Drummond 1/10 HP Non-Submersible Transfer Pump

Owner's Manual & Safety Instructions

Important Safety Information

Save this manual for future reference. It contains important safety warnings and precautions, assembly, operating, inspection, maintenance, and cleaning procedures. Record the product's serial number or purchase date in the manual.

CAUTION: This pump has been evaluated for use with water only.

WARNING: Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL.

Before start-up, note the following: The pump must be connected to a GFCI protected plug installed according to regulations, with a supply voltage of 120 VAC at 60 Hz.

IMPORTANT! For your own safety - before starting to run the pump, please have the following items checked by an expert:

  1. Risk of electric shock: Ensure connection to a properly grounded, grounding-type receptacle.
  2. This pump has not been investigated for use in swimming pool areas.
  3. Electrical connections must be protected from moisture.
  4. If there is danger of flooding, electrical connections must be taken to higher ground.
  5. Avoid circulation of caustic fluids and abrasive materials.
  6. Protect the pump from frost.
  7. Protect the pump from running dry.
  8. Prevent access by children with appropriate measures.
  9. WARNING: To prevent death from electric shock, pump must be connected only to a GFCI protected outlet.
  10. Do not pump flammable materials. Motor brushes may spark and cause explosions.
  11. Do not use an extension cord with this item.
  12. People with pacemakers should consult their physician(s) before use due to potential electromagnetic field interference.
  13. The warnings, precautions, and instructions in this manual cannot cover all possible conditions. Common sense and caution are essential.

Fluid Type

The pump is designed for use with water with a maximum temperature of 95° F (35°C). Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products.

Specifications

Specification Details
Horse Power 1/10 HP
Electrical Rating 120VAC / 60Hz / 1.8A
Power Cord Length 6'
Maximum Flow @ 0' 320 GPH
Maximum Head lift @ 0 Flow 42'
Discharge Port 3/4" Garden Hose Thread

Installation

The pump must be installed in a stationary position with either:

Please note!

  1. Do not allow the pump to hang suspended by the power cord, inlet pipe or hose. Set the pump on a stable surface or suspend from the handle. Keep the intake area free from sludge and dirt.
  2. If the water level sinks too low, sludge may dry out and stop the pump from starting. Check the pump regularly with start-up tests.

Power Supply

  1. The pump is equipped with a shock-proof plug. Connect to a 120 VAC, 60 Hz GFCI protected socket.
  2. Ensure the socket is sufficiently secured and in excellent condition.
  3. WARNING: To prevent death from electric shock, pump must be connected only to a GFCI protected outlet.
  4. WARNING! TO PREVENT SERIOUS INJURY: If the power cord or plug is damaged, do not use the pump. Have it repaired by a certified electrician.

Areas of use

  1. This pump is designed to pump water only.
  2. Used for general purpose removal or transfer of clear water.
  3. This pump should NOT be used for: Continuous run, fountain/pond water features, removing water from swimming pools or spas, septic or sewage systems.
  4. Can also be used to transfer water (e.g. household, farming, plumbing).

Installation Instructions

  1. Attach hose to Pump intake port. Attach second hose to Pump discharge port.
  2. Position Pump on solid surface so that both hoses are free from kinks.
  3. Place unused end of intake hose in water to be transferred. Place unused end of discharge hose as needed to direct water discharge at least 3 feet away from the source.

Operation

After reading these instructions, consider the following points before starting the pump:

  1. Verify that the discharge pipe is properly connected.
  2. Verify that the electrical connection is 120 VAC, 60 Hz.
  3. Verify that the electrical socket is GFCI protected and in good condition. Test GFCI protected outlet before use.
  4. Verify that water and moisture cannot get near the power supply socket.
  5. Verify that the pump is installed to prevent running dry.
  6. Once plugged in, the pump will continue pumping until it is unplugged.

NOTE: Using the included attachment, the Pump will remove water down to 1/8". Unplug the Pump once 1/4" water level is reached.

Figure A: GFCI Outlet [Diagram showing a GFCI protected receptacle]

Maintenance

WARNING: TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Unplug the Pump from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.

If the pump is moved during operation, flush it out with clean water after every use.

Quarterly Maintenance

Perform the below maintenance at least once every 3 months. For frequent use, or dirty areas, more frequent maintenance is required.

  1. Clean sludge and debris from the bottom of the basin.
  2. Clean sludge/debris from inlet screen.
  3. Make sure discharge pipe is free from leaks.
  4. Make sure check valve is functioning properly.

Parts List and Diagram

PLEASE READ THE FOLLOWING CAREFULLY

The manufacturer and/or distributor has provided the parts list and assembly diagram in this manual as a reference tool only. Neither the manufacturer or distributor makes any representation or warranty of any kind to the buyer that he or she is qualified to make any repairs to the product, or that he or she is qualified to replace any parts of the product. In fact, the manufacturer and/or distributor expressly states that all repairs and parts replacements should be undertaken by certified and licensed technicians, and not by the buyer. The buyer assumes all risk and liability arising out of his or her repairs to the original product or replacement parts thereto, or arising out of his or her installation of replacement parts thereto.

Parts List

Part Description Qty. Part Description Qty.
1 Machine Screw 4 9 Rubber Ring 1
2 Cover 1 10 Motor 1
3 Gasket 1 11 Brush 2
4 Machine Screw 2 12 Brush Cap 2
5 Handle 1 13 Foot 4
6 Impeller 1 14 Intake Attachment 1
7 Pump Body 1 15 Rubber Connector 1
8 Oil Seal 1 16 Inlet Hose 1

Record Product's Serial Number Here:

Note: If product has no serial number, record month and year of purchase instead.

Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. Reference UPC 193175314840.

Assembly Diagram [Diagram showing the assembly of the pump components with numbered parts]

Limited 90 Day Warranty

Harbor Freight Tools Co. warrants this product to be free from defects in materials and workmanship for 90 days from the date of purchase for the original purchaser. This warranty does not apply to damage due to misuse, abuse, negligence, accidents, unauthorized repairs or alterations, improper installation, normal wear and tear, or lack of maintenance. Harbor Freight Tools shall not be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.

This warranty is expressly in lieu of all other warranties, express or implied, including the warranties of MERCHANTABILITY AND FITNESS.

To take advantage of this warranty, return the product or part with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If the defect is verified, Harbor Freight Tools will repair or replace the product, or refund the purchase price. Repaired products will be returned at Harbor Freight's expense. If no defect is found, or if the defect resulted from causes not within the scope of the warranty, the cost of returning the product must be borne by the customer.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Models: 63317, 1 10 Non-Submersible Transfer Pump

File Info : application/pdf, 8 Pages, 601.30KB

PDF preview unavailable. Download the PDF instead.

63317-193175314840 macOS Version 10.15.7 (Build 19H15) Quartz PDFContext

Related Documents

Preview Drummond 1/10 HP Non-Submersible Transfer Pump Owner's Manual & Safety Instructions
Comprehensive owner's manual and safety instructions for the Drummond 1/10 HP Non-Submersible Transfer Pump (Model 63317). Covers specifications, installation, operation, maintenance, troubleshooting, parts list, and warranty information.
Preview Drummond 1/2 HP Submersible Sump Pump Owner's Manual & Safety Instructions
Comprehensive guide for the Drummond 1/2 HP Submersible Sump Pump (Item 58012), covering safety warnings, operating instructions, installation, maintenance, parts list, and warranty information.
Preview Drummond Submersible Utility Pump Owner's Manual & Safety Instructions
Comprehensive owner's manual and safety instructions for the Drummond 1/3 HP and 1/6 HP Submersible Utility Pump. Includes assembly, operation, maintenance, troubleshooting, parts list, and warranty information.
Preview Drummond 1/2 HP Submersible Sewage Pump Owner's Manual & Safety Instructions
Comprehensive guide for the Drummond 1/2 HP Submersible Sewage Pump, covering safety precautions, installation, operation, maintenance, troubleshooting, parts list, and warranty information.
Preview Drummond 1/3 HP Submersible Sump Pump Owner's Manual & Safety Instructions
Comprehensive owner's manual and safety instructions for the Drummond 1/3 HP Submersible Sump Pump (Item 57718). Covers setup, operation, maintenance, troubleshooting, and warranty information.
Preview Drummond 1 HP Stainless Steel Shallow Well Pump and Tank Owner's Manual
Owner's manual and safety instructions for the Drummond 1 HP Stainless Steel Shallow Well Pump and Tank. Includes assembly, operating, inspection, maintenance, and troubleshooting information.