User Guide for BRIGGS STRATTON models including: 040806 Residential Standby Generators, 040806, Residential Standby Generators, Standby Generators, Generators

Briggs & Stratton Home Standby Generator PowerProtect 26kW Specification Sheet

Briggs & Stratton 040806 040806

RESIDENTIAL

18 apr 2024 — Frequency Regulation Steady State,. No Load to Full Load (%). /- 1.0. Air Filter Type. Dry. Low Oil Pressure Switch. Yes. Engine Oil Heater. Optional.5 pagine

Standby Generators

Standby Generators Standby Generators RESIDENTIAL SPECIFICATIONS kW 26 OVERVIEW Brand Briggs & Stratton Series Name Power Protect™ Model Name PP26 Model Number 040806 Rated AC Voltage (Volts) 120 / 240 Frequency (Hz) 60 Generator Breaker (Amps) 125 Operating Ambient Temperature (°C / °F)-28 - 40 / -20 - 104 Running Amperage,


File Info : application/pdf, 5 Pages, 349.90KB

PDF preview unavailable. Download the PDF instead.

BAS ES BS1306 PP26-40665 Spec(04-18-24)
26
kW

Standby Generators

RESIDENTIAL
Standby Generators
SPECIFICATIONS
OVERVIEW Brand Series Name Model Name Model Number Rated AC Voltage (Volts) Frequency (Hz) Generator Breaker (Amps) Operating Ambient Temperature (°C / °F) Running Amperage, Standby (LP / NG) (Amps) Running Power, Standby (LP / NG) (kW) Power Factor Programmable Exercise Cycle Engine Engine Brand/Manufacturer Model Type Aspiration Speed (RPM) Displacement (ci/cc) Compression Ratio Governor Type

Briggs & Stratton® Power ProtectTM PP26 040806 120 / 240 60 125
-28 - 40 / -20 - 104 108.3 / 100 261 / 24 1.0
16 sec (default) - 20 mins
Vanguard® M61
Naturally Aspirated 3600
61 / 993 9.7:1
Electronic

26
kW

Standby Generators
RESIDENTIAL STANDBY GENERATORS SPECIFICATIONS

Engine Bore & Stroke (mm / in) Cylinder Block Valve Arrangement Engine Cylinder Configuration Number of Cylinders Start Type Frequency Regulation Steady State, No Load to Full Load (%) Air Filter Type Low Oil Pressure Switch Engine Oil Heater Rated Temperature (°C / °F) Sound Rating2 Low Idle Mode Sound dB(A) Normal Operating Sound2 dB(A) Lubrication System Type Oil Capacity (oz / L) Oil Filter (Quantity / Type) Oil Brand Recommended Oil Electrical System Ignition System Battery Quantity Battery Voltage (VDC) Battery CCA (Amps) Battery Grouping Size Starter Motor Voltage (VDC) Fuel System Fuel Type Fuel Supply Line Inlet Recommended Fuel, Lower Heating Value Minimum (MJ/m3 / BTU/ft3) Fuel Supply Pressure (mbar / in H2O)

85.5 x 86.5 / 3.37 x 3.41 Aluminum with Cast Iron Sleeve
OHV V 2
Automatic +/- 1.0 Dry Yes Optional 25 / 77
63 65
Full Pressure 78 / 2.31
1 / Cartridge Schaeffer
5W30 Full Synthetic
Variable Timing 1 12
540 26 or 51
12
NG / LPV 3/4" NPT NG: 34.3 / 904 LPV: 87.1 / 2338 NG: 9-17 / 3.5-7 LPV: 28-34 / 11-14

26
kW

Standby Generators
RESIDENTIAL STANDBY GENERATORS SPECIFICATIONS

Fuel Consumption3 No Load, NG (BTU/hr) No Load, NG (ft3/hr) Half Load, NG (BTU/hr) Half Load, NG (ft3/hr) Full Load, NG (BTU/hr) Full Load, NG (ft3/hr) No Load, LP (BTU/hr) No Load, LP (ft3/hr) No Load, LP (gal/hr) Half Load, LP (BTU/hr) Half Load, LP (ft3/hr) Half Load, LP (gal/hr) Full Load, LP (BTU/hr) Full Load, LP (ft3/hr) Full Load, LP (gal/hr) Alternator Specifications Alternator Type Alternator Manufacturer Frequency (Hz) Phase Insulation Rating (Class) Designed Temperature Rise (°C) Bearing (Quantity / Type) Number of Poles Voltage Regulator Motor Starting Capability (kVA) Total Harmonic Distortion (THD), NL to FL (%) Controls/Instrumentation Controller Charger Starting LED Digital Display Alternator Frequency Real Time Clock Engine Hour Counter Engine Runtime Scheduler

122,000 122
206,000 206
323,000 323
123,000 49 1.40
235,000 94 2.60
427,000 171 4.70
Synchronous, Self-Excited, Rotating Field Briggs & Stratton 60 1 H 125 1 / Sealed 2
Brushed / Electronic 65.5 (35% Voltage Dip)
< 5
GC-1032 Stand Alone AMF or 2-wire
Yes Yes Yes Yes Yes

26
kW

Standby Generators
RESIDENTIAL STANDBY GENERATORS SPECIFICATIONS

Controls/Instrumentation Low Oil Pressure Shutdown High Temperature Shutdown Fault Code Display Other Features Battery Rack and Cables Fuel Solenoid Valve Integral Vibration Isolation Oil Drain Extension Operation and Installation Manual(s) Enclosure Enclosure Wind Speed Rating (mph) Accessories Maintenance Kit Oil Warmer Fuel Regulator Warmer Surge Protector UPS InfoHubTM Universal - Cellular Limited Warranty4 Warranty: Generator, Domestic & Canada (Parts / Labor / Travel) -- Years Warranty: Enclosure, Surface Rust and Corrosion (Parts / Labor / Travel) -- Years Warranty: Enclosure, Rust Through (Parts / Labor / Travel) -- Years Warranty: Non-Emergency (Parts / Labor / Travel) -- Years Certifications UL cUL CE Massachusetts Plumbers and Gasfitters Listing

Yes Yes Yes
Yes Yes Yes Yes Yes Aluminum 186
6872 6840 6845 6631 6581 6574
7 1 3 7yr or 1000 hr
Yes Yes No Yes

26
kW

Standby Generators
RESIDENTIAL STANDBY GENERATORS SPECIFICATIONS

Weights & Dimensions Assembled Dimensions (Length x Width x Height) (in / mm) Assembled Weight (lbs / kg) Packaged Dimensions (Length x Width x Height) (in / mm) Packaged Weight (lbs / kg)
Outline and Pad Layout Drawing

46.5 x 26.8 x 28.4 / 1181 x 681 x 721 540 / 245
48.8 x 30.5 x 50.5 / 1240 x 775 x 1283 625 / 285 80104089

46.5 in (1181 mm)

28.4 in (721 mm)
26.8 in (681 mm)

1 This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association) standard C22.2 No. 100-14 (motor and generators).
2 Per ISO 3744. Sound level measurement at other locations around generator may differ depending on installation, based on lowest microphone at 7m. Normal operation based on average household usage.
3 Fuel consumption rates are estimated based on normal operating conditions. Generator operation may be greatly affected by elevation and the cycling operation of multiple electrical appliances -- fuel flow rates may vary depending on these factors.
4 See operator's manual or energy.briggsandstratton.com for complete warranty details.

Briggs & Stratton has a policy of continuous product improvement and reserves the right to modify its specifications at any time and without prior notice. This standby generator is not for Prime Power applications. Please visit energy.briggsandstratton.com for the latest information. BS1306 - 04-18-24

BRIGGS & STRATTON POST OFFICE BOX 702 MILWAUKEE, WI 53201 USA
Copyright © 2024 Briggs & Stratton. All rights reserved.



References

Adobe PDF Library 17.0 Adobe InDesign 19.3 (Windows)