User Guide for Felicity Solar models including: LPBF48200-H, 358-010286-04, LiFePO4 Battery System For Households, LiFePO4, Battery System For Households, Households

358-010286-04

[PDF] USER GUIDE cn.felicitysolar.com › u file › file › LPBF48200-HManual2024-9-13

USER GUIDE - ueeshop.ly200-cdn.com

06 LiFePO4 Battery System for Households 05 LiFePO4 Battery System for Households Please follow below steps to implement battery connection: Assemble battery ring terminal based on recommended battery cable and terminal size.


File Info : application/pdf, 7 Pages, 3.10MB

PDF preview unavailable. Download the PDF instead.

LPBF48200-HManual2024-9-13
LiFePO4 Battery System for Households

Make life full of hope
USER GUIDE
LiFePO4 Battery System for Households

358-010286-04

Contents

6

6

7

7 8 9

10

10

10

10

5.4 Damaged Batteries ............................................................................... 10

5.5

10

LiFePO4 Battery System for Households
1 ABOUT THIS MANUAL
1.1 Purpose
This manual describes the introduction, installation, operation and emergency situations of the battery bank. Please read this manual carefully before installations and operations. Keep this manual for future reference.
1.2 Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
1.3 Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
1.Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
2. CAUTION ­-- To reduce risk of injury,damage,even burst. please use it following using manual. In case of causing personal
3. Do not disassemble the battery. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of fire.
4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
5. CAUTION ­ Only qualified personnel can install this device with inverter. 6. For optimum operation of this battery, please follow required spec to select appropriate cable size. 7. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool
to spark or short circuit batteries or other electrical parts and could cause an explosion or fire. 8. Please strictly follow installation procedure. 9. GROUNDING INSTRUCTIONS - This System should be connected to a permanent grounded wiring
system. Be sure to comply with local requirements. 10. NEVER cause AC output and DC input short circuited. Do not connect to the mains when DC input
short circuits. 11. Warning!! Only qualified service persons are able to service this device. 12. Battery should be installed indoor and kept away from water, high temperature mechanical force and flames. 13. Do not install the battery in any environment of temperature below 0°C or over 55°C,and humidity over 80%. 14. Do not put any heavy objects on the battery.
1.4 Can be connected in parallel
1. The batteries can be connected in parallel. Series connection is not allowed. Use in upright position only.
2. The batteries are not allowed to connected with PWM controller for charging.
Special Attention: Due to the built-in protection board of the lithium battery pack is with over-discharge protection function, it is strongly recommended to stop using the load when the battery pack is over-discharged. The battery pack cannot be repeatedly activated for discharge. Or the battery may be failed to be activated by the AC or PV activation cable ( It requires a special charging activation method), so cannot be charged. Therefore, when the battery pack is low power, please charge the battery as soon as possible when main power or solar energy is available.
01

LiFePO4 Battery System for Households
2. INTRODUCTION
The battery system main using Solar power system for Family house. It also have a with to controller the battery easily and protect our Household application timely.
2.1 Features
· LiFePO4: Higher safe performance and longer cycle life. · Multiple Protection: Built-in smart BMS and Fuse. · Flexible Installation: Wall-Mounted or Floor-Mounted. · Wide Compatibility: Compatible with leading inverter brands. · High Scalability: Capacity up to 30kWh. · Long Warranty: 5 Years.
2.2 Product OverView

48V Front view

8

8

7

4

1

5

3

8

6

2

1. LCD display 4. Switch 7. Wall mounted fixing

2. Battery Negative 5. Communication port 8. Power On/Charging indicator

3. Battery Positive + 6. Earth wire

02

LiFePO4 Battery System for Households

2.3 Specifications

Model

LPBF48100-H

LPBF48200-H

Capacity

5kWh

10kWh

Battery Type

LiFePO4

LiFePO4

Nominal Voltage

51.2V

51.2V

Operating Voltage

48-57.6V

48-57.6V

Recommend Charge/Discharge Current[1]

50A

80A

Recommend Charge/Discharge Power[1]

2,500W

4,000W

Maximum Charge/Discharge Current(15s)

100A

120A

Maximum Charge/Discharge Power(15s)

5,000W

6,000W

Depth of Discharge(DOD) Scalability Communication Protection Level Cycle Life[2] Charging Temperature Range Discharging Temperature Range Display Installation Protection Warranty Net Weight

95%

Up to 6 units in parallel(60kWh)

RS485 / CAN

IP21

 6000 Cycles

0-55°C

-20-60 °C

LCD+LED

Wall-Mounted / Floor-Mounted

Built-in smart BMS, Fuse

63kg

5 Years

76kg

Gross Weight

76kg

89kg

Product Dimension

575x430x258mm

685x475x213mm

Package Dimension

670x525x415mm

[1] Recommend charge/discharge current/power is affected by temperature and SOC.

780x570x375mm

[2] Test conditions: 0.2C Charging/Discharging @25°C, 80% DOD.

2.4 Recommended Settings
Lithium battery pack is not same as lead-acid battery, so for the devices which you connect with the battery pack for charging or discharging, such as inverters, MPPT charger controllers or UPS, please implement pre-settings as recommended settings as below before you launched them.

Setting

LPBF48100-H

Max. Charging Voltage

57.6V

Floating charging Voltage

57.6V

Max. Charging Current

50A*N

Cut-off voltage

48V

Notes: "N" means the number of battery packs connected in parallel.

LPBF48200-H 57.6V 57.6V 80A*N 48V

03

LiFePO4 Battery System for Households

RS485 cable
Communication cable

Battery terminal: 5B6A PCS terminal: 5B6A
Used for Communication among batteries

4

5

6

7

8

9

Universal

Flexibly match the communication cable

communication cable of different inverters

10 Ethernet connector Ethernet connector

NOTE:  in LPBF48100-H  in LPBF48200-H

4
9 10

LPBF48100-H 95 240 150 301 278 301 124 145 140

LPBF48200-H 117.5 240 208 301 388 301 180 167.5 140
04

LiFePO4 Battery System for Households
Please follow below steps to implement battery connection: Assemble battery ring terminal based on recommended battery cable and terminal size. Note: if you need the battery wake-up when the grid back, connect the battery with grid use power adapter and communication line 1 shown in the package list.
3.3 Connection for Parallel Mode
The eStrong LPBF series battery support to be connected in parallel for expansion. If you need one more battery bank work in parallel mode, connect the battery as shown in PIC 2
BTCB0606/BTCB0303

4. OPERATION

LiFePO4 Battery System for Households

Step 1: The schematic diagram of the parallel connection of three battery packs is shown in Figure 1.
Note:After completing the above steps, arbitrarily select the positive and negative poles of one of the battery packs to output. After confirming the correct connection of the inverter, controller and battery, you can turn on any of the switches and use the battery group happily.
For pure off grid system ,the PV awake wire need to be connected with MPPT charge controller if the battery pack is charged by solar panels only . The connection diagram as below :

4.1 Switch On / Off
1.Switch on: press On/Off button to switch on the battery, then the battery will do self-inspection before enable output. The LCD will show the SOC.
2.Switch off: press and hold On/Off button for 1to3 seconds, the battery will shut down directly. Description for Communication port

Picture

PIN

Description

1

Trigger-GND

2

Trigger-VCC

3

CANL-PCS

4

CANH-PCS

5

RS485-B

6

RS485-A

7

CANL

8

CANH

DIP SWITCH

1-4

Communication Address

5

Termination Resister

05

06

Eg: Rated voltage is "51.2V"; model is "5KWH", "01"is the countdown.

Eg: "52.0V" / "3.90KW" / "70%" refers to battery voltage. power and SOC.

Eg: "52.0V" / "50A" / "70%" refers to battery voltage. current and SOC.

Eg:"52.0V" / "C09"/"70%"arebatteryvoltage,fault codeandSOCrespectively,andFaulticonconstant.

Eg:"515"is the software version ;"400"is the IAP version and temporary version;"02"is the countdown.
A

overtemperature

5. EMERGENCY SITUATIONS
Felicity cannot guarantee battery absolute safety.
5.1 Fire
In case of fires, make sure that the following equipment is available near the system. · SCBA (self-contained breathing apparatus) and protective gear in compliance with the Directive on Personal
Protective Equipment 89/686/EEC. · NOVEC 1230, FM-200, or dioxide extinguisher Batteries may explode when heated above 150°C. KEEP FAR AWAY from the battery if it catches fire.
5.2 Leaking Batteries
If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. If one is exposed the leaked substance, immediately perform the cations described below. · Inhalation: Evacuate the contaminated area, and seek medical attention. · Contact with eyes: Rinse eyes with running water for 5 minutes, and seek medical attention. · Contact with skin: Wash the affected area thoroughly with soap and water, and seek medical attention. · Ingestion: Induce vomiting, and seek medical attention.
5.3 Wet Batteries
If the battery pack is wet or submerged in water, do not let people access it, and contact your supplier for help.
5.4 Damaged Batteries
Damaged batteries are not fit for use and are dangerous and must be handled with the utmost care. It may leak electrolyte or produce flammable gas. If the battery pack seems to be damaged, pack it in its original container, and then return it to your supplier.
5.5 Warranty
Products that are operated strictly in accordance with the user manual are covered by the warranty. Any violation of this manual may void the warranty. Limitation of Liability Any product damage or property loss caused by the following conditions, Felicity does not assume any direct or indirect liability. · Product modified, design changed or parts replaced. · Changed, or attempted repairs and erasing of series number or seals; · System design and installation are not in compliance with standards and regulations; · The product has been improperly stored in end user's premises; · Transport damage (including painting scratch caused by movement inside packaging during shipping). A claim should be made directly to shipping or insurance company.

