Instruction Manual for ebmpapst models including: R2E250-AV65-01 Fan Centrifugal, R2E250-AV65-01, Fan Centrifugal, Centrifugal

ebm papst


File Info : application/pdf, 9 Pages, 195.28KB

file 556dbec74b982
R2E250-AV65-01

Operating instructions

ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com
CONTENTS
1. SAFETY REGULATIONS AND NOTES 1.1 Levels of hazard warnings 1.2 Staff qualification 1.3 Basic safety rules 1.4 Electrical voltage 1.5 Safety and protective functions 1.6 Mechanical movement 1.7 Emission 1.8 Hot surface 1.9 Transport 1.10 Storage 1.11 Disposal
2. PROPER USE
3. TECHNICAL DATA 3.1 Product drawing 3.2 Nominal data 3.3 Technical features 3.4 Mounting data 3.5 Transport and storage conditions
4. CONNECTION AND START-UP 4.1 Connecting the mechanical system 4.2 Connecting the electrical system 4.3 Connection of the cables 4.4 Connection screen 4.5 Checking the connections 4.6 Switch on device 4.7 Switching off the device
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES 5.1 Cleaning 5.2 Safety test

1. SAFETY REGULATIONS AND NOTES

Please read these operating instructions carefully before starting to work

with the device. Observe the following warnings to prevent malfunctions

or physical damage to both property and people.

These operating instructions are to be regarded as part of this device.

If the device is sold or transferred, the operating instructions must

accompany it.

These operating instructions may be duplicated and forwarded for

information about potential dangers and their prevention.

1

1.1 Levels of hazard warnings

1

1

These operating instructions use the following hazard levels to indicate potentially hazardous situations and important safety regulations:

1

DANGER

1

Indicates an imminently hazardous situation which, if not

2

avoided, will result in death or serious injury. Compliance with

2

the measures is mandatory.

2

WARNING

2

Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Exercise extreme

2

caution while working.

2

CAUTION

2

Indicates a potentially hazardous situation which, if not avoided,

3

may result in minor or moderate injury or damage of property.

NOTE

4

A potentially harmful situation can occur and, if not avoided, can

4

lead to property damage.

5

1.2 Staff qualification

5

The device may only be transported, unpacked, installed, operated,

5

maintained and otherwise used by qualified, trained and authorised

5

technical staff.

Only authorised specialists are permitted to install the device, to carry

6

out a test run and to perform work on the electrical installation.

6

6

1.3 Basic safety rules

6

Any safety hazards stemming from the device must be re-evaluated once it is installed in the end device.

7

Observe the following when working on the unit:

8

; Do not make any modifications, additions or conversions to the

8

device without the approval of ebm-papst.

8

1.4 Electrical voltage

8

; Check the electrical equipment of the device at regular intervals, refer

to chapter 5.2 Safety test.

9

; Replace loose connections and defective cables immediately.

9

DANGER

Electrical load on the device

Risk of electric shock

 Stand on a rubber mat if you are working on an electrically charged device.

WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock
 Wait five minutes after disconnecting the voltage at all poles before opening the device.

Translation of the original operating instructions

Item no. 10773-5-9970 · Revision 82598 · Release 2014-05-08 · Page 1 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Downloaded from Arrow.com.

R2E250-AV65-01

Operating instructions

CAUTION In the event of failure, there is electric voltage at the rotor and impeller The rotor and impeller are base insulated.
 Do not touch the rotor and impeller once they are installed.
CAUTION The motor restarts automatically when operating voltage is applied, e.g. after a power failure. Danger of injury
 Keep out of the danger zone of the device.
 When working on the device, switch off the mains supply voltage and secure the latter from being switched on again.
 Wait until the device stops.
1.5 Safety and protective functions
DANGER Missing safety device and non-functioning safety device If there is no safety device, you could be seriously injured, for example if you reach into the running device or your hands are sucked into it.
 Operate the device only with a fixed and isolating safety protection and a fixed guard grille. The guard must withstand the kinetic energy of a fan blade detaching at maximum speed.
 The device is a built-in component. You, the owner/ operator, are responsible for providing adequate protection for the device.
 Shut down the device immediately if you detect a missing or ineffective protective feature.
1.6 Mechanical movement
DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured.
 Secure the device against accidental contact.
 Before working on the system/machine, wait until all parts have come to a standstill.
WARNING Rotating device Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured.
 Do not wear any loose clothing or jewellery while working on rotating parts.
 Protect long hair by wearing a cap.
1.7 Emission
WARNING Depending on the installation and operating conditions, a sound pressure level greater than 70 dB(A) may arise. Danger of noise-induced hearing loss
 Take appropriate technical safety measures.
 Protect operating personnel with appropriate safety equipment, e.g. hearing protection.
 Also observe the requirements of local agencies.

1.8 Hot surface
CAUTION High temperature at the motor housing Danger of burn injuries  Ensure that sufficient protection against accidental contact is
provided.
1.9 Transport
NOTE Transport of device  Transport the device in its original packaging only.  Secure the device so that it does not slip, e.g. by using a
clamping strap.
1.10 Storage ; Store the device, partially or fully assembled, in a dry and
weatherproof manner in the original packing in a clean environment. ; Protect the device from environmental impacts and dirt until the final
installation. ; We recommend storing the device for a maximum up to one year to
guarantee proper operation and longest possible service life. ; Even devices explicitly suited for outdoor use are to be stored as
described prior to being commissioned. ; Maintain the storage temperature, see
chapter 3.5 Transport and storage conditions.
1.11 Disposal
When disposing of the device, please comply with all relevant requirements and regulations applicable in your country.

Translation of the original operating instructions

Item no. 10773-5-9970 · Revision 82598 · Release 2014-05-08 · Page 2 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Downloaded from Arrow.com.

R2E250-AV65-01

Operating instructions

2. PROPER USE
The device is exclusively designed as a built-in device for moving air according to its technical data. Any other or secondary use is deemed improper and constitutes a misuse of the device. Installations on the customer's side must meet the mechanical, thermal and service life-related stresses that can occur.
Proper use also includes:  The device is to be used solely outside of the EU.  Moving air with a density of 1.2 kg/m³.  Using the device in accordance with the permitted ambient
temperature, see chapter 3.5 Transport and storage conditions and chapter 3.2 Nominal data.  Operating the device with all protective features in place.  Minding the operating instructions.
Improper use Using the device in the following ways is particularly prohibited and may cause hazards:  Operating the device with an imbalance, e.g. caused by dirt deposits
or icing.  Moving air that contains abrasive particles.  Moving highly corrosive air, e.g. salt spray mist. Exceptions are
devices that are intended for salt spray mist and protected accordingly.  Moving air that contains dust pollution, e.g. suctioning off saw dust.  Operating the device close to flammable materials or components.  Operating the device in an explosive atmosphere.  Using the device as a safety component or for taking on safety-
related functions.  Operation with completely or partially disassembled or modified
protective features.  In addition, all application options that are not listed under proper use.

Translation of the original operating instructions

Item no. 10773-5-9970 · Revision 82598 · Release 2014-05-08 · Page 3 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Downloaded from Arrow.com.

R2E250-AV65-01
3. TECHNICAL DATA 3.1 Product drawing

Operating instructions

All measures have the unit mm.

1

Connection line PVC, 4x brass lead tips crimped

2

Accessory part: Inlet nozzle 96359-2-4013, not included in the standard scope of delivery

3

Depth of screw max. 5 mm

Translation of the original operating instructions

Item no. 10773-5-9970 · Revision 82598 · Release 2014-05-08 · Page 4 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Downloaded from Arrow.com.

R2E250-AV65-01

Operating instructions

3.2 Nominal data

Motor

M2E068-DF

Phase

1~

1~

Nominal voltage / VAC 230

230

Frequency / Hz

50

60

Type of data definition fa

fa

Valid for approval /

-

-

standard

Speed / min-1

2550

2750

Power input / W

115

160

Current draw / A

0.51

0.71

Motor capacitor / µF

4

4

Capacitor voltage / VDB 400

400

Min. back pressure / Pa 0

0

Min. ambient temperature -25

-25

/ °C

Max. ambient

50

45

temperature

/ °C

ml = Max. load · me = Max. efficiency · fa = Running at free air cs = Customer specs · cu = Customer unit
Subject to alterations

3.3 Technical features

Mass Size Surface of rotor Material of impeller Number of blades Direction of rotation Type of protection Insulation class Humidity class Mounting position
Condensate discharge holes Operation mode Motor bearing Touch current acc. IEC 60990 (measuring network Fig. 4, TN system) Motor protection
Cable exit Protection class
Product conforming to standard Approval

2.5 kg 250 mm Coated in black PA plastic 11 Clockwise, seen on rotor IP 44 "B" F1-2 Shaft horizontal or rotor on bottom; rotor on top on request Rotor-side
S1 Ball bearing < 0.75 mA
Thermal overload protector (TOP) wired internally Variable I (if protective earth is connected by customer) EN 60335-1
CCC; EAC

For cyclic speed loads, note that the rotating parts of the device are designed for maximum one million load cycles. If you have specific questions, contact ebm-papst for support.

3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing ; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
You can obtain additional mounting data from the product drawing if necessary.

3.5 Transport and storage conditions

; Use the device in accordance with its protection type.

Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage)

+ 80 °C - 40 °C

Translation of the original operating instructions

Item no. 10773-5-9970 · Revision 82598 · Release 2014-05-08 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Downloaded from Arrow.com.

R2E250-AV65-01

Operating instructions

4. CONNECTION AND START-UP
4.1 Connecting the mechanical system
CAUTION Cutting and crushing hazard when removing the fan from the packaging
 Carefully hold the impeller to remove the device from its packaging. Make sure to avoid any shock.
 Wear safety shoes and cut-resistant safety gloves. ; Check the device for transport damage. Damaged devices must no
longer be installed. ; Install the undamaged device according to your application.
4.2 Connecting the electrical system
DANGER Electric voltage on the device Electric shock
 Always install a protective earth first.
 Check the protective earth.
DANGER Incorrect insulation Risk of fatal injury from electric shock
 Use only cables that meet the specified installation requirements for voltage, current, insulation material, load etc.
 Route cables such that they cannot be touched by any rotating parts.
CAUTION Electrical voltage The fan is a built-in component and features no electrically isolating switch.
 Only connect the fan to circuits that can be switched off with an all-pole separating switch.
 When working on the fan, you must switch off the installation/machine in which the fan is installed and secure it from being switched on again.
NOTE Water penetration into leads or wires Water enters at the cable end on the customers side and can damage the device.
 Make sure that the cable end is connected in a dry environment.
Connect the device only to circuits that can be switched off using an all-pole disconnecting switch.
4.2.1 Prerequisites
; Check whether the data on the type plate agree with the connection data and the data of the operating capacitor.
; Before connecting the device, ensure that the supply voltage matches the operating voltage of the device.
; Only use cables designed for current according to the type plate. For determining the cross-section, follow the basic principles in accordance with EN 61800-5-1. The protective earth must have a cross-section equal to or greater than the outer conductor crosssection. We recommend the use of 105°C cables. Ensure that the minimum

cable cross-section is at least AWG26/0.13 mm².
Earth wire contact resistance in accordance with EN 60335 Compliance with the impedance specifications in accordance with EN 60335 for the protective earth circuit must be verified in the end application. Depending on the installation situation, it may be necessary to install an additional protective earthing conductor via the additional protective earth connection point available on the device.
4.2.2 Voltage control
With open loop speed control using transformers or electronic voltage regulators (e.g. phase angle control), excessive current may occur. In addition, noises can occur with phase angle control depending on the mounting situation.
4.2.3 Frequency inverter
Please use a frequency converter only after consultation with ebm-papst.
Fit sinusoidal filters that work on all poles (live-live and liveearth) between the frequency inverter and the motor for operation with frequency inverters. Depending on how the device is installed, noises may occur. Heating of the motor due to use of a frequency converter must be checked in the application by the customer.
4.3 Connection of the cables
External leads are brought out of device. ; First connect the "PE" (protective earth) connection.  Connect the lines according to your application. When doing so,
observe chapter 4.4 Connection screen.

Translation of the original operating instructions

Item no. 10773-5-9970 · Revision 82598 · Release 2014-05-08 · Page 6 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Downloaded from Arrow.com.

R2E250-AV65-01 4.4 Connection screen

U1

blue

Z

brown

U2

black

PE

green/yellow

Operating instructions

Translation of the original operating instructions

Item no. 10773-5-9970 · Revision 82598 · Release 2014-05-08 · Page 7 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Downloaded from Arrow.com.

R2E250-AV65-01

Operating instructions

4.5 Checking the connections
; Make sure that the power is off (all phases). ; Secure it from being switched on again. ; Check the correct fit of the connection lines.
4.6 Switch on device
The device may only be switched on if it has been installed properly and in accordance with its intended use, including the required safety mechanisms and professional electrical connection. This also applies for devices which have already been equipped with plugs and terminals or similar connectors by the customer.
WARNING Hot motor housing Fire hazard
 Ensure that no combustible or flammable materials are located close to the fan.
; Inspect the device for visible external damage and the proper function of the protective features before switching it on.
; Check the air flow paths of the fan for foreign objects and remove any that are found.
; Apply the nominal voltage to the voltage supply.
4.7 Switching off the device
; Disconnect the device from the supply voltage at the main switch for the supply line.
; When disconnecting, be sure to disconnect the earth wire connection last.

5. MAINTENANCE, MALFUNCTIONS, POSSIBLE CAUSES AND REMEDIES

Do not perform any repairs on your device. Return the device to ebmpapst for repair or replacement.

WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock
 Wait five minutes after disconnecting the voltage at all poles before opening the device.

CAUTION Electrical load on the capacitor after device is switched off Electric shock, risk of injury
 Discharge the capacitors before working on the device.

CAUTION The motor restarts automatically when operating voltage is applied, e.g. after a power failure. Danger of injury
 Keep out of the danger zone of the device.
 When working on the device, switch off the mains supply voltage and secure the latter from being switched on again.
 Wait until the device stops.

If the device remains out of use for some time, e.g. when in storage, we recommend switching the device on for at least two hours to allow any condensate to evaporate and to move the bearings.

Malfunction/error Impeller running roughly
Motor does not turn

Possible cause Imbalance in rotating parts
Mechanical blockage
Mains supply voltage faulty Faulty connection Thermal overload protector responded

Possible remedy Clean the device; if imbalance is still evident after cleaning, replace the device. If you have attached any weight clips during cleaning, make sure to remove them afterwards. Switch off, deenergise, and remove mechanical blockage. Check mains supply voltage, restore power supply. De-energise, correct connection, see connection diagram. Allow motor to cool off, locate and rectify cause of error, if necessary cancel restart lock-out

Translation of the original operating instructions

Item no. 10773-5-9970 · Revision 82598 · Release 2014-05-08 · Page 8 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com Downloaded from Arrow.com.

R2E250-AV65-01

Operating instructions

Overtemperature of motor

Unacceptable operating point Ambient temperature too high Insufficient cooling

Check operating point
Lower ambient temperature if possible Improve cooling

If you have any other problems, contact ebm-papst.

5.1 Cleaning

NOTE Damage to the device during cleaning. Malfunction possible
 Do not clean the device using a water jet or high-pressure washer.
 Do not use any cleaners containing acids, bases or solvents.
 Do not use any pointed or sharp-edged objects to clean.

5.2 Safety test

What has to How to test? Frequency

be tested?

Check the

Visual inspection At least every

protective

6 months

casing against

accidental

contact for

damage and to

ensure that it is

intact

Check the

Visual inspection At least every

device for

6 months

damage to

blades and

housing

Mounting the Visual inspection At least every

connection lines

6 months

Mounting of Visual inspection At least every

protective

6 months

earth connection

Check the

Visual inspection At least every

insulation of

6 months

the wires for

damage

Impeller for

Visual inspection At least every

wear/deposits/

6 months

corrosion and

damage

Condensate Visual inspection At least every

discharge

6 months

holes for

clogging, as

necessary

Which measure? Repair or replacement of the device
Replacement of the device
Fasten Fasten
Replace wires
Clean or replace impeller
Open bore holes

Translation of the original operating instructions