DocumentDocumentRF/TP media coupler/repeater RF/TP media coupler/repeater Order no.: 5110 00 Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully. The radio communication takes place via a non-exclusively available transmission path, and is therefore not suitable for safety-related applications, such as emergency stop and emergency call. These instructions are an integral part of the product, and must remain with the end customer. 2 Device components Figure 1: Device components (1) KNX connection (TP) (2) Programming button (3) Status LED Red flashing quickly: Filter function deactivated Red flashing slowly: Safe-state mode active Yellow flashing: Telegram traffic (4) Antenna (RF) 3 Function System information This device is a product of the KNX system and complies with the KNX directives. Detailed technical knowledge obtained in KNX training courses is a prerequisite to proper understanding. The range of a radio system depends on various external circumstances. The range can be optimised by the choice of installation location. The product documentation for this device contains application basics for the KNX radio system. Planning, installation and commissioning are carried out using ETS version 5 or higher. You can find the up-to-date product database, technical descriptions and Declaration of Conformity on our Internet site. 32591112 10867569 25.02.2020 1 / 5 RF/TP media coupler/repeater The device is KNX Data Secure compatible from version "I01". KNX Data Secure offers protection against manipulation in building automation and can be configured in the ETS project. Detailed specialist knowledge is required. Overview of device versions Devices with marking "I00": no KNX Data Secure compatibility. Secure commissioning of other devices via media coupler is not possible with this device version. Devices with marking "I01" or higher: KNX Data Secure compatibility from ETS5.7.3. Secure commissioning of other devices via media coupler is possible without restrictions from this device version. The devices are update-capable. Firmware updates (e.g. I00 -> I01) can be carried out conveniently using a special ETS application program. See the technical documentation for details. Simplified Declaration of Conformity Hereby Gira Giersiepen GmbH & Co. KG declares that the radio system type Order no. 5110 00 corresponds to the directive 2014/53/EU. You can find the full article number on the device. The complete text of the EU Declaration of Conformity is available under the Internet address: www.gira.de/konformitaet Intended use Connection of KNX radio networks with grid-bound KNX lines Increasing radio range in KNX radio networks (repeater operation) Mounting in appliance box according to DIN 49073 Figure 2: Media coupler and RF participant Figure 3: Media coupler and RF participant, supplemented by repeater (5) Media coupler (6) KNX power supply with throttle 32591112 10867569 25.02.2020 2 / 5 RF/TP media coupler/repeater (7) Repeater (8) Power supply 4 Operation as media coupler The physical address of the media coupler is the address of a line or a backbone coupler x.y.0 and must match the logical topology of the KNX system. Observe the instructions in the technical documentation regarding the address. Power is supplied via the KNX bus cable. With operation as a media coupler, the repeater function can also be activated. 5 Operation as repeater The physical address of the radio repeater is the address of a normal KNX participant x.y.z (z0) within the address range of the KNX radio system. Observe the instructions in the technical documentation regarding the address. Power is supplied via a separate power supply (accessory) or via the connection to a KNX line. Do not use the 30 V output of a KNX power supply. The media coupler may heat up to an impermissible temperature. Repeater mode is active after the physical address is assigned. Once this happens, programming via bus line is blocked. Then the device can only be reached by radio. To address the device via the bus line, reset the device to default settings. 6 Information for electrically skilled persons DANGER! Electrical shock on contact with live parts in the installation environment. Electrical shocks can be fatal. Before working on the device, disconnect the power supply and cover up live parts in the working environment. 6.1 Fitting and electrical connection Mounting and connecting the device Mount in flush-mounted or surface appliance boxes. In outdoor installations: Use appliance box IP55. Do not lead any wire cables from other power circuits through the appliance box. Do not lead any other sheathed cables through the appliance box. Operation as media coupler: Connect device to KNX bus cable via a bus terminal. Operation as repeater: Connect the device to a separate power supply via a bus terminal. Place the device in the appliance box. When laying the antenna, extend the antenna extended as much as possible. If this is not possible, position the antenna behind the device in a circular arrangement. When using blank covers, make sure the antenna does not lie directly behind the metal supporting frame. 32591112 10867569 25.02.2020 3 / 5 RF/TP media coupler/repeater Selecting installation location To ensure good transmission quality, keep a sufficient distance from any possible sources of interference, e.g. metallic surfaces, microwave ovens, hi-fi and TV systems, ballasts or transformers. Do not mount the media coupler near the earth or ground. Do not place KNX RF devices in metallic small distribution boards or boxes. If several adjacent media couplers are used, place them so their radio ranges either do not overlap at all, or so they can receive each other. Check within a system to see if a media coupler can be configured as a repeater. Media couplers must be accessible even after installation. 6.2 Commissioning Load physical address and application program Precondition: Device has been connected and the power is switched off. Press the programming button. The status LED lights up red. Download the physical address and domain address. The status LED goes out. Download the filter table and parameters. Reset the media coupler to default settings Disconnect device from bus or power supply. Press and hold programming button (2). Connect device to bus and/or switch on power. The status LED (3) flashes red slowly. The device is in safe-state mode. Release the programming button. Press programming button (2) again and hold about 20 seconds until status LED goes out. Release the programming button. The status LED (3) flashes red -> yellow once. The device is reset to default setting. 7 Technical data KNX RF KNX medium Commissioning mode Radio frequency Transmission capacity Transmitting range in free field Receiver category (Data according to EN 300220) RF1.R S-mode 868.0 ... 868.6 MHz max. 20 mW typ. 100 m 2 KNX TP (media coupler operation) KNX medium Commissioning mode 32591112 10867569 25.02.2020 TP256 S-mode 4 / 5 RF/TP media coupler/repeater Rated voltage KNX Current consumption KNX Repeater operation Rated voltage Degree of protection Protection class Ambient temperature Storage temperature Transport temperature Relative humidity Dimensions L×W×H 8 Accessories Flush-mounted power supply unit 250 mA Power supply for door communication 24 V DC 300 mA Gira Giersiepen GmbH & Co. KG Elektro-InstallationsSysteme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95 - 602-0 Fax +49(0)21 95 - 602-191 www.gira.de info@gira.de DC 21 ... 32 V SELV max. 5 mA DC 24 V SELV IP20 III -20 ... +55 °C -25 ... +45 °C -25 ... +70 °C 10 ... 100 % (no moisture condensation) 44x29x16 mm Order no. 2969 00 Order no. 1296 00 32591112 10867569 25.02.2020 5 / 5