User Manual for MEDITECH models including: LED700 LED Shadowless Lamp, LED700, LED Shadowless Lamp, Shadowless Lamp, Lamp
5 sept. 2023 — The surface of the glass cover is often cleaned with medical gauze to increase the illuminance. Water can be used; alcohol and organic solvents are ...
Operating Lamp | Vet Surgical Supplies
File Info : application/pdf, 19 Pages, 1.04MB
DocumentDocumentLED Shadowless Lamp User Manual Tootoo Meditech Co., Ltd. Content Precautions, Warnings and Instructions.................................................................... 2 1.Product Name and Models ....................................................................................... 4 2.Application................................................................................................................. 4 3.Structure and Conponents ....................................................................................... 4 4.Specifications ............................................................................................................. 4 4.1 Operation Environment........................................................................................................... 4 4.2 Parameters .............................................................................................................................. 5 5. Label and Package Icons ......................................................................................... 6 6. Usage Instruction ..................................................................................................... 7 6.1 Installation............................................................................................................................... 7 6.2 Operation ................................................................................................................................ 8 6.3 Debugging ............................................................................................................................... 8 7. Maintenance ............................................................................................................. 9 8.Cleaning and Disinfection ........................................................................................ 9 8.1 Handle Sterilization ................................................................................................................. 9 8.2 Lamp Cover and Control Panel Sterilization ............................................................................ 9 9. Storage and Transportation .................................................................................... 9 10. Operating Lifetime............................................................................................... 10 11. Other Description ................................................................................................. 10 11.2 Safety instructions for the environment ............................................................................. 10 12. Troubleshooting.................................................................................................... 11 13. Configuration List................................................................................................ 11 14. Electromagnetic Compatibility ........................................................................... 12 1 Tootoo Meditech Co., Ltd. Precautions, Warnings and Instructions 1.Please read the instructions carefully before using this product. 2.Strictly follow the steps in the installation manual for installation and debugging. When connecting to the power supply, please use a 5A isolator. 3.Please check the LED shadowless lamp frequently to prevent accidents. 4.Personnel not approved by the company, please do not disassemble the product and power circuit at will. 5.This product provides lifetime maintenance service, the operating lifetime is 10 years and 1 year for the free warranty (except for bulbs). Improper use and causing damage of the product is not included in the free warranty. Repairing without permission is prohibited, otherwise company will not provide free warranty. Please use the spare parts and accessories provided by the manufacturer to ensure the safety and maintenance. 6.Use soft cloth or sponge, damp cloth or detergent for cleaning, do not use hard brush, wire brush, or corrosive liquids, such as wet paint or acids on shadowless lamp surface. 7.After using the detergent, please wipe the shadowless lamp with a damp cloth, and then dry it with a dry cloth. 8.The surface of the glass cover is often cleaned with medical gauze to increase the illuminance. Water can be used; alcohol and organic solvents are prohibited. 9. Steam sterilization can be used for lamp handle, with 121 in 30 minutes. Lamp cover and control pannel can be sterilized with 75% alcohol for 3 minutes or with 0.1% bromogeramine disinfectant for 30 minutes. 10.The spring arm of shadowless lamp is forbidden to hang other objects. 11.In order to ensure the normal use of this product, it is forbidden for non-professionals to open the lamp cover. 12. The operator should wear gloves when adjusting through the handle. 13. If the lamp bulb does not light up, turn off the power first, check whether the fuse is burnt out or not, and the fuse is positioned in the base shield, and change 2 Tootoo Meditech Co., Ltd. it (fuse: F2AL250V, 6.3mm, length 32mm). 14.The grounding wire should be well connected to the product grounding terminal.The grounding symbol: 15. This symbol means to consult the acoompanying documents. 16.In order to prevent staticelectricity, operator should lay the anti-static carpet and have an anti-static wristband, which is designed to safely ground operator working with sensitive components, preventing a build-up of static electricity. 3 Tootoo Meditech Co., Ltd. 1.Product Name and Models Product Name: LED Shadowless Lamp Product Models: LED700/700LED700/500LED700LED500D5D3TTOL-D5 2.Application Intended use: Professional Medical Lighting for Hospital, Clinic, Minor Surgery, Examination or Diagnosis, within suitable facilities designated for such purposes. This light system is mounted centrally in a room that access is available all around the operating environment. Misuses: For any purpose or use at any facility other that stated above. Caution shall be exercised when positioning the light head and avoid contact or collision with the patient, other medical professionals or other lights/equipment. 3.Structure and Conponents LED Shadowless Lamp has 3 components: lamp base, Balancing Spring Arm and Lamp Head. Lamp head has single lamp head or double lamp head. 4.Specifications 4.1 Operation Environment a)Environmental Temperature Range5 40 b)Relative Humidity Range80% c)Atmospheric Pressure Range700hPa 1060hPa d)Power Supply 220V, 50Hz There should be no harmful gas, chemical precipitation and other flammable, explosive, corrosive media or places close to heat sources that seriously affect the use of the LED surgical shadowless lamp, make sure the ventilation is good, and keep dry of the equipment. 4 Tootoo Meditech Co., Ltd. Cannot be used with high-frequency surgical equipment at the same time. Using the shadowless lamp closed to short-wave and microwave therapy equipment may cause the unstable output of the device. 4.2 Parameters Please refer to Table 1, Table 2, Table 3, and Table 4 for the operating range, push and pull force, optical performance, and main safety features of the LED shadowless lamp. Table1 Operating Range of LED Shadowless Lamp Moving Range items Rotating Arm Balancing Spring Arm (rotation) Spring Arm (up & down) Lamp Head Rotation Large C-arm Handle Small C-arm Handle LED700D5 360° 360° 80° 360° 180° 180° Model LED500D3 360° 360° 80° 360° 180° 180° Table2 Push and Pull Force of LED Shadowless Lamp Starting Force N items Lamp Head Handle Rotation Handle Installation Force LED700D5 25 10 Model LED500D3 25 10 Table3 Optical Performance of LED Shadowless Lamp Lamp Head Specification Parameter Central IlluminanceEc Spot Diameterd10 LED700D5 LED500D3 40000lx<Ec<160000lx 120mm Spot distribution d50mm 60mm Shadowless Effect Remaining central illuminance of single shutter lx Remaining central illuminance of double shutterslx 22000 32000 10000 23000 5 Tootoo Meditech Co., Ltd. Remaining central illuminance of cavitylx Remaining central illuminance of cavity with single shutterlx Remaining central illuminance of cavity with double shutterlx Beam Spread CRI (Color Rendering Index) Color Temperature Maximum IrradianceW/m2 60000 19000 20000 900 31000 8000 9000 800mm 85Ra100 3000KTc6700K 900 Table 4 Main Safety Features Classification Type of Protection Against Class I Electric Shock Degree of Ingress No applied part protection Ingress Protection Rating IP40 Degree of Safety for Usage Do not use with flammable anesthetic gases mixed with air or nitrous oxide Operating Mode Continue Power Rated Voltage and AC220V 50Hz Frequency Rated Power LED700/700 LED700/500D5400VA LED700LED500D3:200VA Fuse and Rated Voltage F2AL250V AC220V Note: The irradiance of the overlapping lighting area may exceed 1000W/m2, which may do harm to user's eyes. Please do not look directly at the spot of lamp. 5. Label and Package Icons Packaging and Labeling Explaination Symbol Meaning Symbol Alternating Current Meaning Grounding Afraid of Rain Beware of Burns 6 Tootoo Meditech Co., Ltd. Fragile Product Up Note: Please consult the accompanying documents before use. Please avoid looking directly at the light source for a long time. 6. Usage Instruction 6.1 Installation Installation Conditions 1)The places or environment provide go od ventilation and sanitary condition. 2) The power supply voltage is AC 220V 50Hz, and the connection between the equipment and the network power supply must have more than twice the capacity. 3)The safety factor of the suspension system of this product is 20 (4 M12 screws are used to fix the product, the load of a single screw is 1500kg, and the weight of the product is 120kg). 4)The installation foundation of the LED surgical shadowless lamp must be able to withstand a load of 500kg to prevent the LED shadowless lamp from falling. 5)Installation Environment meets the electromagnetic compatibility requirements. Installation Method The installation process is guided by our company's professional and technical personnel. Install and Remove Components Handle Installation make sure the positioning hole of handle is aligned with the buckle on the lamp head, and directly push the handle to the buckle. Handle RemovalPress and hold the connection buckle, remove the 7 handle directly. 6.2 Operation Tootoo Meditech Co., Ltd. 1, Long press the Power switch for 3 seconds to turn o n the shadowless lamp. Use the control pannel to adjust the lighting. Press the brightness+ can increase the brightness, and press the brightnessto decrease the brightness. Press the +K can increase the color temperature, and press the K to decrease the color temperature. 2.Rotate the focusing handle, adjust the spot size and focus depth to achieve the best lighting state for opertaion. 3. After each use, adjust the brightness and color temperature of the lamp to the weakest state, and long press the power button for 3 seconds to turn off the shadowless lamp. 6.3 Debugging 1. When adjusting each part, clockwise is to tighten and counterclockwise is to loosen. Each part can be rotated and positioned at a certain position flexibly and freely. If you have any questions, please contact the factory. 2. After installation, if the balancing arm and C-arm handles are not flexible or can not be positioned, use the 6mm hexagonal wrench to adjust the corresponding screw at the connection. 3. If the large C-arm handle and small C-arm handle are not flexible or can not be positioned, use the 4mm hexagonal wrench to adjust the corresponding screw at the connection. 4. If the small C-arm handle and lamp head are not flexible or can not be positioned, use the 4mm hexagonal wrench to adjust the corresponding screw at the connection. 8 Tootoo Meditech Co., Ltd. 5. If the vertical movement of balancing arm is not flexible or can not be positioned, use the 6mm hexagonal wrench to adjust the balancing spring. 7. Maintenance LED Shadowless Lamp needs regular maintenance by professional personal. Refer to Table5 and make a record. If any problem occurred, please refer the manual accordingly. If the problem still can not be solved, please contact our factory in time. Table5 Maintenance Period Item Frequency Check the status of each connection part Check the connection of power circuit Check the flexibility of all the moving parts every two months every two months every two months 8.Cleaning and Disinfection Before cleaning and disinfection, turn off the power first. Make sure no liquid penetrate into the lamp. Do not use the wire brush or any other abrasive materials. 8.1 Handle Sterilization Steam sterilization, Temperature: 121°C Time: 30 minutes. 8.2 Lamp Cover and Control Panel Sterilization 75% alcohol disinfection for 3 minutes or 0.1% bromogeramine disinfectant for 30 minutes. 9. Storage and Transportation · The lamp should be stored in a well-ventilated room with less than 80% of humidity,temperature range is 5 ~ ± 50 and no corrosive gases. · Please use the original packaging during transportation. The lamp is fragile and easily scratched or damaged by sharp or hard 9 objects, well-packaging is needed. Tootoo Meditech Co., Ltd. 10. Operating Lifetime Production Date refer label Safety operating lifetime: 10 yearsstart from production date Handle lifetime 15000 times (plug and unplug) 11. Other Description 11.1 The company may provide circuit diagrams, component list, calibration details as required, or necessary information that will assist technicians to repair equipment parts designated by the manufacturer. 11.2 Safety instructions for the environment 1. Disposal of packaging materials 1 Wooden box -- environmentally friendly and recyclable. Should be transported to designated recyclable materials storage points. 2 Styrene packaging and plastic bags----hazardous to the environment and should be transported to designated non-recyclable material storage points for further processing. 2. Disposal of equipment When the equipment has reached the end of its lifetime, it must be taken out of service. The dismantle equipment should be classified according to the different materials of the product components. 1) Metal parts -- environmentally friendly and recyclable. should be transported to the designated storage point. 2) Plastic parts -- harmful to the environment, should be transported to a designated non-recyclable material storage point for processing. 3) Glassware -- environmentally friendly and recyclable, should be transported to the designated storage point. 4) Electronic and electrical devices -- harmful to the environment and should be transported to designated storage point for processing. 10 Tootoo Meditech Co., Ltd. 12. Troubleshooting Refer Table 6 for common faults and solutions. NOTE: Any repairs of electrical circuit must be referred to qualified service personnel. Table6 Common Faults and Solutions No. Situation Solutions Turn on the external Check whether there is power supplied to the power switch, the lamp socket base. 1 power indicator of Check the safety device, if the safety tube is the control panel burnt out, replace a new one of the same type. will not light up Turn on the external Check the control power circuit. power switch, the Check whether the color of the wire is 2 control panel can connected correctly. not be operated 3 LED lamp do not work Check the lifetime of bulb and fuse. Replace bulb or fuse. 4 LED lamp rotates Installation is not in horizontal level or the brake non-stop part is too loose. Adjust the level to reinstall, or adjust the brake screw. 5 The brightness of lamp The external voltage is low is not enough Check the voltage with multimeter 6 The vertical movement Balancing spring is loose or tight of lamp head can not be Open the cover and adjust the screw. Clockwise is for positioned tighten, counterclockwise is for loosen. 13. Configuration List No. Name 1 lamp base 2 balancing arm 3 lamp head 4 handle 5 certificate 6 user manual 11 Quantity 1 1 or 2 1 or 2 2 1 1 Remark 7 warranty card 8 packing list Tootoo Meditech Co., Ltd. 1 1 14. Electromagnetic Compatibility 1. Before installation and operation, please refer to the electromagnetic compatibility information. 2. Use the connection cable and switch provided by our company. The power cord used in this equipment has passed the "CCC" certification. 3. Warning: In addition to the connecting cables and switches provided by our company, using other manufacturers'accessories may lead to increased emissions or reduced immunity. 4. In order to ensure that the shadowless lamp can be used normally and that their emission is not increased and their immunity is not reduced, please use the connecting cables and related accessories provided by our company. 5. Using unspecified accessories, transducers or cables with the shadowless lamp may lead to an increasing emissions or a decrease in immunity. 6. The shadowless lamp should not be used with other devices with the same or similar operating frequency. If they must be used at the same time, you should observe and verify whether they can be operated normally. 7.When the beam is not blocked by anything, the central illuminance of each lamp head should reach 40000lx, and should not exceed 160000lx. 8. Portable and mobile radio frequency communication devices may affect the use of the lamp. Ensure the normal use of the lamp, it is recommended to stay away from portable and mobile radio frequency communication devices or keep them turned off. 12 9.Cable information No. Cable name 1 Power cable Tootoo Meditech Co., Ltd. Lengthm 1.5 whether to shield No Table 201 Guidance and Manufacturer's Declaration--Electromagnetic Emissions Shadowless lamp is expected to be used in the electromagnetic environment specified as below, user should ensure the operating environment. Emission Test Compliance Electromagnetic Environment-Guidance Radio Frequency GB 4824 Shadowless lamp use RF energy for its internalfunction. Therefore, the radio 1 group frequency emissions are very low and less likely to cause interference in electronic equipment nearby. Radio Frequency GB 4824 Class A Shadowless lamp are suitable for non-domestic Harmonic Emission GB 17625.1 N/A and low voltage power indirect supply Voltage fluctuation/flicker N/A GB 17625.2 networks. Table 202 Guidance and Manufacturer's Declaration-Electromagnetic Immunity The shadowless lamp is expected to be used in the electromagnetic environmnet specified below, and the user should ensure that it is used in this electromagnetic environment. Immunity test ICE60601 Testing Test Level Guidance-Electromagnetic Environment Electrostatic ± 6KV contact ± 6KV contact The floor should be made of wood, Discharge (ESD) GB/T17626.2 discharge ± 8KV discharge air ± 8KV concrete, or ceramic tiles. If the floor air is covered with synthetic materials, the discharge discharge relative humidity should be at least 30%. Electrical Fast ±2KV power line ±2KV power line The network power supply should have the Transient (EFT) quality typical of commercial or 13 Tootoo Meditech Co., Ltd. GB/T17626.4 Electrical Surge ±1KV ±1KV hospital environments The network power supply should have the GB/T17626.5 line-to-line ±2KV line-to-line ±2KV quality typical of commercial or hospital environments line-to-ground line-to-ground Temporary voltage <5% UT, lasting <5% UT, lasting drops, brief 0.5 cycles (95% 0.5 cycles (95% The network power supply should havve the interruption, and voltage dip on UT) voltage dip on UT) quality typical of commercial or voltage fluctuations At 40% UT, lasting At 40% UT, lasting hospital environments on the power input line 5 cycles (60% 5 cycles (60% It is recommended for user of shadowless GB/T17626.11 voltage dip on UT) voltage dip on UT) lamp who require continuous operation At 70% UT, lasting At 70% UT, lasting during power interruptions to use an 25 cycles (30% 25 cycles (30% uninterruptible power supply (UPS) for voltage dip on UT) voltage dip on UT) power supply <5% UT, lasting 5 <5% UT, lasting 5 seconds (Voltage seconds (Voltage dip >90% on UT) dip >90% on UT) Power frequency magnetic field50Hz 3A/m 3A/m The power frequency magnetic field should have typical levels and GB/T17626.8 characteristics found in commercial or hospital environments Note: "UT"refers to the AC grid voltage before applying the test voltage Table 204 Guidance and Manufacturer's Declaration-Electromagnetic Immunity The shadowless lamp is expected to be used in the electromagnetic environmnet specified below, and the user should ensure that it is used in this electromagnetic environment. Immunity test ICE60601 Testing Test Level Guidance-Electromagnetic Environment 14 RF conduction GB/T17626.6 3VRMS value 150kHz80MHz RF radiation GB/T17626.3 3V/m 80MHz2.5GHz Tootoo Meditech Co., Ltd. Portable and mobile RF communication devices should not be positioned closer to any part of the shadowless lamp than the recommended isolation distance, including cables. The calculation of 3VRMS value the distance should use the formula corresponding to the transimtter. Recommended isolation distance: 3V/m d=1.2 P d=1.2 P 80MHz800MHz d=2.3 P 800MHz2.5GHz In the formula P-Maximum rated output power of the transmitter provided by the transmitter manufacturer, measured in watts (W) d-Recommended isolation distance, measured in meters (m) The field strength of fixed RF transmitters, determined by surveying the electromagnetic field at location a, should be lower than the compliant levels in each frequency range b Interference may occur near devices marked with the following symbols 15 Tootoo Meditech Co., Ltd. Note 1For frequencies at 80MHz and 800MHz, the formula for the higher frequency range should be used. Note 2These guidelines may not be applicable to all situations. Electromagnetic progagation is influenced by the absorption and reflection of buildings, objects, and human bodies. a. Fixed RF transmitters such as wireless (cellular/cordless) telephones, ground-based mobile radio broadcasts, have unpredictable field strengths that cannot be accurately determined theoretically. To assess the electromagnetic environment of fixed RF transmitters, an electromagnetic field survey should be conducted. If the measured field strengh at the location of the surgical shadowless lamp exceeds the aforementioned RF compliance levels, the performance of the shadowless lamp should be observed to verify its proper operation. If abnormal performance is observed, supplementary measures may be necessary, such as repositioning or reorienting the surgical shadowless lamp. b. Across the entire frequency range of 150kHz to 80MHz, the field strength should be below 3V/m. Table 206 Recommended isolation distance between portable and mobile RF communication equipment and surgical shadowless lamp The shadowless lamp is intended to be used in an electromagnetic environment with controlled radiation disturbances. Based on the maximum output power of the communication equipment, users can prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication devices and this medical device. Maximum rated output The isolation distance corresponding to different frequencies of the power of the transmitter transimitter: 150kHz80MHz 80MHz800MHz 800MHz2.5GHz W d=1.2 P d=1.2 P d=2.3 P 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 16 Tootoo Meditech Co., Ltd. 100 12 12 23 For maximum rated output power of the transmitter not listed in the table, the recommended isolation distance (d) in meters (m) can be determined using the formula in the corresponding transmitter frequency column, where P is the maximum rated output power of the transmitter provided by the transmitter manufacturer, measured in watts (W). Note 1For frequencies at 80MHz and 800MHz, the formula for the higher frequency range should be used. Note 2These guidelines may not be applicable to all situations. Electromagnetic progagation is influenced by the absorption and reflection of buildings, objects, and human bodies. 17 Tootoo Meditech Co., Ltd. Address: 3A, Phase II, Smart Home, Baolong Street, Longgang District, Shenzhen, Guangdong, China Tel: +86-755-28306385 Email:info@newtootoo.com Web: www.newtootoo.com