Overview
The L510 Lamp Controller is designed for the hospitality industry to provide convenient switched and dimming control of several different load types, including; incandescent, CFL and LEDs. By doing this, it converts any standard lamp into a remotely controlled lamp with the ability to create scenic and mood lighting. The L510 is able to participate in Honeywell's overall Energy Management System (EMS) to provide energy savings along with enhanced guest experience. A typical application would include a L510 controlling scenic lighting around a headboard of a guestroom bed. To provide this control, the L510 is equipped with an INNCOM WBI relay, Triac or FET actuator and communicates via the on-board 2.4Ghz radio over the INNCOM DeepMesh network. The L510 which is controlling the lamp can be controlled by an INNCOM MODEVA or EVORA switch as well as also be controlled locally. Other applications include; desk and floor lamp control as well as wall sconce control. .

Part Numbers
PART NUMBERS

DESCRPTION

Figure 1 L510 Lamp Controller

201-7050

Relay Actuator RF Lamp Controller, 120-240VAC, 500W

201-7051

Triac Dimmer RF Lamp Controller, 120VAC, 650W

201-7052

FET Dimmer RF Lamp Controller, 120VAC, 350W

System Layout

1

Load Ratings

Model
201-7050 (Relay)
201-7051 (Triac)
201-7052 (FET)

Voltage 120-240 Vac 120-240 Vac 120-240 Vac 120-240 Vac 120-240 Vac 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac 120 Vac

Freq 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz

Rating Power / Amperes 4.1 A 4.1 A 500 W 250 VA 1/10 HP 2.9 A 2.9 A 650W 250 VA 1/10 HP 2.9 A 2.9 A 350 W 250 VA

Type of Load Resistive General Purpose Tungsten / ELV Electric Ballast Motor Resistive General Purpose Tungsten / ELV Electronic Ballast Motor Resistive General Purpose Tungsten / ELV Electronic Ballast

Product Specification

Parameter S5 Bus
DeepMesh RF I/O Power

Specification Data Rate Range Max Nodes Range Transmit Power Receive Sensitivity Protocol Frequency Band Channels Digital input / outputs Input Voltage Device Power Consumption Max DC Power

Environment Approvals

Operating Temperature Storage Temperature Humidity CFR47 FCC Part 15.247 Subpart C CR47 FCC Part 15 Subpart B RSS-247 Issue 2 ICES-003 Issue 6 RSS-Gen Issue 5 Rss-102 Issue 5

Range / Value 2550bps 50ft 20 70ft +5dBm -95dBm IEEE 802.15.4 2405MHz ­ 2480MHz 11-26 2 dry contact inputs / UART pins 120Vac 12VDC, 100mA 200mA (100mA available to power external device on 12Vdc) 0 -30C -10 ­ 50C 10 ­ 90% RH, Non-condensing

RJ-12 Low Voltage Connector

Pin Typical Color*

1

White

2

Black

3

Red

4

Green

5

Yellow

6

Blue

*Wire colors may differ

Function GND +12V S5 Bus INPUT 1 / UART- Tx INPUT 2 / UART - Rx NC

RJ-9 Switch Connector

Conformance statement
FCC ID: GTC-201705X
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
 Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
IC: 1609A-201705X
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the
device.
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
1. L'appareil ne doit pas produire de brouillage; 2. L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.

Wiring
CAUTION
!
 Only a trained, experienced service technician should install the L510. Before beginning, the installer should check the ratings given in the instructions and on the product to make sure the product is suitable for the application.
 The installer must disconnect the AC from the drape motor power supply before beginning the installation to prevent electrical shock or equipment damage.
 All wiring must comply with local codes and ordinances.
 The L510 is intended for INDOOR USE ONLY.
 It is important to read the instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.

Ordering Specifications
Model # 201-7050
201-7051
201-7052

Description L510 ­ Relay Lamp Controller L510 ­ Triac Lamp Controller L510 ­ FET Lamp Controller

Document Revision History

REVISION

DATE ISSUED

V0.2

12 -Feb-2021

REASON Added IC / FCC ID


Microsoft: Print To PDF