User Guide for EATON models including: SMART1000PSRTNC, SMART1000PSRTNC Line Interactive Pure Sine Wave Cloud Connected UPS, SMART1000PSRTNC, Line Interactive Pure Sine Wave Cloud Connected UPS, Pure Sine Wave Cloud Connected UPS, Cloud Connected UPS, Connected UPS, UPS
15 mag 2025 — Quick Start Guide. ○. 1 / 6. Page 2. Specifications. Seamless Connectivity for ... Storage Temperature Range. 5° to 122°F (-15° to 50°C). Relative Humidity.
New Products | Eaton
File Info : application/pdf, 6 Pages, 64.49KB
DocumentDocument1000VA 750W 120V Line-Interactive Pure Sine Wave Cloud-Connected UPS with Remote Monitoring - 10 NEMA 5-15R Outlets (Surge and Battery Backup), LCD, 5-15P Plug, Tower MODEL NUMBER: SMART1000PSRTNC Line-interactive pure sine wave UPS with included remote monitoring software provides 24/7 access and control of any size deployment via mobile app or web browser. Features 1000VA/750W/120V Pure Sine Wave Battery Backup for Sensitive Devices The SMART1000PSRTNC line-interactive cloud-connected UPS system combines cloud connectivity, remote management and advanced protection features. Its slim tower design is suitable for desktop or floor placement or installed in a rack (with optional mounting kit, sold separately). It's recommended for home, office and retail use, as well as network closets in both local and remote locations. Easy-to-Use Cloud-Enabled Remote Monitoring Powered by Brightlayer Eaton's cloud-based remote monitoring app offers convenient setup, control and management of a single UPS or a larger deployment. Scan the QR code on the UPS to download the app to your mobile device. Receive alerts, push configurations, silence alarms or control load banks using a mobile app or web browser. Being able to monitor and access multiple UPS systems from a remote location helps reduce the number of site visits, saving you time and money. The unit's NFC (near-field communication) feature lets you configure network settings instantly from your mobile device. Allows Time to Back Up Critical Files During a Blackout During short blackouts, the SMART1000PSRTNC switches to battery power to keep connected equipment running. This allows you enough time to save data and complete a safe shutdown in case of a longer outage. Once AC power is restored, the SMART1000PSRTNC restarts automatically, regardless of battery charge level, saving you a costly site visit. NEMA 5-15R Outlets and Controllable Load Banks Protect Connected Components Ten 5-15R outlets provide battery backup and surge protection for your security camera, router, network switch, server and other sensitive electronic devices. Remote monitoring allows individual control of three switchable load banks that can be powered on/off or cycled remotely, saving you an expensive and timeconsuming on-site visit. Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts and overvoltages. The SMART1000PSRTNC can correct brownouts as low as 97V and overvoltages as high as 145V back to nominal 120V power continuously, all while keeping the battery fully charged and ready to take over in case of power failure. 1 / 6 Highlights Delivers pure sine wave power to ensure reliable protection for sensitive electronics Cloud-connected dashboard allows 24/7 remote monitoring via browser or mobile app Create your account with twofactor authentication for an additional layer of security Quick setup in minutes via mobile app gets your connected devices protected right away NFC technology allows easy configuration of network settings from your mobile device Switchable load banks let you control or reboot devices using the mobile app Package Includes SMART1000PSRTNC 1000VA 750W 120V Line-Interactive Pure Sine Wave CloudConnected UPS Quick Start Guide Seamless Connectivity for Advanced Remote Monitoring and Configuration An RJ45 port for Ethernet connectivity enables use of the cloud-based remote monitoring application. A USB-C port provides direct connection to the command line interface (CLI) for configuration and identification of local network parameters. Intuitive LCD, Home-Friendly Alarm and Diagnostic LEDs Keep You Informed 24/7 The easy-to-read LCD and two status LEDs allow at-a-glance local monitoring of UPS status, voltage, load level, battery level and other vital information. A solid green LED means the battery is charged, a flashing green indicates it is charging and a solid red indicates fault. The audible alarm indicates power outage, low-battery and fault conditions. It can be silenced via the LCD or the remote monitoring app, which will still respond to silenced alarms. Optional Mounting Kit Allows Rack Installation With the optional RKTRYPSC rack-mounting kit (sold separately), you can install the SMART1000PSRTNC in 2U of space in a 2-post or 4-post rack. Easy Preventative Maintenance and Initial Troubleshooting The SMART1000PSRTNC's self-test capability and user-replaceable internal battery can extend the life of the UPS and minimize disruption to operations. A resettable circuit breaker on the rear of the UPS helps prevent dangerous system overloads. Specifications OVERVIEW UPC Code UPS Type 037332283757 Line-Interactive INPUT Input Phase Single-Phase Rated input current (Maximum Load) 9A Nominal Input Voltage(s) Supported 120V AC UPS Input Connection Type 5-15P Input Circuit Breakers 10A UPS Input Cord Length (ft.) 5 UPS Input Cord Length (m) 1.5 Recommended Electrical Service 15A 120V Input Connection Type NEMA 5-15P Input Frequency 50/60 +/- 3Hz Auto-sensing Input Plug Type NEMA 5-15P Input Cord Length (ft.) 5 Input Cord Length (m) 1.52 OUTPUT Output Capacity (VA) Output Capacity (kVA) 1000 1 2 / 6 Output Capacity (Watts) 750 Output Capacity (kW) 0.75 Power Factor 0.75 Nominal Voltage Details 120V Frequency Compatibility 50 / 60 Hz Output Voltage Regulation (Line Mode) 120V (±10%) Output Voltage Regulation (Battery Mode) 120V (±10%) Load Management Receptacles 3 Load Banks: Load Bank 1: 2 outlets Load Bank 2: 2 outlets Load Bank 1: 4 outlets Output AC Waveform (AC Mode) Sine wave Output (Watts) 7501 Output AC Waveform (Battery Mode) Pure Sine wave Nominal Output Voltage(s) Supported 120V Output Receptacles (10) 5-15R Overload Protection (Line Mode) 110%+15%/-5%,go to fault after 5min, 120%+15%/-5%,go to fault immediately (Battery Mode) 110%+15%/-5%,Shutdown in 10 seconds, 120%+15%/-5%,Shutdown immediately Customized Load Management Receptacles 3 BANKS: Load Bank 1: 2 outlets Load Bank 2: 2 outlets Load Bank 3: 4 outlets Individually Controllable Load Banks Yes BATTERY Battery Type Runtime Full Load (min.) Runtime Half Load (min.) Expandable Runtime DC System Voltage (VDC) Battery Recharge Rate (Included Batteries) Battery Access Valve Regulated Lead Acid (VRLA) 1.8 min. (750W) 10 min. (375W) No 24 Less than 8 hours from 10% to 90% Battery Access Door VOLTAGE REGULATION Voltage Regulation Description Overvoltage Correction Undervoltage Correction Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 97V to 145V Input voltages between 132 and 145 are reduced by 10% Input voltages between 97 and 108 are boosted by 11.5% USER INTERFACE, ALERTS & CONTROLS Diagnostic LED(s) Yes 3 / 6 Front Panel LCD Display Switches Alarm Cancel Operation Audible Alarm LED Indicators Backlighted LCD screen offers detailed UPS status and operational information including Input Voltage, Output Voltage, Estimated Runtime (minutes), Output Load Percentage, Output Load Wattage, Battery Voltage, Graphical 4-Bar Battery Charge level and 4 bar load Level. LCD screen also shows UPS status AC Powered or battery operation, Alarm muted (icon flashing) & Alarm disabled (icon steady on). ON/OFF/MODE button provides UPS on/off power control (long-press); MUTE/ENTER allows alarm to be muted (long press), and advances the LCD screen display (short tap) Press the MUTE/ENTER button during a power failure to silence the alarm; Once silenced, alarm will re-sound to indicate low-battery status Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions Green and Red LEDs. Solid green slows AC operation, flashing green shows AC operation and battery charging. Red LED indicates a UPS fault. SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating UPS AC Suppression Response Time EMI / RFI AC Noise Suppression 156 Instantaneous Yes PHYSICAL Primary Form Factor Tower Rack Height 2U Cooling Method Fan Minimum Required Rack Depth (cm) 45.72 Minimum Required Rack Depth (inches) 18 Optional Mounting Accessory Notes Can be mounted to 2 and 4 post racks via optional rackmount shelf kit. Primary UPS Depth (mm) 390 Primary UPS Height (mm) 315 Primary UPS Width (mm) 86 Shipping Dimensions (hwd / in.) 18.80 x 6.60 x 16.30 Shipping Weight (kg) 12.61 UPS Housing Material ABS UPS Power Module Dimensions (hwd, in.) 12.402 x 3.386 x 15.354 UPS Power Module Weight (kg) 11.79 UPS Power Module Weight (lbs.) 26 Unit Dimensions (hwd / in.) 15.400 x 3.386 x 12.400 Unit Weight (lbs.) 26 Unit Weight (kg) 11.79 ENVIRONMENTAL Operating Temperature Range 32° to 104°F (0° to 40°C) 4 / 6 Storage Temperature Range Relative Humidity AC Mode BTU / Hr. (Full Load) AC Mode Efficiency Rating (100% Load) Operating Elevation Audible Noise 5° to 122°F (-15° to 50°C) Up to 90%, non-condensing 41 95.16% 9842 40dB at 1 meter COMMUNICATIONS Network Monitoring Port Description The UPS models support Free access to Eaton's cloud-based Brightlayer® Remote Monitoring App for quick and easy setup, control and management, for one or multiple device deployment. Network Management Card Description Network management card included Communications Interface Included network card; Near Field Communication (NFC); RJ45 Network; USB-C LINE / BATTERY TRANSFER Transfer Time Low Voltage Transfer to Battery Power (Setpoint) High Voltage Transfer to Battery Power (Setpoint) 6ms typical, 10ms max 97V +/- 3% 145V +/- 3% FEATURES & SPECIFICATIONS Cold Start (Startup in Battery Mode During a Power Failure) High Availability UPS Features Green Energy-Saving Features Cold Start Cold-start operation supported Automatic Voltage Regulation (AVR); Pure sine wave output; Remote management; Sine wave output; Surge/noise protection Individually controllable load banks Cold-start operation supported APPLICATIONS UPS Applications Retail/Point of Sale; Hospitality; High-End Desktop/Small Network; Large Network STANDARDS & COMPLIANCE Product Certifications Product Compliance CSA (Canada); NOM (Mexico); UL 1778 ENERGY STAR Qualified; FCC Part 15 Class B (USA); RoHS WARRANTY & SUPPORT Product Warranty Period (U.S. & Canada) Product Warranty Period (Latin America) Product Warranty Period (International) 3-year limited warranty 3-year limited warranty 2-year limited warranty 5 / 6 Product Warranty Period (Mexico) Connected Equipment Insurance (U.S., Canada & Puerto Rico) 3-year limited warranty $250,000 <a class="insuranceLink" href="//tripplite.eaton.com/support/insurance-policy">Ultimate Lifetime Insurance</a> 1000 Eaton Boulevard Cleveland, OH 44122 United States https://tripplite.eaton.com © 2025 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are the property of their respective owners. 6 / 6