Instructions for ARROW models including: CDA-45703-P1A Pressure Injectable Arrowg ard Blue Plus Three-Lumen CVC, CDA-45703-P1A, Pressure Injectable Arrowg ard Blue Plus Three-Lumen CVC
CDA-45703-P1A - Teleflex Incorporated - Vascular Access Product Catalog
10 5 5 CDA-45703-P1A 7 3 Fr. Lumen 20cm catheter length .032 inch dia. spring-wire guide Pressure Injectable Arrowg+ard Blue Plus® Three-Lumen CVC Contents: 1: Arrowg+ard Blue Plus®1 Three-Lumen Catheter: 7 Fr. (2.5 mm OD) x 20 cm, Pressure Injectable 1: Spring-Wire Guide, Marked: .032" (0.81 mm) dia. x 23-5/8" (60 cm) (Straight Soft Tip on One End - "J" Tip on Other) with Arrow Advancer 1: Catheter: 18 Ga. x 2-1/2" (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle 1: Pressure Transduction Probe 1: Introducer Needle: Echogenic 18 Ga. x 2-1/2" (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe 1: Injection Needle: EclipseTM2 22 Ga. x 1-1/2" (3.81 cm) RW and 5 mL Luer-Slip Syringe 1: Injection Needle: EclipseTM2 25 Ga. x 1" (2.54 cm) RW and 3 mL Luer-Lock Syringe 1: Syringe: 10 mL Luer-Lock 1: Tissue Dilator: 8.5 Fr. (2.8 mm) x 10.2 cm 1: SecondSiteTM Adjustable Hub: Fastener 1: SecondSiteTM Adjustable Hub: Catheter Clamp 1: SharpsAway® Disposal Cup 1: SharpsAway® II Locking Disposal Cup 1: Maximal Barrier DrapeTM with 4" fenestration 1: Towel 1: Needle Holder 1: Forceps 1: Safety Scalpel: #11 1: Checklist/CLIP Sheet 1: Sterile Procedure Sign 2: Gauze Pad: 2" x 2" (5 cm x 5 cm) 5: Gauze Pad: 4" x 4" (10 cm x 10 cm) 1: Dressing: Tegaderm®3 10 cm x 12 cm 1: Surgical Apparel: Impervious Gown 1: Surgical Apparel: Bouffant Cap 1: Surgical Apparel: Mask with Eye Shield 1: Suture: 3-0 Silk with Curved Needle 1: HemoHopper® Fluid Receptacle 1Licensed under US Patent No. 7,329,412. 2A trademark of Becton, Dickinson and Company. 3A registered trademark of 3M Company. Not made with natural rubber latex. Store below 25°C (77°F). Avoid excessive heat above 40°C (104°F). Contraindications: The Arrowg+ard Blue Plus antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs. Lumen Priming Volume* (mL) Distal (16 Ga.) 0.39 Medial (18 Ga.) 0.39 Proximal (18 Ga.) 0.40 Gravity Flow Rate (mL/hr) 2283 913 996 MAX Pressure Injection Flow Rate** (mL/sec) 10 5 5 * Priming volumes are approximate and are done without accessories. Flow rate values are approximate and are determined using deionized water at 100 cm head height. ** Pressure injection flow rates are determined using media of 11.8 centipoise (cP) viscosity, with 152 cm administration set tubing. LBL053595 R00 (2022-01)iText 2.1.7 by 1T3XT