User Manual for CAS models including: CAS PR-II Price Computing Scale, CAS PR-II, Price Computing Scale, Computing Scale, Scale

User Manual

CAS PR-II Price Computing Scale - CAS Scales Australia

PDF preview unavailable. Download the PDF instead.

CAS-PR-II-User-Manual
1

PRECAUTIONS

3

PREFACE, OVERALL VIEW 5

DISPLAY & KEY BOARD

6

COLUMN INSTALLATION

8

OPERATION

9

Chapter 1. Basic Operation

9

Chapter 2. PLU Saving & Calling-up 12

Chapter 3. User' s Set-up Mode

13

Chapter 4. Sales transaction

13

Chapter 5. Payment

16

Chapter 6. Interface in Detail

18

BATTERY MAINTENANCE 21

ERROR MESSAGE

21

SPECIFICATIONS

22

2

3

4

Thank you for purchasing CAS PR series. These series have been designed with CAS reliability, under rigid quality control and with outstanding performance. Your special departments can enjoy these high quality reliable CAS products. We believe that your needs will be satisfied and you will have proper reliability. This manual will help you with proper operation and care of the PR. Please keep it handy for future reference.
5

PR II - B Front display PR II - B Rear display PR II - P Front cover & key
6

KEY FUNCTIONS

KEYS

FUNCTIONS

~

Used to enter all the numeric data

~

PLU key.

Function key(Back-light, Power Save Used to enter PLU setting
Used to clear all the numeric price display Used to clear sum total price Used to clear all the daily total prices

Used to correct the zero point

To set or clear tare value
PLU save key. To make several sales transaction by adding up.
To check total sales amount or finalize sales transaction.

Used to enter the decimal point when price is entered.

+

Used to change back-light setting.(OFF, ON, AUTO)

+

Power Save Mode

+

Used to price per 100g ($/100g)

7

8

 Turn on the ON/OFF switch. Then, the display will show all the segments and count up "9" to "0".
Chapter 1. Basic Operation
a. Zero function
 Press ZERO key to set Zero.
b. Tare function Tare means the weight of container. You may use tare function when you weigh an item with container and measure only the weight of item.
 One time tare
 Place a container on the platter. EX) 200g of tare.
 Press TARE key to set zero point. EX) 200g of tare.
9

 Successive tare

 Place another container on the platter. EX) 100g of tare.
 Press TARE key to set zero point.

 After weighing item remove all of the container from the platter.

 Press TARE key again to set zero.
 NOTICE To remove TARE funtion press "TARE" Key again after removing the container from the paltter. Automatic tare clearing function may not be applied to all of PR series.

10

Chapter 2. PLU Saving & Calling-up

a. Saving unit price on PLU This section explains how to save unit price in PLU.

PLU NAME

Number of PLU 7

Range 1~7

Remarks

 Press the 'Fn' key for a few seconds then, Set-up menu will be shown.

b. Calling up PLU

 After input unit of price, press number of PLU that you want to set up.
 Press M1 ~ M7 key to call up PLU. e,g, Press M1 key.

 Press C key to clear and return to the normal weighing mode.

11

Chapter 3. User's Set-up Mode

This section explains how to set up the following functions.

KEY

Display
bL-At

FUCTION
Use back-light when you put on the weight

+

bL-oFF

Do not use a back-light.

bL-on

Use back-light always

ps - 0
+ ps - 1

Do not use power save mode. Use power save mode

up- kg

Used to price per kg

+

up-100g

Used to price per 100g ($/100g).

rS-Co

Continually mode

+

rS-PC

rS-St

Command mode Stable mode

Remarks

12

Chapter 4. Sales transaction
PR- can provide inputting the unit price through the numeric key and calling up PLU. a. Input the unit price through the numeric key This section explains how to input the unit price through the numeric key and complete the sales transaction.
 Place an item on the platter and press appropriate numeric keys to input unit price. EX) 1.99 for unit price.
 Remove the item from the platter.
b. Input the unit price through calling up PLU
 Press M1~M7 key can call up the PLU. EX) M1
 Place an item on the platter.
 Remove an item on the platter.
c. Adding up several sales transactions for weighed items 13

 Use + key to makes the adding-up transactions.  You may either call up PLU or just input the unit price.
 Press M1~M7 key can call up the PLU. EX) M1
 Place an item on the platter.
 Press + key.
 Remove the item from the platter.  Input a unit price. EX) 2.99 for Honey melon  Place an item on the platter.
14

 Press + key. "Total Price" display says total price added, and "Unit Price" display says the number of sales transactions added.  Remove the item from the platter.
 You may also place the item on the platter first and then input unit price in the scale later.
15

Chapter 5. Payment
a. Payment function on total sales amount
 Press  key to call up total price. (If you want to go back to sales mode, press zero key.)  Input payment of consumer by numeric key. Ex) 120.00 payment  Press  key to call up the change amount.
 After checking the change amount press  key to go back to normal weighing mode.
16

b. Deleting total sales data

 Press  key to call up total price. (If you want to go back to sales mode, press zero key.)
 Press C key to delete "total sales" data. Clear account message shows up shortly, and then it goes to normal weighing mode.
 And then it goes to normal weighing mode.

17

Chapter 6. Interface in Detail
This function is helpful to understand RS-232C Communication user setting. The following is the communication information of RS-232C.  RS-232C Port Connection
 8-BIT ASCII code  None parity  1 stop bit  baud rate 9600  USB INTERFACE(Device)
18

 RS-232C Protocol

Transmission Data description

DATA
SOH STX STA SIGN W5~W0 UN1,UN2 BCC ETX EOT

Value(HEX)
01h 02h S(53h),U(55h) -(2Dh),SP(20h)
KG,LB
03h 04h

Description
Start of heading Start of text
S: Stable , U:Unstable Sign of the weight data
Weight data Unit of Weight Block check character exclusive or(^)
End of text End of transmission

19

COMMAND : DC2(0X12) SCALE -> PC DATA FORMAT
All Data Format (total price,weight,unit price)
20

LOW BATTERY WARNING
This product is a combination product dry battery and rechargeable battery. When the battery is low the display shows the " bAt-Lo " sign. You can replace the battery new one.
If rechargeable battery, please charge immediately. You can shorten battery life.
If you still use the scale without replacing the battery the scale may provide incorrect result on measurement.

Error Message on Display

Description

The "Z-Err" occurs when a current zero point has shifted from the last span calibration.

The "oL" is an overload error.

The "bAt-Lo" is battery low.

Solution
Please call your CAS dealer.
Please remove the weight.
Please change new battery. If rechargeable battery, please charge immediately.

21

MODEL : PR

Capacity

Dual Interval
Max 3/6kg

Single
Max 6kg

Dual Interval
Max 6/15kg

Single
Max 15kg

Dual Interval
Max 15/30kg

Single
Max 30kg

e=2g

e=5g

e=10g

e

e=1/2g

e=1g e=0.5g

e=2/5g

e=2g e=1g

e=0.5/1g

e=5g e=2g

e=0.2g

e=0.5g

e=1g

External Resolution

1/3000

1/3000~ 1/30000

1/3000

1/3000~ 1/30000

1/3000

1/3000~ 1/30000

MAX Tare -1.4995 kg -2.999 kg -5.998 kg -14.995 kg -14.995 kg -29.990 kg

Display

6/6/6(Weight / Unit price/ Total price)

Symbols ZERO, TARE, kg/lb,100g/1oz, ADD, SUM, Low Battery, AC POWER

Keys

ZERO, TARE, M1~M7 KEY, FUCTION, ADD, SUM

Functions
Dimension s Platter size

Direct PLU 7 Unit Conversion Power Save Mode Back-light ON/OFF Control Function
P TYPE : 341 (W) x 435 (D) x 474 (H)[mm] / 134 (W) x 171 (D) x 186 (H)[inch] B TYPE : 341 (W) x 383 (D) x 102 (H)[mm] / 134 (W) x 151 (D) x 40 (H)[inch] U TYPE : 341 (W) x 435 (D) x 474 (H)[mm] / 134 (W) x 171 (D) x 186 (H)[inch]
330 (W) x 235 (D)[mm] / 129.92 (W) x 92.52 (D)[inch]

Weight

2.8 kg

Power

1.5 V x 3 units (D size Battery), Pb 4V/4Ah, 6 V Adapter

Operation Time
Operating
Temperatur e

Approx. 300 hours (Manganese Battery) / 600 hours (Alkaline at 20 °C / 68 °F) / Backlight off
-10 °C ~ +40 °C / 14 °F ~ 104 °F

Option

RS232, USB, Manganese Battery, Pole Type

 Notice: Specifications are subject to change for improvement without notice.

22

23

24

25

26


GPL Ghostscript 9.55.0