Instruction Manual for TANNOY models including: CVS 4, CVS 6, CVS 8, CVS 4 Ceiling Loudspeaker, Ceiling Loudspeaker, Loudspeaker
Tannoy Professional Products from Warehouse Sound Systems
File Info : application/pdf, 18 Pages, 616.86KB
DocumentDocumentINSTALLATION MANUAL CVS 4 CVS 6 CVS 8 CVS 4 TEMPLATE CUTOUT SIZE: 180mm CVS 6 TEMPLATE CUTOUT SIZE: 250mm CVS 8 TEMPLATE CUTOUT SIZE: 320mm CO N T E N T S 1 INTRODUCTION 2 UNPACKING 3 SAFETY NOTICES 4 PRODUCT FEATURE IDENTIFICATION 5 ACCESSORIES 6 INSTALLATION GUIDE 6 .1 MECHANICAL INSTALLATION GUIDE FOR SUSPENDED CEILINGS 6 .2 MECHANICAL INSTALLATION GUIDE FOR SHEET-ROCK CEILINGS 6 .3 MECHANICAL INSTALLATION INSTRUCTIONS FOR OPTIONAL PLASTER RING 7 WIRING AND SETTING UP 8 DIMENSIONS 8 .1 CVS 4 DIMENSIONS 8 .2 CVS 6 DIMENSIONS 8 .3 CVS 8 DIMENSIONS 9 TECHNICAL SPECIFICATIONS 1 0 PAINTING 1 1 WARRANTY 1 2 DECLARATION OF CONFORMITY 2 1. INTRODUCTION Thank you for purchasing this Tannoy Ceiling loudspeaker.This product range is suited for highlevel music and speech reinforcement applications requiring exceptional sonic quality with uncompromised reliability. 2. UNPACKING Every Tannoy product and accessory is carefully inspected before packing. After unpacking, please inspect your product to make sure no damage has occurred in transit. In the unlikely event of any damage, would you please notify your dealer immediately and retain your shipping carton, as your dealer may ask you to return the faulty unit to them for inspection. Each CVS loudspeaker is packed in pairs and provided with the following accessories as standard; C Ring, tile-bridge kit, grille, cut-out template, and paint mask. A plaster (mud) ring is also available as an optional extra. 3. SAFETY NOTICES Some regional construction codes require the use of a secondary method of securing loudspeakers in ceiling to provide security of a backup support. A secondary support line should be attached from the safety loop on the rear of the product to a source point on the ceiling. Please consult the relevant construction codes in your region. When using a power driver to install the product it is essential to use the correct torque level settings to avoid over tightening and damage to the ceiling material or clamps Recommended torque setting: 1.5Nm Tannoy will not be held responsible for any damages caused by the improper installation of these loudspeakers. Electrical Safety Notice: to comply with the standard UL1480 , metal-clad flexible conduit (BX) is required for connection to the terminal block for proper earth grounding. SAFETY NOTE: In order to comply with the relevant fire safety regulations (ie. BS 5839:1998), it is required that in the event of fire, that failure of the circuit to which the loudspeaker is connected does not occur before evacuation of the building is complete. Suitable measures include: a) use of terminal blocks (for connection to primary) with a melting point of not less than 650°C, for example constructed from ceramic materials; b) use of terminal blocks of a lower melting point but protected with thermal insulation; c) use of terminal blocks such that, on melting, an open-circuit or a short-circuit does not occur. 3 4 . PRODU CT FEAT U RE I DEN T I FI CAT I ON : CVS 4 Safety Tab Conduit/Cable Clamp Rotary Switch Mounting Wings CVS 6 Safety Tab Conduit/Cable Clamp CVS 8 Safety Tab Mounting Wings Rotary Switch Conduit/Cable Clamp Tuning Ports Tuning Ports Screws for mounting wings Screws for mounting wings Tuning Ports Rotary Switch Mounting Wings 4 Screws for mounting wings 5. ACCESSORIES: Standard Accessories C-Ring Grille Paint Mask Optional Accessories Plaster (Mud) Ring Tile bridge kit Note: A tile bridge kit must always be used when installing into suspended ceiling tiles Cut-out template 5 6 .1 M ECH AN I CAL I N STALLAT I ON GU I DE FOR SU SPEN DED CEI LI N GS 1 Remove the ceiling tile from its frame and place it on a flat surface. Mark the cut-out area on the ceiling tile by tracing around the template provided. 2 Cut out the hole in the ceiling tile using a circular saw or pad saw. 3 Place the C-ring and tile-bridge on top of the ceiling panel, aligning the C-ring over the hole, and screw the C-ring to the tile bridge using the fixings provided. 4 Slide the speaker assembly through the hole and turn the screws on the front of the speaker to extend the mounting wings. Tighten the screws until a firm grip is achieved. If using a power driver, Tannoy recommends a torque setting of 1.5Nm. DO NOT OVERTIGHTEN! 5 Slide the tile panel back into the suspended ceiling. The tile bridge ends will catch over the railings, supporting the weight of the speaker. 6 Connect a Secondary Support Line to safety tab. Some construction codes require use of this secondary support point, which should connect to a separate secure support point using a suitable support line. Consult construction codes in your region. Go to section 7 for instructions on wiring and set-up instructions. 6 6 .2 M ECH AN I CAL I N STALLAT I ON GU I DE FOR SH EET-ROCK (PLAST ER BOARD) CEI LI N GS 1 Mark the cut-out area on the ceiling by tracing around the template provided. 2 Cut out the hole in the ceiling using a circular saw or pad saw, then slide the C-ring into the ceiling, aligning it over the cut-out hole. 3 Go to section 7 for wiring and set-up instructions then return to point 4 below. 4 Slide the speaker assembly through the hole and turn the screws to extend the mounting wings. Tighten the screws until a firm grip is achieved. If using a power driver, Tannoy recommends a torque setting of 1.5Nm. DO NOT OVERTIGHTEN! 5 Connect a Secondary Support Line to safety tab. Some construction codes require use of this secondary support point, which should connect to a separate secure support point using a suitable support line. Consult construction codes in your region. 6 Insert grille by pushing it onto the speaker. 7 6 .3 M ECH AN I CAL I N STALLAT I ON I N ST RU CT I ON S FOR OPT I ONAL PLAST ER RI N G: An optional plaster (mud) ring bracket is available from Tannoy. This bracket is designed to be pre-installed into newly constructed, non-suspended ceilings. 1 Nail or screw the plaster ring to the joists. 2 Lay the speaker wiring to where the speaker will be fitted and complete the plastering work on the ceiling. 3 Cut out the hole in the ceiling using a circular saw or pad saw. 4 Go to section 7 for instructions on wiring then return to point 5 below. 5 Slide the speaker assembly through the hole and turn the screws to extend the mounting wings.Tighten the screws until a firm grip is achieved. If using a power driver, Tannoy recommends a torque setting of 1.5Nm. DO NOT OVERTIGHTEN! 6 Connect a Secondary Support Line to safety tab. Some construction codes require use of this secondary support point, which should connect to a separate secure support point using a suitable support line. Consult construction codes in your region. 7 Insert grille by pushing it onto the speaker. 8 7. WIRING AND SETTING UP: 1 Open the wiring cover at the back of the speaker can to access the Euro type connector plug and socket. 2 For connection to an amplifier, use pins 1 and 2: Pin 1 is positive Pin 2 is negative For connection to additional speakers in a distributed line, pins 3 and 4 are in parallel where: Pin 3 is negative Pin 4 is positive 3 Close the wiring cover and tighten both screws on the cable clamp. Use the rotary switch located on the front of the unit to select whether you wish to use the speaker in a low-impedance or distributed-line application. THE SPEAKER IS SUPPLIED IN LOW IMPEDANCE MODE. NEVER CONNECT THE SPEAKER TO A 70/100 VOLT AMPLIFIER WHILE IT IS SET FOR LOW IMPEDANCE. 4 The CVS 4 is fitted with a 30W transformer. When used in distributed-line systems, the transformer can be tapped at 30W, 15W and 7.5W, with an additional 3.75W tapping for 70.7V line systems. 5 The CVS 6 is fitted with a 60W transformer. When used in distributed-line systems, the transformer can be tapped at 60W, 30W, and 15W, with an additional 7.5W tapping for 70.7V line systems. 6 The CVS 8 is fitted with a 60W transformer. When used in distributed-line systems, the transformer can be tapped at 60W, 30W, and 15W, with an additional 7.5W tapping for 70.7V line systems. 9 8.1 CVS 4 DIMENSIONS: CVS 4 TEMPLATE CUTOUT SIZE: 180mm 202.5 [7.97"] 14.7 [0.58"] ø213.0 [8.39"] 214.9 [8.46"] ø174.8 [6.88"] 10 8.2 CVS 6 DIMENSIONS: CVS 6 TEMPLATE CUTOUT SIZE: 250mm 246.5 [9.70"] 15.9 [0.63"] ø279.6 [11.01"] 258.5 [10.18"] ø244.6 [9.63"] 11 8.3 CVS 8 DIMENSIONS: CVS 8 TEMPLATE CUTOUT SIZE: 320mm 251.0 [9.88"] 19.6 [0.77"] 355.6 [14.00"] 264.0 [10.39"] 315.2 [12.41"] 12 CVS4 TECHNICAL SPECIFICATIONS System CVS4 Frequency Response (-3dB) (1) 85Hz - 19kHz Frequency Range (-10dB) (1) 77Hz - 22kHz System Sensitivity (1W @1m) (2) 87dB (1W = 2.45V for 6 Ohms) Nominal Coverage Angle 90 degrees conical Coverage Angle (1kHz to 6kHz) 102 degrees Directivity Factor (Q) 5.6 averaged 1kHz to 6kHz Directivity Index (DI) 7.1 averaged 1kHz to 6kHz Rated Maximum SPL 103dB (average) 109dB (peak) Power Handling (3) Average Programme Peak 40W 80W 160W Recommended Amplifier Power 80W @ 6 Ohms Nominal Impedance 6 Ohms Transformer Taps (via front rotary switch) 70V 100V 30W / 15W / 7.5W / 3.75W / OFF & low impedance operation 30W / 15W / 7.5W / OFF & low impedance operation Distortion 1% Full Power 250Hz 1kHz 10kHz 2nd Harmonic 0.231% 0.229% 0.163% 3rd Harmonic 0.112% 0.253% 0.025% 10% Full Power 250Hz 1kHz 10kHz 2nd Harmonic 0.99% 0.816% 0.444% 3rd Harmonic 0.169% 0.323% 0.027% Crossover Point 2.7kHz Notes (1) Average over stated Bandwidth. Measured in an IEC baffle in an Anechoic Chamber (2) Unweighted Pink noise input, measured at 1m on axis" (3) Long term power handling capacity as defined in EIA - 426B test Transducers Low Frequency High Frequency Physical Enclosure Back can Baffle Grille Safety Features Clamping Design Back Can Options Cable Entry Options Connectors Safety Agency Ratings Hole Cutout Diameter Dimensions Bezel diameter Front of ceiling to rear of back can Front of ceiling to top of safety loop Net Weight (ea) Included Accessories Optional Accessories 100mm (4.00") Mineral Loaded 19mm (0.75") Zinc plated steel Reflex loaded UL 94V-0 rated ABS Steel, with weather resistant coating Safety ring located at rear of enclosure for load bearing safety bond Security toggle clamp Cable clamp & squeeze connector for conduit up to 22mm Removable locking connector with sctrew terminals with "loop through" facility UL-1480, UL-2043, CE 180mm 213.0mm (8.39") 202.5mm (7.97") 214.9mm (8.46") 2.60kg C Ring, tile bridge, paint mask, cutout template, grille Plaster (mud) ring 13 CVS6 TECHNICAL SPECIFICATIONS System CVS6 Frequency Response (-3dB) (1) 79Hz - 21kHz Frequency Range (-10dB) (1) 60Hz - 24kHz System Sensitivity (1W @1m) (2) 91dB (1W = 2.45V for 6 Ohms) Nominal Coverage Angle 90 degrees conical Coverage Angle (1kHz to 6kHz) 93 degrees Directivity Factor (Q) 7.7 averaged 1kHz to 6kHz Directivity Index (DI) 8 averaged 1kHz to 6kHz Rated Maximum SPL 109dB (average) 115dB (peak) Power Handling (3) Average Programme Peak 60W 120W 240W Recommended Amplifier Power 120W @ 6 Ohms Nominal Impedance 6 Ohms Transformer Taps (via front rotary switch) 70V 100V 60W / 30W / 15W / 7.5W / OFF & low impedance operation 60W / 30W / 15W / OFF & low impedance operation Distortion 1% Full Power 250Hz 1kHz 10kHz 2nd Harmonic 0.439% 0.396% 0.235% 3rd Harmonic 0.140% 0.458% 0.023% 10% Full Power 250Hz 1kHz 10kHz 2nd Harmonic 1.16% 1.014% 0.944% 3rd Harmonic 0.214% 0.685% 0.047% Crossover Point 2.5kHz Notes (1) Average over stated Bandwidth. Measured in an IEC baffle in an Anechoic Chamber (2) Unweighted Pink noise input, measured at 1m on axis (3) Long term power handling capacity as defined in EIA - 426B test Transducers Low Frequency High Frequency Physical Enclosure Back can Baffle Grille Safety Features Clamping Design Back Can Cable Entry Options Connectors Safety Agency Ratings Hole Cutout Diameter Dimensions Bezel diameter Front of ceiling to rear of back can Front of ceiling to top of safety loop Net Weight (ea) Included Accessories Optional Accessories 150mm (6.00") Mineral Loaded polypropylene ICTTM 19mm (0.75") Zinc plated steel Reflex loaded UL 94V-0 rated ABS Steel, with weather resistant coating Safety ring located at rear of enclosure for load bearing safety bond Security toggle clamp Cable clamp & squeeze connector for conduit up to 22mm Removable locking connector with sctrew terminals with "loop through" facility UL-1480, UL-2043, CE 250mm 279.5mm (11.01") 246.5mm (9.70") 258.5mm (10.18") 4.75kg C Ring, tile bridge, paint mask, cutout template, grille Plaster (mud) ring 14 CVS8 TECHNICAL SPECIFICATIONS System CVS8 Frequency Response (-3dB) (1) 79Hz - 21kHz Frequency Range (-10dB) (1) 60Hz - 24kHz System Sensitivity (1W @1m) (2) 93dB (1W = 2.45V for 6 Ohms) Nominal Coverage Angle 90 degrees conical Coverage Angle (1kHz to 6kHz) 84 degrees conical Directivity Factor (Q) 14.7 averaged 1kHz to 6kHz Directivity Index (DI) 11.7 averaged 1kHz to 6kHz Rated Maximum SPL 111dB (average) 117dB (peak) Power Handling (3) Average Programme Peak 60W 120W 240W Recommended Amplifier Power 120W @ 6 Ohms Nominal Impedance 6 Ohms Transformer Taps (via front rotary switch) 70V 100V 60W / 30W / 15W / 7.5W / OFF & low impedance operation 60W / 30W / 15W / OFF & low impedance operation Distortion 1% Full Power 250Hz 1kHz 10kHz 0.33% 0.15% 0.12% 0.25% 0.63% 0.03% 10% Full Power 250Hz 1kHz 10kHz 1.10% 0.55% 0.52% 0.25% 0.70% 0.03% Crossover Point 6kHz Notes (1) Average over stated Bandwidth. Measured in an IEC baffle in an Anechoic Chamber (2) Unweighted Pink noise input, measured at 1m on axis (3) Long term power handling capacity as defined in EIA - 426B test Transducers Low Frequency High Frequency Coaxial 200 mm (8.00") mineral loaded cone material 19mm (0.75") Physical Enclosure Back can Baffle Grille Safety Features Clamping Design Blind Mount (BM) Zinc plated steel Reflex loaded UL 94V-0 rated ABS Steel, with weather resistant coating Safety ring located at rear of enclosure for load bearing safety bond Security toggle clamp Back Can Cable Entry Options Cable clamp & squeeze connector for conduit up to 22mm Connectors Removable locking connector with sctrew terminals with "loop through" facility Safety Agency Ratings (pending) UL-1480, UL-2043, CE Hole Cutout Diameter 320mm (12.6") Dimensions Bezel diameter 355.6mm (14.00") Front of ceiling to rear of back can 251.0mm (9.88") Front of ceiling to top of safety loop 264.0mm (10.39") Template hole cutout size 250mm (9.84") Net Weight (ea) Included Accessories Optional Accessories 5.3kg (11.68lbs) C Ring, tile bridge, paint mask, cutout template, grille Plaster (mud) ring 15 1 0 . PAI N T I N G If desired, the grille and baffle panel may be painted to match the surrounding décor. Painting the baffle: Carefully mask off the driver assembly using the paint-mask provided to ensure that the paint does not come into contact with the cone and roll surround. Apply several thin coats of paint this will provide a better finish than one overly thick coat. Painting the grille: Carefully remove the acoustically transparent foam from the reverse side of the grille. Paint the grille and then replace the foam - several thin coats of paint will provide a better finish than one overly thick coat. Re-bond the foam to the grille over the entire area using a light spray-adhesive to avoid audible resonances. 11. WARRANTY No maintenance of the CVS loudspeaker is necessary. All Tannoy professional loudspeaker products are covered by a 5 year warranty from the date of manufacture subject to the absence of misuse, overload or accidental damage. Claims will not be considered if the serial number has been altered or removed. Work under warranty should only be carried out by a Tannoy Professional dealer or service agent. This warranty in no way affects your statutory rights. For further information please contact your dealer or distributor in your country. If you cannot locate your distributor please contact Customer Services, Tannoy Ltd at the address given below. Customer Services Tannoy Ltd. Rosehall Industrial Estate Coatbridge Strathclyde ML5 4TF Scotland Tel: 01236 420199 (National) +44 1236 420199 (International) Fax: 01236 428230 (National) +44 1236 428230 (International) E-mail: enquiries@tannoy.com DO NOT SHIP ANY PRODUCT TO TANNOY WITHOUT PREVIOUS AUTHORISATION Our policy commits us to incorporating improvements to our products through continuous research and development. Please confirm current specifications for critical applications with your supplier. 16 1 2 . DECLARAT I ON OF CON FORM I T Y: Details of the Apparatus: Model Numbers: Applicable Standards: Signed: The following apparatus is/are manufactured in China for Tannoy Ltd of Rosehall Industrial estate, Coatbridge, Scotland, ML5 4TF and conform(s) to the protection requirements of the European Electromagnetic Compatibility Standards and Directives relevant to Domestic Electrical Equipment. The apparatus is designed and constructed such that electromagnetic disturbances generated do not exceed levels allowing radio and telecommunications equipment and other apparatus to operate as intended, and, the apparatus has an adequate level of intrinsic immunity to electromagnetic disturbance to enable operation as specified and intended. This equipment conforms to the requirements of the EMC Directive 89/336/EEC, amended by 92/31/EEC and the requirements of the Low Voltage Directive 73/23/EEC, amended by 93/68/EEC. Tannoy Contractor Loudspeaker CVS 4 CVS 6 CVS 8 EN55103-1 1996 Emission EN55103-2 1996 Immunity Electrical Safety EN 60065: 1993 Position: Director of Engineering Tannoy Professional Date: 23/11/2011 For Tannoy Ltd 17 REVISION DATE: 03 March 2011 Tannoy has a policy of continuous improvement and this specification sheet provides the latest information at the time of printing. All specifications may be subject to further change. Please contact the Tannoy website for the latest information. ;HUUV`°+PYLJ[°°<2 ;*.0°96>°ZHSLZ ;*.((TLYPJHZZHSLZ ;HUUV`°4PKKSL°,HZ[ ;!°° °°° ;!°° ° ;!°°° °° ;!° ° ,!°LUX\PYPLZ'[HUUV`JVT ,!°PUMV'[JNYV\WPU[LYUH[PVUHSJVT ,!°PUMV'[JNYV\WHTLYPJHZJVT ,!°LUX\PYPLZ'[HUUV`JVT ;HUUV`°HKVW[Z°H°WVSPJ`°VM°JVU[PU\V\ZPTWYV]LTLU[HUK° WYVK\J[°ZWLJPMPJH[PVU° PZ°Z\IQLJ[°[V°JOHUNL 6481 0487