INSTALLATION MANUAL---Important considerations
When compared with other refrigerants, R32 is more environmentally friendly. Please use this product as instructed. This refrigerant is flammable and may combust under certain conditions, however when this product is used as directed these risks are significantly reduced. Always consult with a trained professional when maintaining or repairing an air conditioner.
Warning
- Please read the manual before installing, using, or conducting maintenance.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- Be aware that refrigerants may not contain an odor.
- Do not pierce or burn the appliance.
- The appliance shall be stored in a room without continuously operating sources (for example: open flames ?, an operating ignition gas appliance or an operating electric heater).
- Please contact the nearest after-sale service center when maintenance is necessary. At the time of maintenance, the maintenance personnel must strictly comply with the Operation Manual provided by the corresponding manufacturer and any non-professional is prohibited to maintain the air conditioner.
- It is necessary to comply with the provisions of gas-related federal, state, and local laws and regulations.
- It is necessary to clear away the refrigerant in the system when maintaining or an air conditioner by a trained professional.
Warning: flammable & Dangerous
Read the user manual
Read the installation manual
Read the service manual
Important Considerations
The air conditioner you buy must be installed by professional personnel and the "Installation manual” is used only for the professional installation personnel! The installation specifications should be subject to TCL's after-sale service regulations.
- When filling the flammable refrigerant, please use caution to avoid serious injury.
- A leak test must be done after the installation is completed.
- It is a must to perform the safety inspection before maintaining or repairing an air conditioner using flammable refrigerant in order to ensure that the fire risk is reduced to a minimum.
- Requirements for the total weight of filled refrigerant and the area of a room to be equipped with an air conditioner are shown in the following Tables GG.1 and GG.2.
The air conditioner unit needs to sit on a flat even surface.
The maximum charge and the required minimum floor area
Formulas for calculating maximum charge (mmax) and minimum floor area (Amin) are provided:
m1 = (4 m³) x LFL, m2 = (26 m³)) x LFL, m3 = (130 m³ )x LFL
Where LFL is the lower flammable limit in kg/m³. R290 LFL is 0.038 kg/m³, R32 LFL is 0.038 kg/m³.
For appliances with a charge amount m1 < M = m2:
The maximum charge in a room shall be in accordance with the following: mmax = 2.5 x (LFL)(5/4) x ho x (A)1/2
The required minimum floor area Amin to install an appliance with refrigerant charge M (kg) shall be in accordance with following: Amin = (M / (2.5 x (LFL)(5/4) x ho))2
Where:
- mmax is the allowable maximum charge in a room, in kg;
- M is the refrigerant charge amount in appliance, in kg;
- Amin is the required minimum room area, in m²;
- A is the room area, in m²;
- LFL is the lower flammable limit, in kg/m³;
- ho is the installation height of the appliance, in meters for calculating mmax or Amin (1.8 m for wall mounted).
Table GG.1 - Maximum charge (kg)
Category | LFL (kg/m³) | ho (m) | Floor area (m²) | ||||||
---|---|---|---|---|---|---|---|---|---|
4 | 7 | 10 | 15 | 20 | 30 | 50 | |||
R32 | 0.306 | 0.6 | 0.68 | 0.9 | 1.08 | 0.32 | 1.53 | 1.87 | 2.41 |
1 | 1.14 | 1.51 | 1.8 | 2.2 | 2.54 | 3.12 | 4.02 | ||
1.8 | 2.05 | 2.71 | 3.24 | 3.97 | 4.58 | 5.61 | 7.254 | ||
2.2 | 2.5 | 3.31 | 3.96 | 4.85 | 5.6 | 6.86 | 8.85 |
Table GG.2 - Minimum room area (m²)
Category | LFL (kg/m³) | ho (m) | Charge amount (M) (kg) | ||||||
---|---|---|---|---|---|---|---|---|---|
1.224kg | 1.836kg | 2.448kg | 3.672kg | 4.896kg | 6.12kg | 7.956kg | |||
R32 | 0.306 | 0.6 | 29 | 51 | 116 | 206 | 321 | 543 | |
1 | 10 | 19 | 42 | 74 | 116 | 196 | |||
1.8 | 3 | 6 | 13 | 23 | 36 | 60 | |||
2.2 | 2 | 4 | 9 | 15 | 24 | 40 |
Installation Safety Principles
1. Site Safety
Open Flames Prohibited
Ventilation Necessary
2. Operation Safety
Mind Static Electricity
Must wear protective clothing and anti-static gloves
Don't use mobile phone
3. Installation Safety
- Refrigerant Leak Detector
- Appropriate Installation Location
The left picture is the schematic diagram of a refrigerant leak detector.
Please note that:
- The installation site should be in a well-ventilated area.
- The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding, smoking, drying oven or any other heat source higher than 548 °C which easily produces open fire.
- When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-static clothing and/or gloves.
- Installation or maintenance location should not be surrounded by obstacles or close to any heat source, flammable, and/or explosive areas or objects.
- If the product suffers refrigerant leak during the installation, all personnel should go out till the refrigerant leaks completely for 15 minutes. If the product is damaged, a professional must carry such damages product back to the maintenance station. It is prohibited to weld the refrigerant pipe or conduct other operations on the contaminated site.
- The air conditioner unit needs to sit on a flat even surface.
- It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables directly under the lines on two sides of the indoor unit.
- Any ventilation openings of unit should be free from obstructions.
Related Documents
![]() |
TCL Q-Series Window Air Conditioner User Manual and Installation Guide Comprehensive user manual for the TCL Q-Series Window Air Conditioner, covering setup, installation, operation, maintenance, warranty, and troubleshooting. Includes app control features and safety guidelines. |
![]() |
TCL R-Series Portable Air Conditioner User Manual and Installation Guide Comprehensive guide for the TCL R-Series Portable Air Conditioner, covering installation, operation, troubleshooting, and warranty information. Learn how to set up and use your portable AC for optimal comfort. |
![]() |
TCL Q-Series Window Air Conditioner User Manual Comprehensive user manual for the TCL Q-Series Window Air Conditioner (Model H8W25WQ), covering setup, installation, operation, maintenance, troubleshooting, and warranty information. Includes safety guidelines and control features. |
![]() |
TCL Smart Wifi Ceiling Mounted Multi Cassette Air Conditioner User and Installation Manual Comprehensive user and installation manual for TCL Smart Wifi Controlled Ceiling Mounted Multi Cassette Air Conditioners, covering models like iQool-C2MS12K12K and iQool-C3MS9K9K9K. Includes safety, operation, Wi-Fi setup, installation, maintenance, and troubleshooting. |
![]() |
TCL Split Type Air Conditioner Instruction Manual This instruction manual provides comprehensive guidance on the operation, installation, maintenance, and troubleshooting of TCL Split Type Air Conditioners, specifically for multi-split systems. It covers safety precautions, remote controller functions, operating modes, installation procedures, and error codes. |
![]() |
TCL Portable Air Conditioner Owner's Manual This owner's manual provides essential safety instructions and operating guidelines for TCL portable air conditioners. Learn how to safely install, use, and maintain your appliance. |
![]() |
TCL 15K-24K Window AC: Quick Start Guide & Installation Manual Get started with your TCL 15K-24K Window Air Conditioner. This guide provides essential information on installation, operation, troubleshooting, and warranty for TCL window AC units. |
![]() |
TCL H5P44W Portable Air Conditioner Energy Guide - Efficiency and Cost Detailed EnergyGuide label for the TCL H5P44W portable air conditioner, providing estimated yearly energy cost, cost range of similar models, and combined energy efficiency ratio. Includes specifications and usage notes. |