Everbilt SBA025HPACK Pre-Plumbed Laundry/Sink Tray System

Use and Care Guide

SKU: 1000 143 218 | Model: SBA025HPACK

Safety Information

PRECAUTIONS

  1. Keep this instruction manual in a safe place for future reference.
  2. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset itself once the motor cools down and an acceptable temperature has been reached. The pump may start unexpectedly if it is plugged in.
  3. Ensure the electrical power source is adequate for the requirements of the pump.
  4. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump problems and remedies.

[DANGER] Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting in property damage, serious personal injury, and/or death.

[DANGER] ALWAYS disconnect the power to the pump before servicing.

[DANGER] Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not disassemble the motor housing.

[DANGER] Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water. If basement floor is wet, do not walk on wet area until all power is turned off. If shut-off box is in basement, call the electric company to shut off service to the house, or call your local fire department for instructions. Remove pump and repair or replace. Failure to follow this warning can result in fatal electrical shock.

[WARNING] Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension cord to power this pump is not permitted.

[WARNING] Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury, and/or property damage.

[WARNING] Release all pressure and drain all water from the system before servicing any component.

[WARNING] Wear safety goggles at all times when working with pumps.

[WARNING] This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should be performed by a qualified electrician.

[WARNING] Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use damaged or worn cords.

[WARNING] Always electrically ground pump motor to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway system, or to a ground wire system.

[WARNING] Failure to comply with the instruction and designed operation of this unit may void the warranty. Attempting to use a damaged pump can result in property damage, serious personal injury, and/or death.

[WARNING] Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker.

[CAUTION] Do not lift the pump by the power cord.

[CAUTION] Know the pump and its applications, limitations, and potential hazards.

[CAUTION] Place the pump on a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure.

[CAUTION] Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and debris. Disconnect the pump from the power supply before inspecting.

[CAUTION] Follow all safety standards and all local electrical codes.

Warranty

The manufacturer warrants to the original consumer purchaser of the sink tray system that they will be free from defects in material and workmanship for the Warranty Period of 12 months from date of purchase. The date of purchase shall be determined by the original dated sales receipt noting the model number of the system. The original sales receipt must accompany the returned system. If the system fails during the warranty period, disconnect the power, disconnect all plumbing and piping, empty any water from the basin and return the entire system to The Home Depot along with the receipt.

The manufacturer shall not be liable under this Warranty for any product that, in the manufacturer's sole judgment, has been subject to negligence, misapplication, improper installation, or improper maintenance. Also, the manufacturer shall not be liable under this Warranty if the product has been disassembled, modified, abused or tampered with; if the electrical cord has been cut, damaged or spliced; if the pump discharge has been reduced in size; if the pump has been used in water temperatures above the advertised rating, or water containing sand, lime, cement, gravel or other abrasives; if the product has been used to pump chemicals or hydrocarbons; or if the label bearing the system model has been removed.

Your sole remedy, and the manufacturer's only duty, is that the manufacturer repair or replace defective systems (at the manufacturer's choice). You must pay all labor and shipping charges associated with this warranty. No request for service will be accepted if received after the Warranty Period has expired. This warranty is non-transferable.

The manufacturer shall not be liable for any consequential, incidental, or contingent damages whatsoever. The manufacturer recommends using a professional plumber for all installation and repair, and periodic inspection of the manufacturer's pumps, plumbing connections, and electrical cord. The manufacturer makes no warranty regarding the suitability of a product for a particular installation.

This warranty excludes all industrial, agricultural, commercial and business usage of this system.

The foregoing warranties are exclusive and in lieu of all other express and implied warranties, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. The foregoing warranties shall not extend beyond the duration expressly provided herein.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of the implied warranty, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. This warranty applies to only pumps installed in the United States of America and Canada.

This warranty supersedes and replaces all previous warranty publications.

Contact the Customer Service Team at 1-844-241-5521 or visit WWW.HOMEDEPOT.CA. For warranty registration please go to www.gppumpsus.com.

Pre-Installation

APPLICATION

This sink tray system is designed for home application. Use this system only for pumping water. This system has not been tested or approved for use in swimming pools or in salt-water marine areas. It is also not engineered to be run continuously as a "fountain" or "waterfall" pump.

INSTALLATION OPTIONS

[WARNING] To prevent lint from the washing machine's discharge from clogging the pump and causing a flood, cover the end of the discharge hose from the washing machine. Regularly check nylon stocking or filter for accumulation of lint that may prohibit proper water flow from the washing machine.

Installation for Laundry Sinks and Washing Machines - Typical

This setup shows the sink tray system connected to a laundry sink and a washing machine. Water from both sources flows into the sink tray, which then pumps it out via the discharge line. A vent pipe is also shown.

Installation for Wet Bar - Typical

This setup illustrates the sink tray system installed for a wet bar. Water from the wet bar sink drains into the sink tray, which then pumps it away through the discharge line. A vent pipe is included.

Installation to Remove Air Conditioner Condensate or Humidifier Water - Typical

This configuration shows the sink tray system used to pump condensate water from an air conditioner or humidifier. The water collects in the sink tray and is discharged through the pump's system, which includes a vent pipe.

TOOLS REQUIRED

  • Flathead screwdriver
  • Phillips screwdriver
  • Hand hacksaw or PVC cutter
  • Wrench
  • Tape measure
  • PVC Primer
  • PVC Cement
  • Safety goggles
  • Thread tape

MATERIALS REQUIRED (NOT INCLUDED)

Before using this pump, ensure you have the following items:

  • 1-1/2 in. PVC Schedule 40 Pipe
  • 1-1/2 in. PVC Schedule 40 Elbow
  • 1-1/2 in. PVC Schedule 40 Threaded Male Adaptor (x3)
  • Nylon stocking (washing machine application only)

PRODUCT DESCRIPTION

The system comprises the following main components:

Part Description
A Basin lid with bolts
B Cord grommet
C Lid gasket
D Sump pump check valve and discharge pipe assembly
E Basin with bolt inserts
F Pump lock plate (sits on bottom of basin locking pump in place)
G 1/4 HP Sump Pump with Vertical Switch

The diagram shows an exploded view of the basin (E) with the lid (A), cord grommet (B), lid gasket (C), check valve assembly (D), pump lock plate (F), and the sump pump (G) inside the basin.

Installation

1. Attaching the inlet connection

  • Install a 1-1/2 in. PVC Schedule 40 threaded male adaptor (labeled '1' in diagrams) (not included) into the basin's inlet hole (labeled '2' in diagrams). Use Teflon tape, silicon sealant, or plumber's pipe dope to seal the threads.
  • Connect the inlet piping (labeled '3' in diagrams) (not included) to the 1-1/2 in. PVC Schedule 40 threaded male adaptor (1) using PVC primer and solvent cement to properly seal the connection.

Diagram shows basin components: male adaptor (1) inserted into inlet hole (2), with inlet piping (3) to be connected.

2. Attaching the discharge pipe connection

  • Install a 1-1/2 in. PVC Schedule 40 threaded male adaptor (1) (not included) into the discharge hole as shown. Ensure it is the discharge port, not the vent port. Use Teflon tape, silicon sealant, or plumber's pipe dope to seal the threads.
  • Connect 1-1/2 in. PVC schedule 40 pipe (2) (not included) and elbow (3) (not included) to the male adaptor (1). Use PVC primer and solvent cement to properly seal the connection.
  • Connect discharge piping to the 1-1/2 in. PVC Schedule 40 elbow (3) using PVC primer and solvent cement to properly seal the connection. Continue discharge piping to the sewer pipe or final out-fall. It is suggested that a union be installed on this line to allow for easy pump service or removal.

Diagram shows basin components: male adaptor (1) inserted into discharge hole, connected to pipe (2) and elbow (3), with the 1/4 HP Sump Pump (G) inside the basin.

3. Attaching the vent connection

  • Install a 1-1/2 in. PVC Schedule 40 threaded male adaptor (1) (not included) into the vent hole as shown. Use Teflon tape, silicon sealant, or plumber's pipe dope to seal the threads.
  • Connect a vent pipe (2) (not included) to the 1-1/2 in. PVC Schedule 40 threaded male adaptor (1) using PVC primer and solvent cement to properly seal the connection. Connect the vent pipe to the sewer's vent system. It is suggested that a union be installed on this line to allow for easy pump service or removal.

Diagram shows basin components: male adaptor (1) inserted into vent hole, with vent pipe (2) to be connected.

4. Connecting the power and verifying proper operation

  • Make sure that the cord grommet is properly inserted into the lid. This assures a water and gas tight seal.
  • Plug the power plug into a 115V GFCI power outlet.
  • Check the pump by filling the sink tray basin with water and observe the pump's operation through one complete cycle.

Contact Information

For questions, problems, or missing parts, please contact Everbilt Customer Service before returning to the store.

Hours: 8 a.m. - 6 p.m., EST, Monday-Friday

Phone: 1-844-241-5521

Website: WWW.HOMEDEPOT.CA

For warranty registration, please go to www.gppumpsus.com.

For Professional Technical Support, call 1-844-241-5521.

PDF preview unavailable. Download the PDF instead.

SBA025HPACK Use and Care Guide(EN)-pdf Adobe Acrobat Pro 9.3.1

Related Documents

Preview Everbilt Submersible Sump Pump Use and Care Guide
Comprehensive guide for Everbilt submersible sump pumps, covering installation, operation, maintenance, and troubleshooting. Includes safety information and warranty details for models PSSP07501VD, PSSP10001VD, SP03302VD, and SP05002VD.
Preview Everbilt CSP010 Condensate Pump: Use, Care, and Troubleshooting Guide
Comprehensive guide for the Everbilt CSP010 condensate pump, covering installation, operation, safety precautions, performance specifications, and troubleshooting tips. Learn how to maintain your condensate pump for optimal performance.
Preview Everbilt Submersible Sump Pump Use and Care Guide
This guide provides essential information for the safe and effective use and care of Everbilt submersible sump pumps. It covers performance specifications, safety precautions, installation steps, operation, maintenance, and troubleshooting for models including SP03302VD, SP05002VD, PSSP07501VD, and PSSP10001VD.
Preview Everbilt Submersible Sump Pump Use and Care Guide (Model ECD50V-HDC)
This guide provides essential information for the safe installation, operation, maintenance, and troubleshooting of the Everbilt Submersible Sump Pump, Model ECD50V-HDC. Learn about safety precautions, performance specifications, and common issues to ensure optimal pump performance.
Preview Everbilt Submersible Sump Pump Use and Care Guide | SBA025BC, SBA033BC, SBA033V1, SBA050BC
Comprehensive use and care guide for Everbilt submersible sump pumps, including installation, operation, safety information, maintenance, and troubleshooting for models SBA025BC, SBA033BC, SBA033V1, and SBA050BC. Find contact information and specifications.
Preview Everbilt Sump Pump Use and Care Guide: HDS30, HDS50, HDS75
This guide provides essential information for the safe installation, operation, maintenance, and troubleshooting of Everbilt Sump Pumps, models HDS30, HDS50, and HDS75. Learn about safety precautions, performance charts, required materials, and warranty details.
Preview Everbilt Submersible Sump Pump Use and Care Guide | SP03302EP, SP05002VD
This comprehensive guide provides essential information for the safe and effective use, care, and maintenance of Everbilt submersible sump pumps, models SP03302EP and SP05002VD. Learn about performance specifications, assembly, operation, troubleshooting, and warranty details.
Preview Everbilt THD1095 Pre-Plumbed Sump Basin System: Use and Care Guide
This guide provides essential information for the installation, use, and care of the Everbilt THD1095 pre-plumbed sump basin system, featuring a 3/10 HP sump pump. Learn about safety precautions, product features, and warranty details.