User Manual for solaV models including: LS 1012 EPD LS-EPD-Series PWM Charge Controller, LS 1012, EPD LS-EPD-Series PWM Charge Controller, PWM Charge Controller

USER

User

PDF USER - solarv.de

3 4 www.solarv.de Copyright © 2022 SolarV GmbH All rights reserved

USER - solarv.de

Operating manual: EPEVER PWM Charge Controller LS EPD

EPEVER PWM Charge Controller LS1024EPD|10A, 12/24VDC Auto, Waterproof, 27,95 €


File Info : application/pdf, 4 Pages, 380.27KB

PDF preview unavailable. Download the PDF instead.

EPEVER PWM-Charge-Controller LS-EPD-EN
USER MANUAL
LS-EPD-Series PWM Charge Controller

www.solarv.de

1

Modell: LS 1012 EPD LS 1024 EPD LS 2024 EPD
Copyright2© 2022 SolarV GmbH All rights reserved

LS-EPD Series Solar Charge Controller
1. General Information
LS-EPD series solar charge controller adopts the most advanced digital technique and operates fully automatically. It is ideal for extreme environments with corrosion, dust, water etc and has various unique functions  Electronic protection: Over charging, over discharging, overload, short circuit and reverse
protection of solar module  High efficient Series PWM charging, increase the battery lifetime and improve the solar
system performance  Widely used, automatically recognize day/night  Battery LED indicate battery status  Industrial design, wide application range  Digital tube menu, only one key solve all setting simply  Intelligent timer function with 113 hours option  IP67 protection
2. Features and Mounting

1 2 3 4 5 6 7 8 9 10

 Charging Status LED indicator



 Battery Status LED indicator



 Temperature Sensor



 Solar Module Terminals



 Battery Terminals



Figure1 Mounting
Load Terminals Digital tube Key Aluminum housing Mounting hole 5

1
www.solarv.de

 Mounting
1) Connect components to the charge controller in the sequence as shown above picture and pay much attention to the "+" and "-". Always power the battery firstly.
2) After power the battery, check the battery indicator on the controller, it will be green. If it's not green, please refer to chapter 4.
3) The battery fuse should be installed as close to battery as possible. The suggested distance is within 150mm.
3. Indicators Description and Operation

1) Indicator Status Description

Charging Status LED indicator
Battery Status LED indicator
Radix Point of Digital tube
(Load indicator)

Green Green Green Green Orange Red Red Red Red

On Solid Fast Flashing
On Solid Slowly Flashing
On Solid On Solid On Solid Slowly Flashing Fast Flashing

Normal Over voltage
Normal Full
Under voltage Over discharged
Load ON Over Load Short Circuit

2) Operation Digital tube Key

The digital tube display the load work mode, please refer to the correspondence table of Load Work Mode & LED digital tube value. Pressing the key to configure the parameter, please refer to the below configuration method:

1) After Powering on, disconnect the PV or connect the PV(Voltage<5V) , the light of the digital tube point go on; Connect the PV(Voltage>6V) ,the light of the digital tube point go off.
2)The key can be used to operate switching on/off the load (Manual control) or clearing the faults
3) Keeping pressing the button over 5S, It will go to the parameter in browsing mode which can cycle through the parameter item by clicking the button ,after the light of the digital tube point going on.
4) After the digital tube displaying the value what you want to configure, releasing the key and waiting 15S, Digital Tube stop flashing, then the configuration is successful.

2
Copyright © 2022 SolarV GmbH All rights reserved

 Load mode

 Manual ControlControl the load via the button.

Light ON/OFF

Light ON + Timer

Note: In the mode of Light ON/OFF and Light ON/Timer, the Load is turned on after

10Min. delay.

 Test Mode (Default)Test Mode is as same as Light Control Mode but no delay.  The correspondence table of Load Work Mode & LED digital tube value

Value

Working mode

Value

Working mode

Light ON/OFF

Light ON + 8 hours

Light ON + 1 hours

Light ON + 9 hours

Light ON + 2hours

Light ON + 10 hours

Light ON + 3hours

Light ON + 11 hours

Light ON + 4 hours

Light ON + 12 hours

Light ON + 5 hours

Light ON + 13 hours

Light ON + 6 hours

Manual Control

Light ON + 7 hours

Test Mode

4. Troubleshooting

Faults

Possible reasons

Charging LED indicator off during daytime when sunshine falls on PV modules properly

PV array disconnection

Troubleshooting
Check that PV and battery wire connections are correct and tight

Charging Status LED indicator fast flashing

Battery voltage higher than over voltage disconnect voltage

1. Disconnect the solar array and measure the battery voltage whether is too high; 2. Change the controller; 3. Change the battery

Battery LED indicators red color and loads not working

Battery over discharged

The controller cut off the output automatically. LED indicator will return to green automatically when fully

The radix point of digital tube fast flashing and load not working

Short circuit

Clear short circuit. It is reactivated after delayed 10 seconds for the first time, If over 1 timepress the key to clear error
and the controller will resume to work after 3s or restart the controller

The radix point of digital tube slowly flashing and load not working

Over load

Please reduce the number of electric equipments. When load power reaches 1.25-1.5 times, 1.5-2 times and 2 times more than nominal value, controller will automatically close loads in 60 seconds, 5 seconds and 1 second, respectively. Please press the key to clear error and the controller will resume to work after 3s or restart the controller

6. Technical Specifications

Item

LS1012EPD

LS1024EPD

LS2024EPD

Nominal system voltage

12VDC

12/24VDC Auto

12/24VDC Auto

Max. PV input voltage

30V

50V

50V

Rated current

10A

10A

20A

Equalize Voltage

14.8V(12V);29.6V(24V)

Boost Voltage

14.4V(12V);28.8V(24V)

Float Voltage

13.7V(12V);27.4V(24V)

Low Voltage Reconnect Voltage

12.6V(12V);25.2V(24V)

Low Voltage Disconnect Voltage
Self-consumption

11.2V(12V);22.4V(24V) 12V4.58mA24V6.01mA

Temperature compensation coefficient
Working temperature

-5mV//2V25 -35+55

Enclosure

IP67

Overall dimension

108.5mm×75mm×25.6mm

Mounting dimension Mounting hole size
Power cable

100.5mm

5

PV/BAT/LOAD:4.0mm2

PV/BAT/LOAD:6.0mm2

Net weight

408g

410g

435g

3
www.solarv.de

4
Copyright © 2022 SolarV GmbH All rights reserved

Copyright © 2022 SolarV GmbH All rights reserved

3

4



References