User Guide for Edge-core models including: AS4630-54NPE, AS4630-54NPEM, Ethernet Switch
– 1 – E112020-MR-R01 150200002275A Ethernet Switch AS4630-54NPE | AS4630-54NPEM 1. AS4630-54NPE or AS4630-54NPEM Ethernet Switch 2. Rack mounting kit—2 brackets and 8 screws
Edgecore EPS203 AS4630-54NPE 36-Port 2.5GBASE-T 12-Port 10GBASE-T Bare Metal Switch with 4x 25G SFP28 Uplink Ports and 2x 100G QSFP28 Stacking Ports, ONIE - Part ID: 4630-54NPE-O-AC-F-US - Colfax Direct
File Info : application/pdf, 6 Pages, 1.35MB
DocumentDocumentQuick Start Guide Ethernet Switch AS4630-54NPE | AS4630-54NPEM Package Contents www.edge-core.com 1 2 3 4 5 1. AS4630-54NPE or AS4630-54NPEM Ethernet Switch 2. Rack mounting kit--2 brackets and 8 screws 3. 2 x Power cord 4. Console cable--RJ-45 to D-Sub 5. Documentation--Quick Start Guide (this document) and Safety and Regulatory Information 1 4 6 2 3 5 1. 1x USB port 2. 1 x Management port 3. 1 x Serial console port 4. System buttons/LEDs 5. 36 x RJ45 2.5G PoE ports System Buttons/LEDs Overview 8 9 10 7 6. 12 x RJ45 10G PoE Ports 7. 4 x SFP28 25G ports 8. 2 x QSFP28 40G/100G uplink or stacking ports 9. 3 x Fan trays 10. 2 x AC PSUs Port/FRU LEDs STK M/S button Reset button System LED: Green (OK), Amber (fault) PRI LED: Green (primary unit), Amber (secondary unit) PSU LEDs: Green (OK), Amber (fault) STK LEDs: Green (stacking ports active) FAN LED: Green (OK), Amber (fault) PoE LED: Green (OK), Amber (High PoE load) FRU Replacement RJ-45 Port LEDs: Green (link), Amber (link with PoE), Blinking (activity) SFP28 Port LEDs: White (25G), Green (10G), Blinking (activity) QSFP28 Port LEDs: White (100G), Green (40G link), Blinking (activity) PSU Status LED: Green (OK), Red (fault or fan failure) Fan Tray Status LED: Green (OK), Red (fault) PSU Replacement 1. Remove the power cord. 2. Press the release latch and remove the PSU. 3. Install replacement PSU with matching airflow direction. Fan Tray Replacement 1. Loosen the fan tray screw. 2. Remove fan tray from the chassis. 3. Install replacement fan with matching airflow direction. *150200002275A_R01* 1 E112020-MR-R01 150200002275A Installation Quick Start Guide Warning: For a safe and reliable installation, use only the accessories and screws provided with the device. Use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty. Avertissement: Pour une installation sûre et fiable, utilisez uniquement les accessoires et les vis fournies avec l'appareil. L'utilisation d'autres accessoires et vis pourrait endommager l'appareil. Les dommages causés par l'utilisation d'accessoires non approuvés ne sont pas couverts par la garantie. Caution: The device includes plug-in power supply (PSU) and fan tray modules that are installed into its chassis. Make sure all installed modules have a matching airflow direction (front-toback). Attention: Le appareil comprend des modules d'alimentation et de modules de ventilation installés dans son châssis. Assurez-vous que tous les modules installés ont une direction d'air adaptée (avant-arrière). Note: The device has the Open Network Install Environment (ONIE) software installer preloaded on the switch, but no switch software image. Information about compatible switch software can be found at www.edge-core.com. Note: Model name and approval markings are indicated on the product label located on the bottom of the device. 3. Lock the Rear-Post Brackets Use the included screws to lock the position of the rear-post brackets. Optional Slide-Rail Installation An optional slide-rail kit is available for rack installation. Follow the installation procedure provided with the kit. 2 Connect Power 1 Mount the Switch 1. Attach the Brackets Use the included screws to attach the front- and rear-post brackets. 2. Mount the Switch Mount the switch in the rack and secure it with rack screws. AC Power Install two AC PSUs and connect them to an AC power source. 3 Verify Switch Power Check the PSU LEDs The PSU1/PSU2 LEDs should be on green when operating normally. 4 Perform Initial System Boot 1. ONIE Installer Software If the network operating system (NOS) installer is located on a network server, first connect the RJ-45 Management (Mgmt) port to the network using 100-ohm Category 5, 5e or better twisted-pair cable. (Not required if the NOS installer is located on attached storage.) 2. Boot the Switch Wait for the ONIE software to locate and execute the NOS installer, and then wait for the installer to load the NOS software image. Subsequent switch boots will bypass ONIE and directly run the NOS software. Note: For switches with ONIE software pre-loaded, refer to the network operating system (NOS) installer and NOS documentation for details on software options and set up for ONIE. 2 Quick Start Guide 5 Make Network Connections 1. RJ-45 2.5G ports Connect 100-ohm Category 5e, 6a or 7 twisted-pair cable. Ports can support PoE connections up to 90 W. 2. RJ-45 10G ports Connect 100-ohm Category 6, 6a or 7 twisted-pair cable. Ports can support PoE connections up to 90 W. 3. SFP+/SFP28 slots First install SFP+/SFP28 transceivers and then connect fiber optic cabling to the transceiver ports. 6 (Optional) Make Stack Connections 1. Connect the top device Plug one end of a DAC cable in the bottom QSFP28 port of the top unit. 2. Connect the next device Plug the other end of the DAC cable into the top QSFP28 port of the next unit. 3. Repeat Repeat for each unit in the stack. 4. (Optional) Connect the top and bottom devices Plug one end of a DAC cable into the bottom QSFP28 port on the bottom unit and the other end into the top QSFP28 port on the top unit. 5. Reboot Reboot each switch in the stack to start the stack operations. Note: Stacking support is dependent on the switch software. For stacking support information, refer to the NOS software documentation. Hardware Specifications Switch Chassis Size (WxDxH) 438 x 474 x 44 mm (17.24 x 18.66 x 1.73 in) Weight 8.5 kg (18.74 lb), with two installed PSUs Temperature Operating: 0° C to 45° C (32° F to 113° F) Storage: -40° C to 70° C (-40° F to 158° F) Humidity Operating: 5% to 90% (non-condensing) 1 x 920 W Power Supply AC Input 100120 Vac, 50-60 Hz, 12 A (Not for China) 200240 Vac, 50-60 Hz, 6 A Power 920 W max. Consumption PoE Power Budget 620 W 2 x 920 W Power Supplies AC Input 100120 Vac, 50-60 Hz, 12 A (Not for China) 200240 Vac, 50-60 Hz, 6 A Power 1840 W max. Consumption PoE Power Budget 1540 W 1 x 1200 W Power Supply AC Input 100120 Vac, 50-60 Hz, 15 A (Not for China) 200240 Vac, 50-60 Hz, 8 A Power 1000 W max. (100120 Vac PSU) Consumption 1200 W max. (200240 Vac PSU) PoE Power Budget 700 W (100120 Vac PSU) 900 W (200240 Vac PSU) 2 x 1200 W Power Supplies AC Input 100120 Vac, 50-60 Hz, 15 A (Not for China) 200240 Vac, 50-60 Hz, 8 A Power 2000 W max. (100120 Vac PSUs) Consumption 2400 W max. (200240 Vac PSUs) PoE Power Budget 1700 W (100120 Vac PSUs) 2100 W (200240 Vac PSUs) Regulatory Compliances Emissions EN 55032:2015+AC:2016, Class A EN 61000-3-2:2014, Class A EN 61000-3-3:2013 FCC Class A VCCI Class A CCC GB 9254-2008, Class A BSMI Class A, CNS 13438 Immunity IEC 61000-4-2/3/4/5/6/8/11 Safety UL (UL 62368-1 & CSA C22.2 No. 62368-1) CB (IEC/EN 60950-1, IEC/EN 62368-1) CCC GB4943.1-2011 BSMI, CNS 14336-1 Taiwan RoHS CNS 15663 3 AS4630-54NPE | AS4630-54NPEM 1 1. AS4630-54NPE AS4630-54NPEM 2. --2 8 3. 2 1 4 6 2 3 5 1. 1 x USB 2. 1 x 3. 1 x 4. /LED 5. 36 x RJ45 2.5G PoE /LED 2 3 4 5 4. --RJ-45 D-Sub 5. -- 8 9 10 7 6. 12 x RJ45 10G PoE 7. 4 x SFP28 25G 8. 2 x QSFP28 40G/100G 9. 3 x 10. 2 x PSU /FRU LED STK M/S LED PRI LED PSU LED STK LED LED PoE LED PoE ) FRU RJ-45 LED : PoE) SFP28 LED : (25G) (10G) QSFP28 LED : (100G) (40G) PSU LED : PSU 1. 2. PSU 3. PSU 1. 2. 3. 4 Avertissement:Pour une installation sûre et fiable, utilisez uniquement les accessoires et les vis fournies avec l'appareil.L'utilisation d'autres accessoires et vis pourrait endommager l'appareil.Les dommages causés par l'utilisation d'accessoires non approuvés ne sont pas couverts par la garantie. 2 PSU Attention:Le appareil comprend des modules d'alimentation et de modules de ventilation installés dans son châssis.Assurezvous que tous les modules installés ont une direction d'air adaptée (avant-arrière ou arrière-arrière). (ONIE) www.edge-core.com 1 PSU 3 PSU LED PSU1/PSU2 LED 1. 4 1.ONIE (NOS) 100 5 5e RJ-45 (Mgmt) NOS 2. ONIE NOS NOS ONIE NOS ONIE ONIE NOS NOS 5 2. 1. RJ-45 2.5G 100-ohm 5e 6a 7 90W PoE 3. 2. RJ-45 10G 100-ohm 6 6a 7 90W PoE 3. SFP+/SFP28 SFP+/SFP28 5 6 1. DAC QSFP28 2. DAC QSFP28 3. 4. DAC QSFP28 QSFP28 5. NOS x x 438 x 474 x 44 mm (17.24 x 18.66 x 1.73 ) 8.5 kg (18.74 lb), PSU 0° C 45° C 32° F 113° F -40° C 70° C -40° F 158° F 5% 90% 1 x 920 W AC 100120 VAC, 50-60 Hz, 12 A (Not for China) 200240 VAC, 50-60 Hz, 6 A 920 PoE 620 2 x 920 W AC 100120 VAC, 50-60 Hz, 12 A ( ) 200240 VAC, 50-60 Hz, 6 A 1840 PoE 1540 1 x 1200 W AC 100120 VAC, 50-60 Hz, 15 A ( ) 200240 VAC, 50-60 Hz, 8 A 1000 (100120 VAC PSU) 1200 (200240 VAC PSU) PoE 700 (100120 VAC PSU) 900 (200240 VAC PSU) 2 x 1200 W AC 100120 VAC, 50-60 Hz, 15 A ( ) 200240 VAC, 50-60 Hz, 8 A 2000 (100120 VAC PSUs) 2400 (200240 VAC PSUs) PoE 1700 (100120 VAC PSUs) 2100 (200240 VAC PSUs) EN 55032:2015+AC:2016, Class A EN 61000-3-2:2014, Class A EN 61000-3-3:2013 FCC Class A VCCI Class A CCC GB 9254-2008, Class A BSMI Class A, CNS 13438 IEC 61000-4-2/3/4/5/6/8/11 UL (UL 62368-1 & CSA C22.2 No. 62368-1) CB (IEC/EN 60950-1, IEC/EN 62368-1) CCC GB4943.1-2011 BSMI, CNS 14336-1 RoHS CNS 15663 6