User Guide for EATON models including: SMART1000PSRTNC, SMART1000PSRTNC Line Interactive Pure Sine Wave Cloud Connected UPS, SMART1000PSRTNC, Line Interactive Pure Sine Wave Cloud Connected UPS, Pure Sine Wave Cloud Connected UPS, Cloud Connected UPS, Connected UPS, UPS

1000VA 750W 120V Line-Interactive Pure Sine Wave ...

15 mag 2025 — Quick Start Guide. ○. 1 / 6. Page 2. Specifications. Seamless Connectivity for ... Storage Temperature Range. 5° to 122°F (-15° to 50°C). Relative Humidity.

Download PDF

New Products | Eaton


File Info : application/pdf, 6 Pages, 64.49KB

PDF preview unavailable. Download the PDF instead.

smart1000psrtnc
1000VA 750W 120V Line-Interactive Pure Sine Wave Cloud-Connected UPS with Remote Monitoring - 10 NEMA 5-15R Outlets (Surge and Battery Backup), LCD, 5-15P Plug, Tower
MODEL NUMBER: SMART1000PSRTNC
Line-interactive pure sine wave UPS with included remote monitoring software provides 24/7 access and control of any size deployment via mobile app or web browser.
Features
1000VA/750W/120V Pure Sine Wave Battery Backup for Sensitive Devices The SMART1000PSRTNC line-interactive cloud-connected UPS system combines cloud connectivity, remote management and advanced protection features. Its slim tower design is suitable for desktop or floor placement or installed in a rack (with optional mounting kit, sold separately). It's recommended for home, office and retail use, as well as network closets in both local and remote locations.
Easy-to-Use Cloud-Enabled Remote Monitoring Powered by Brightlayer Eaton's cloud-based remote monitoring app offers convenient setup, control and management of a single UPS or a larger deployment. Scan the QR code on the UPS to download the app to your mobile device. Receive alerts, push configurations, silence alarms or control load banks using a mobile app or web browser. Being able to monitor and access multiple UPS systems from a remote location helps reduce the number of site visits, saving you time and money. The unit's NFC (near-field communication) feature lets you configure network settings instantly from your mobile device.
Allows Time to Back Up Critical Files During a Blackout During short blackouts, the SMART1000PSRTNC switches to battery power to keep connected equipment running. This allows you enough time to save data and complete a safe shutdown in case of a longer outage. Once AC power is restored, the SMART1000PSRTNC restarts automatically, regardless of battery charge level, saving you a costly site visit.
NEMA 5-15R Outlets and Controllable Load Banks Protect Connected Components Ten 5-15R outlets provide battery backup and surge protection for your security camera, router, network switch, server and other sensitive electronic devices. Remote monitoring allows individual control of three switchable load banks that can be powered on/off or cycled remotely, saving you an expensive and timeconsuming on-site visit.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts and overvoltages. The SMART1000PSRTNC can correct brownouts as low as 97V and overvoltages as high as 145V back to nominal 120V power continuously, all while keeping the battery fully charged and ready to take over in case of power failure.
1 / 6

Highlights
 Delivers pure sine wave power to ensure reliable protection for sensitive electronics
 Cloud-connected dashboard allows 24/7 remote monitoring via browser or mobile app
 Create your account with twofactor authentication for an additional layer of security
 Quick setup in minutes via mobile app gets your connected devices protected right away
 NFC technology allows easy configuration of network settings from your mobile device
 Switchable load banks let you control or reboot devices using the mobile app
Package Includes
 SMART1000PSRTNC 1000VA 750W 120V Line-Interactive Pure Sine Wave CloudConnected UPS
 Quick Start Guide

Seamless Connectivity for Advanced Remote Monitoring and Configuration An RJ45 port for Ethernet connectivity enables use of the cloud-based remote monitoring application. A USB-C port provides direct connection to the command line interface (CLI) for configuration and identification of local network parameters.
Intuitive LCD, Home-Friendly Alarm and Diagnostic LEDs Keep You Informed 24/7 The easy-to-read LCD and two status LEDs allow at-a-glance local monitoring of UPS status, voltage, load level, battery level and other vital information. A solid green LED means the battery is charged, a flashing green indicates it is charging and a solid red indicates fault. The audible alarm indicates power outage, low-battery and fault conditions. It can be silenced via the LCD or the remote monitoring app, which will still respond to silenced alarms.
Optional Mounting Kit Allows Rack Installation With the optional RKTRYPSC rack-mounting kit (sold separately), you can install the SMART1000PSRTNC in 2U of space in a 2-post or 4-post rack.
Easy Preventative Maintenance and Initial Troubleshooting The SMART1000PSRTNC's self-test capability and user-replaceable internal battery can extend the life of the UPS and minimize disruption to operations. A resettable circuit breaker on the rear of the UPS helps prevent dangerous system overloads.
Specifications

OVERVIEW UPC Code UPS Type

037332283757 Line-Interactive

INPUT

Input Phase

Single-Phase

Rated input current (Maximum Load) 9A

Nominal Input Voltage(s) Supported 120V AC

UPS Input Connection Type

5-15P

Input Circuit Breakers

10A

UPS Input Cord Length (ft.)

5

UPS Input Cord Length (m)

1.5

Recommended Electrical Service

15A 120V

Input Connection Type

NEMA 5-15P

Input Frequency

50/60 +/- 3Hz Auto-sensing

Input Plug Type

NEMA 5-15P

Input Cord Length (ft.)

5

Input Cord Length (m)

1.52

OUTPUT Output Capacity (VA) Output Capacity (kVA)

1000 1

2 / 6

Output Capacity (Watts)

750

Output Capacity (kW)

0.75

Power Factor

0.75

Nominal Voltage Details

120V

Frequency Compatibility

50 / 60 Hz

Output Voltage Regulation (Line Mode)

120V (±10%)

Output Voltage Regulation (Battery Mode)

120V (±10%)

Load Management Receptacles

3 Load Banks: Load Bank 1: 2 outlets Load Bank 2: 2 outlets Load Bank 1: 4 outlets

Output AC Waveform (AC Mode)

Sine wave

Output (Watts)

7501

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

120V

Output Receptacles

(10) 5-15R

Overload Protection

(Line Mode) 110%+15%/-5%,go to fault after 5min, 120%+15%/-5%,go to fault immediately (Battery Mode) 110%+15%/-5%,Shutdown in 10 seconds, 120%+15%/-5%,Shutdown immediately

Customized Load Management Receptacles

3 BANKS: Load Bank 1: 2 outlets Load Bank 2: 2 outlets Load Bank 3: 4 outlets

Individually Controllable Load Banks Yes

BATTERY Battery Type Runtime Full Load (min.) Runtime Half Load (min.) Expandable Runtime DC System Voltage (VDC) Battery Recharge Rate (Included Batteries) Battery Access

Valve Regulated Lead Acid (VRLA) 1.8 min. (750W) 10 min. (375W) No 24 Less than 8 hours from 10% to 90% Battery Access Door

VOLTAGE REGULATION Voltage Regulation Description Overvoltage Correction Undervoltage Correction

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 97V to 145V Input voltages between 132 and 145 are reduced by 10% Input voltages between 97 and 108 are boosted by 11.5%

USER INTERFACE, ALERTS & CONTROLS

Diagnostic LED(s)

Yes

3 / 6

Front Panel LCD Display
Switches Alarm Cancel Operation Audible Alarm LED Indicators

Backlighted LCD screen offers detailed UPS status and operational information including Input Voltage, Output Voltage, Estimated Runtime (minutes), Output Load Percentage, Output Load Wattage, Battery Voltage, Graphical 4-Bar Battery Charge level and 4 bar load Level. LCD screen also shows UPS status AC Powered or battery operation, Alarm muted (icon flashing) & Alarm disabled (icon steady on).
ON/OFF/MODE button provides UPS on/off power control (long-press); MUTE/ENTER allows alarm to be muted (long press), and advances the LCD screen display (short tap)
Press the MUTE/ENTER button during a power failure to silence the alarm; Once silenced, alarm will re-sound to indicate low-battery status
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Green and Red LEDs. Solid green slows AC operation, flashing green shows AC operation and battery charging. Red LED indicates a UPS fault.

SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
UPS AC Suppression Response Time
EMI / RFI AC Noise Suppression

156 Instantaneous Yes

PHYSICAL

Primary Form Factor

Tower

Rack Height

2U

Cooling Method

Fan

Minimum Required Rack Depth (cm) 45.72

Minimum Required Rack Depth (inches)

18

Optional Mounting Accessory Notes Can be mounted to 2 and 4 post racks via optional rackmount shelf kit.

Primary UPS Depth (mm)

390

Primary UPS Height (mm)

315

Primary UPS Width (mm)

86

Shipping Dimensions (hwd / in.)

18.80 x 6.60 x 16.30

Shipping Weight (kg)

12.61

UPS Housing Material

ABS

UPS Power Module Dimensions (hwd, in.)

12.402 x 3.386 x 15.354

UPS Power Module Weight (kg)

11.79

UPS Power Module Weight (lbs.)

26

Unit Dimensions (hwd / in.)

15.400 x 3.386 x 12.400

Unit Weight (lbs.)

26

Unit Weight (kg)

11.79

ENVIRONMENTAL Operating Temperature Range

32° to 104°F (0° to 40°C)

4 / 6

Storage Temperature Range Relative Humidity AC Mode BTU / Hr. (Full Load) AC Mode Efficiency Rating (100% Load) Operating Elevation Audible Noise

5° to 122°F (-15° to 50°C) Up to 90%, non-condensing 41 95.16% 9842 40dB at 1 meter

COMMUNICATIONS

Network Monitoring Port Description The UPS models support Free access to Eaton's cloud-based Brightlayer® Remote Monitoring App for quick and easy setup, control and management, for one or multiple device deployment.

Network Management Card Description

Network management card included

Communications Interface

Included network card; Near Field Communication (NFC); RJ45 Network; USB-C

LINE / BATTERY TRANSFER
Transfer Time
Low Voltage Transfer to Battery Power (Setpoint)
High Voltage Transfer to Battery Power (Setpoint)

6ms typical, 10ms max 97V +/- 3% 145V +/- 3%

FEATURES & SPECIFICATIONS Cold Start (Startup in Battery Mode During a Power Failure) High Availability UPS Features
Green Energy-Saving Features Cold Start

Cold-start operation supported
Automatic Voltage Regulation (AVR); Pure sine wave output; Remote management; Sine wave output; Surge/noise protection Individually controllable load banks Cold-start operation supported

APPLICATIONS UPS Applications

Retail/Point of Sale; Hospitality; High-End Desktop/Small Network; Large Network

STANDARDS & COMPLIANCE Product Certifications Product Compliance

CSA (Canada); NOM (Mexico); UL 1778 ENERGY STAR Qualified; FCC Part 15 Class B (USA); RoHS

WARRANTY & SUPPORT
Product Warranty Period (U.S. & Canada)
Product Warranty Period (Latin America)
Product Warranty Period (International)

3-year limited warranty 3-year limited warranty 2-year limited warranty

5 / 6

Product Warranty Period (Mexico)
Connected Equipment Insurance (U.S., Canada & Puerto Rico)

3-year limited warranty
$250,000&nbsp;<a class="insuranceLink" href="//tripplite.eaton.com/support/insurance-policy">Ultimate Lifetime Insurance</a>&nbsp;

1000 Eaton Boulevard Cleveland, OH 44122 United States https://tripplite.eaton.com

© 2025 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks
are the property of their respective owners.

6 / 6



References

iTextSharp™ 5.5.13.2 ©2000-2020 iText Group NV (AGPL-version); modified using iTextSharp™ 5.5.13.2 ©2000-2020 iText Group NV (AGPL-version)