¾" DN25 | 1" Range LPM | GPM 06 LPM | 01.6 GPM 015 LPM | 04 GPM 030 LPM | 08 GPM 060 LPM | 016 GPM 090 LPM | 024 GPM Model Selection Size DN40 | 1 ½" DN50 | 2" DN80 | 3" DN100 | 4" Range LPM | GPM 0200 LPM | 053 GPM 0330 LPM | 087 GPM 0750 LPM | 0198 GPM 01300 LPM | 0344 GPM * SS Only Size ½" ¾" 1" 1 ½" 2" 3" 4" PVC End Connections Sch 80 Soc Sch 80 Soc Sch 80 Soc Sch 80 Soc Sch 80 Soc Flanged Flanged Part Number TKW-15-P TKW-20-P TKW-25-P TKW-40-P TKW-50-P TKW-80-P TKW-100-P Add 1st Suffix (end connection): -T NPT End Connectors (on PVC) -B Butt Fused End Connections for PP or PVDF -F Flange ANSI 150lb - Consult Factory Size ½" ¾" 1" 1 ½" 2" 3" 4" PP End Connections NPT NPT NPT NPT NPT Flanged Flanged Add 2nd Suffix (seals): FKM (std, no suffix required) -E EPDM Seals -K FFKM | Kalrez® Seals Part Number TKW-15-PP TKW-20-PP TKW-25-PP TKW-40-PP TKW-50-PP TKW-80-PP TKW-100-PP Size ½" ¾" 1" 1 ½" 2" PVDF End Connections NPT NPT NPT NPT NPT Part Number TKW-15-PF TKW-20-PF TKW-25-PF TKW-40-PF TKW-50-PF Add 3rd Suffix (optional output): -A 4-20mA Output -V 0-5 V Output -PA 4-20mA + Pulse Output PVC Socket Ends (Std) Note: PP/PVDF NPT Ends (Std) Size ¼" " ½" ¾" 1" 1 ½" 2" 3" 4" 316 SS End Connections NPT NPT NPT NPT NPT NPT NPT NPT NPT Part Number TK3W-08-SS TK3W-10-SS TK3W-15-SS TK3W-20-SS TK3W-25-SS TK3W-40-SS TK3W-50-SS TK3W-80-SS TK3W-100-SS Add 1st Suffix (end connection): -T NPT End Connectors -SE Sanitary - Consult Factory for Pricing -F Flange ANSI 150lb - Consult Factory Add 3rd Suffix (optional output): -A 4-20mA Output -V 0-5 V Output -PA 4-20mA + Pulse Output Add 2nd Suffix (seals): FKM (std, no suffix required) -E EPDM Seals -K FFKM | Kalrez® Seals 316SS PC PVC PP PVDF 2F4i-n05d65Qu©aIclointyProPcreossdCuonctrtosls OLtdn. line at: Valuetesters.com info@valuetesters.com7 Truflo® -- TKW | TK3W Series (Blind) In-Line Paddle Wheel Flow Meter Sensor Installation Position 10x 3x CORRECT INCORRECT 10x CORRECT 3x CORRECT INCORRECT 10x 3x INCORRECT CORRECT 10x 3x INCORRECT Please Ensure Full Pipe TK Series can be installed in a horizontal or vertical direction. Please ensure enough length of straight pipe to avoid turbulence that can effect readings. Note: Min 10x Pipe Diameters Upstream 3x Pipe Diameters Downstream. A Plastic Basket Strainer, Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers - max 10% Particle Size - Not to Exceed .5mm Cross Section or Length. Please do not flush the pipe after the Flow Meter is installed with Compressed Air this may damage the ceramic shaft and will Void Warranty. 2F4i-n05d65Qu©aIclointyProPcreossdCuonctrtosls OLtdn. line at: Valuetesters.com info@valuetesters.com8 Truflo® -- TKW | TK3W Series (Blind) In-Line Paddle Wheel Flow Meter Sensor Warranty, Returns and Limitations Warranty Icon Process Controls Ltd warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service in accordance with instructions furnished by Icon Process Controls Ltd for a period of one year from the date of sale of such products. Icon Process Controls Ltd obligation under this warranty is solely and exclusively limited to the repair or replacement, at Icon Process Controls Ltd option, of the products or components, which Icon Process Controls Ltd examination determines to its satisfaction to be defective in material or workmanship within the warranty period. Icon Process Controls Ltd must be notified pursuant to the instructions below of any claim under this warranty within thirty (30) days of any claimed lack of conformity of the product. Any product repaired under this warranty will be warranted only for the remainder of the original warranty period. Any product provided as a replacement under this warranty will be warranted for the one year from the date of replacement. Returns Products cannot be returned to Icon Process Controls Ltd without prior authorization. To return a product that is thought to be defective submit a customer return (MRA) request form and follow the instructions therein. All warranty and non-warranty product returns to Icon Process Controls Ltd must be shipped prepaid and insured. Icon Process Controls Ltd will not be responsible for any products lost or damaged in shipment. Limitations This warranty does not apply to products which: 1. are beyond the warranty period or are products for which the original purchaser does not follow the warranty procedures outlined above; 2. have been subjected to electrical, mechanical or chemical damage due to improper, accidental or negligent use; 3. have been modified or altered; 4. anyone other than service personnel authorized by Icon Process Controls Ltd have attempted to repair; 5. have been involved in accidents or natural disasters; or 6. are damaged during return shipment to Icon Process Controls Ltd Icon Process Controls Ltd reserves the right to unilaterally waive this warranty and dispose of any product returned to Icon Process Controls Ltd where: 1. there is evidence of a potentially hazardous material present with the product; 2. or the product has remained unclaimed at Icon Process Controls Ltd for more than 30 days after Icon Process Controls Ltd has dutifully requested disposition. This warranty contains the sole express warranty made by Icon Process Controls Ltd in connection with its products. ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY DISCLAIMED. The remedies of repair or replacement as stated above are the exclusive remedies for the breach of this warranty. IN NO EVENT SHALL Icon Process Controls Ltd BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING PERSONAL OR REAL PROPERTY OR FOR INJURY TO ANY PERSON. THIS WARRANTY CONSTITUTES THE FINAL, COMPLETE AND EXCLUSIVE STATEMENT OF WARRANTY TERMS AND NO PERSON IS AUTHORIZED TO MAKE ANY OTHER WARRANTIES OR REPRESENTATIONS ON BEHALF OF Icon Process Controls Ltd. This warranty will be interpreted pursuant to the laws of the province of Ontario, Canada. If any portion of this warranty is held to be invalid or unenforceable for any reason, such finding will not invalidate any other provision of this warranty. by 2F4i-n05d65Qu©aIclointyProPcreossdCuonctrtosls OLtdn. line at: Valuetesters.com info@valuetesters.com9