Instruction Manual for narda models including: 3310 SignalShark Handheld Spectrum, 3310, SignalShark Handheld Spectrum, Handheld Spectrum, Spectrum
File Info : application/pdf, 70 Pages, 24.49MB
DocumentDocumentSignalShark - User Interface Manual SignalShark > User Interface Manual 2022-06 © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 0 SignalShark - User Interface Manual Contents > SignalShark 3310 Handheld Device Overview > SignalShark 3320 Remote Unit Device Overview > Screen Layout Brief introduction to the most important GUI components > Basic Operation The basic operating steps © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 1 SignalShark - User Interface Manual SignalShark 3310 Handheld Device Overview Handheld Unit © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 2 SignalShark - User Interface Manual SignalShark 3310 Device Overview Rugged design for mobile use, even in harsh environments MIL-PRF-28800F class 2 > 2 x smart technology lithium-ion internal and external rechargeable battery packs > Hot-swappable for interruption-free long-term measurements > Batteries commercially available, Type: RRC2057, Li-ion, 48 Wh > Internal and external charging > Car-charger available > Operating time: approx. 3 hours © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 3 SignalShark - User Interface Manual SignalShark 3310 Device Overview Microphone to record voice comments © Narda Safety Test Solutions GmbH Scroll wheel and keyboard for > Navigating > Changing settings > Entering values > Confirming/deleting inputs Illuminated keyboard for working in dark environments LEDs to indicate the operating status separately for batteries as well as for the operating status of the device. Built-in help function, Stealth mode, keyboard and touch lock www.narda-sts.com Slide 4 SignalShark - User Interface Manual SignalShark 3310 Device Overview Built-in weather sealed loudspeaker gives clear, loud sound reproduction, even in noisy environments 10.4" resistive touch screen > Intuitive operation, even when wearing gloves > Shielded for extreme EMC immunity © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 5 SignalShark - User Interface Manual SignalShark 3320 Device Overview Connector Panel 1) USB 3.0 connection 2) 3.5mm headphone jack 3) External GNSS SMA(f) input, 50 Ohm > DC voltage for active antenna is supplied 4) Micro SD card slot (microSDXC) 5) PPS/trigger SMA(f) input 6) 1 GigE connector for remote control and I/Q streaming 7) DC input / charging jack © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 6 SignalShark - User Interface Manual SignalShark 3320 Device Overview Connector Panel 8) 3 x RF SMA(f) input 9) RF N(f) input for connecting the antenna 10) 12-pin jack for connecting the antenna control cable 11) 10 MHz Ref SMA(f) input © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 7 SignalShark - User Interface Manual SignalShark 3320 Device Overview Bottom View 1) USB 2.0 connection 2) Display Port Note: Display Port and USB connector can be used to connect an external touch screen. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 8 SignalShark - User Interface Manual SignalShark 3310 Device Overview Battery Operation > Battery Operating Status The operating status of the batteries is separately displayed for each battery with 2 LEDs in the keyboard area Indicator Significance LED lights up red Battery is charging. LED lights up green Charging is completed or charger/power supply is still connected to the charging jack of the unit. LED is off No battery is inserted or no charging/power supply is connected. > Charging the Batteries > Charging times for a complete charging cycle are as follows: > When both batteries are charged in the device: approx. 4.2 hours (nom.) > When charged in external charger: approx. 3 hours (nom.) © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 9 SignalShark - User Interface Manual SignalShark 3310 Device Overview Starting Up > Switching the Device on and off > Push the power key for about 2 seconds and release it again to switch the device on. > Push the power key for about 3 seconds and release it again to switch the device off. > Pressing the power button for about 10 seconds is basically like cutting the power to the system. WARNING: This can lead to loss of data! > Device Operating Status LED > LED lights up red: Device is in initialization phase or an error occurred > LED lights up green: Device is operational > LED flashes green: Device is in stealth mode > © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 10 SignalShark - User Interface Manual SignalShark 3310 Device Overview Special Hard Keys > Stealth/Touch > A short press on the Stealth/Touch button will start the stealth mode. Stealth mode allows you to quickly deactivate/reactivate the display and audio playback. The device will switch off completely after 10 minutes in stealth mode to save battery power. > A long press on the Stealth/Touch button will toggle the touch lock. > Mouse Emulation In touch lock you can operate the device via a mouse emulation. The mouse pointer can be controlled by the arrow keys. A short press on the OK button will emulate a mouse left click. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 11 SignalShark - User Interface Manual SignalShark 3310 Device Overview Special Hard Keys > Integrated Help / Preset > A short press on the Help/Preset button opens the integrated help documentation. > It can take some seconds until the Help has started up because it is displayed in a separate web browser. > A long press on the Help/Preset button will load and apply the default task. Warning: All existing Tasks will be removed when applying the default setup! © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 12 SignalShark - User Interface Manual SignalShark 3310 Device Overview Special Hard Keys > Run/Single Run > A short press on the Run/Single Run button will stop or hold the current measurement acquisition depending on the actual "Stop Mode" setting. > Button Bar Config Stop Mode Hold/Stop > Stop: Display update and measurement acquisition is stopped. > Hold: Display update is on hold, but measurement acquisition still runs in the background (trace data will be collected). Note: Spectrogram marker can only be used, if measurement is on hold or stopped. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 13 SignalShark - User Interface Manual SignalShark 3310 Device Overview Special Hard Keys > Run/Single Run > A long press on the Run/Single Run button will start a single run measurement. > In single run, the device will run a special amount of measurement cycles ("Scan Count") and then stop/hold the measurement acquisition. Note: Single Run can be used to measure a defined number of measurement cycles or over a specified period of time (e.g. for Spectrum AVG trace, RMS channel power). © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 14 SignalShark - User Interface Manual SignalShark 3310 Device Overview Special Hard Keys > Volume/Mute > A short press on the Volume/Mute button opens the volume settings menu. > A long press on the Volume/Mute button switches system sound on/off. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 15 SignalShark - User Interface Manual SignalShark 3320 Remote Unit Device Overview Remote Unit © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 16 SignalShark - User Interface Manual SignalShark 3320 Device Overview Front Panel 1) ON/OFF button 2) Device Status LED > Green: Device is operational > Red: Device is in initialization phase or an error occurred 3) Stereo jack, 3.5 mm headphone jack 4) Ethernet Connection Status LED > LED LINK lights up orange: 100 Mbit > LED LINK lights up green: 1 Gbit > LED ACT lights green: Traffic 12 3 4 Note: The device starts automatically when connected to the power supply. The device can also be started via WakeOnLan (WOL). © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 17 SignalShark - User Interface Manual SignalShark 3320 Device Overview Front Panel 5) Product description on the top of the device > QR codes including P/N, S/N, Mac address, etc. 6) Display port 7) USB 2.0 connection 5 6 7 Note: Display Port and USB connector can be used to connect an external touch screen © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 18 SignalShark - User Interface Manual SignalShark 3320 Device Overview Back Panel 1) 3 x RF SMA(f) input 2) RF N(f) input 3) 12-pin jack for connecting the antenna control cable 4) 10 MHz Ref SMA(f) input, 600 Ohm 1 1 1 2 3 4 © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 19 SignalShark - User Interface Manual SignalShark 3320 Device Overview Back Panel 5) USB 3.0 connection 6) External GNSS SMA(f) input, 50 Ohm > DC voltage for active antenna is supplied 7) Product description including P/N, S/N, Mac address 8) Micro SD card slot (microSDXC) 9) PPS / trigger SMA(f) input, 100 kOhm 10) 1 GigE connector > For remote control, I/Q streaming, and network connection, e.g. the Internet access for Win10 11) DC input 11 10 9 8 © Narda Safety Test Solutions GmbH www.narda-sts.com 76 5 Slide 20 SignalShark - User Interface Manual SignalShark 3320 Device Overview Starting Up > Switching the Device on and off > Push the power key for about 2 seconds and release it again to switch the device on. > Push the power key for about 3 seconds and release it again to switch the device off. > Pressing the power button for about 10 seconds is basically like cutting the power to the system. WARNING: This can lead to loss of data! > Device Operating Status LED > LED lights up red: Device is in initialization phase or an error occurred > LED lights up green: Device is operational © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 21 SignalShark - User Interface Manual Screen Layout Brief introduction to the most important GUI components © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 22 SignalShark - User Interface Manual Screen Layout 1) System Information Area 1 > Briefly displays the most important system information like > Date/Time > Battery status > GNSS status > Mute / Touch lock © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 23 SignalShark - User Interface Manual Basic Operation 1) System Information Area 1 > A tap on the dropdown icon opens the system information menu © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 24 SignalShark - User Interface Manual Basic Operation System Information Menu > The system information menu provides status information about several system parameters. Note: This menu is only for displaying information! Please use the System Settings menu to change system settings. > You can leave the menu by > Pressing the Esc. hard key or > A short tap on the Button Bar Header © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 25 SignalShark - User Interface Manual Screen Layout 2) Toolbar > Contains tool buttons that provide quick and easy access to the most important device functions General Settings Tap to open the general settings menu Data Logger Tap to manage stored data sets, demodulation records and screenshots. Save Measurement Tap to save the current measurement. Screenshot Tap to store a screenshot from the current display. Undo/Redo Tap the dropdown icon to open the action history. © Narda Safety Test Solutions GmbH www.narda-sts.com 2 Slide 26 SignalShark - User Interface Manual Screen Layout 2) Toolbar > Contains tool buttons that provide quick and easy access to the most important device functions Run Tap to start or stop/hold a measurement. SRun Tap to start a single measurement run according to the Scan Count parameter. Marker Tap to open the Marker menu. Scripting (if installed) Tap to start NardaScriptLauncher Additional Functions Menu Tap to open a dropdown window with additional functions like: Volume/Mute, Configure Views, Preset or Help © Narda Safety Test Solutions GmbH www.narda-sts.com 2 Slide 27 Tasks and Views The goal of the design and GUI layout of SignalShark was to support a fast and easy way to do measurements in real live applications. > Often an application consists of several measurements like finding a signal in the spectrum, measuring its level and locate it. > On many sites, several kinds of signals in different frequency bands have to be analyzed. That's why SignalShark replaces the conventional concept of measurement modes by the Tasks and Views concept. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 28 Tasks > Tasks are represented by a tab on the screen, like a web site within a web browser. > Tasks encapsulate all measurement parameters and the underlying measurement acquisition. > Within a task, all measurements are performed at the same time. Note: Only one task can be active and doing measurement at a time. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 29 SignalShark - User Interface Manual Screen Layout 3) Task Bar > Browser like tap bar, that enables quick switching between measurement settings 3 and different task types. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 30 Task Types To support a wide variety of measurement applications, SignalShark provides several types of tasks: (Scan) Spectrum Mode > This task type supports measuring the spectrum with full frequency span of 8 kHz up to 8 GHz within one measurement and a maximum measurement speed of 40 GHz/s. RT Spectrum Mode > The Real-Time Spectrum task type enables real-time spectrum measurements with a frequency span of up to 40 MHz. This frequency span will be acquired simultaneously in frequency and also gapless in time with 3.125 µs POI. Auto DF Mode > The Auto Direction Finding task type supports control of the automatic DF antennas and handles the calculation of bearings out of the DF data. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 31 SignalShark - User Interface Manual Screen Layout 4) Views A view is a window containing a specific visual representation of measurement data. > The currently selected View is marked by a blue border. > The type, arrangement and size of a View 4 can be adapted by the user. Note: It is possible to save the current 4 configuration and arrangement of Tasks and Views into setup files. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 32 SignalShark - User Interface Manual Screen Layout Screen Overview 5) Button Bar > Provides access to the measurement and display settings of the currently selected View. Note: The content and layout of the "Button Bar" depends on the currently selected View. © Narda Safety Test Solutions GmbH www.narda-sts.com 5 Slide 33 SignalShark - User Interface Manual Screen Layout Screen Overview 6) Measurement Information Bar > Displays the most relevant settings of the currently selected View. Note: The content and layout of the "Measurement Information Bar" depends on the currently selected View. © Narda Safety Test Solutions GmbH 6 www.narda-sts.com Slide 34 SignalShark - User Interface Manual Basic Operation The basic operating steps © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 35 SignalShark - User Interface Manual Basic Operation Touch Screen Control SignalShark uses two basic touch gestures > Single Tap > Swipe © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 36 SignalShark - User Interface Manual Basic Operation Add new Task Step 1 The creation of a measurement task is the prerequisite for being able to perform a measurement at all. To add a new measurement task: > Tap on the Edit Task icon in the Task Bar or > Press the "Task" hard key © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 37 SignalShark - User Interface Manual Basic Operation Add new Task Step 2 > Tap on the "Add Task" button in the "Tasks" Button Bar. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 38 SignalShark - User Interface Manual Basic Operation Add new Task Step 3 > Browse the "Task Types" list. > Tap on the desired task type. Note: It is possible to save user defined task configurations as setups. A tap on the Predefined Setups item will open the setup menu from where a predefined setup can be loaded. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 39 SignalShark - User Interface Manual Basic Operation Maximizing a View A View can be maximized by a single tab on the maximize Icon > > Tapping again on the button will resize the View. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 40 SignalShark - User Interface Manual Basic Operation Change View Arrangement To change the arrangement of the Views: > Tap on the Menu Tool button > Tap on the Configure Task Views button. The "Configure Task Views" submenu opens © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 41 SignalShark - User Interface Manual Basic Operation Add View To add a View to the Task: > Tap on the desired View Type in the "Configure Task Views" Button Bar > Tap on the desired position of the new View. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 42 SignalShark - User Interface Manual Basic Operation Change View Position Step 1 To change the position of a View: > Tap on the Move Button © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 43 SignalShark - User Interface Manual Basic Operation Change View Position Step 2 > Tap on the desired position. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 44 SignalShark - User Interface Manual Basic Operation Delete View To delete a View from the Task: > Tap on the Delete Button © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 45 SignalShark - User Interface Manual Basic Operation Back to the Main Menu To get back to the main menu: > Tap on the header button of the "Configure Task Views" Button Bar or > Press the "Esc/Back" hard key Note: This is the default way to leave a submenu. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 46 SignalShark - User Interface Manual Basic Operation Show the Amplitude Menu To display the Amplitude Menu: > Tap on the Parameter Split Button > Ref. Lev. | Atten. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 47 SignalShark - User Interface Manual Basic Operation Amplitude Menu The Amplitude Menu contains manly settings to adapt the measurement to the current signal level like: > Reference Level > Attenuator It contains also the RF input selection © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 48 SignalShark - User Interface Manual Basic Operation Show the Frequency Menu To display the Frequency Menu: > Tap on the Parameter Button > Fcent/Fstart or > Fspan/Fstop © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 49 SignalShark - User Interface Manual Basic Operation Frequency Menu The Frequency Menu displays all frequency related parameters: It contains also the selection of the Rotary Knob input mode. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 50 SignalShark - User Interface Manual Basic Operation Set Frequency Span by Touch The frequency span can be set by selecting/drawing a horizontal range inside the graph from the left to the right. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 51 SignalShark - User Interface Manual Basic Operation Set Frequency Span by Touch Dragging from right to the left within the graph area will double the span. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 52 SignalShark - User Interface Manual Basic Operation Y-Axis Auto Range The display range of the y-axis can be automatically adapted by a tap on the Auto Range button. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 53 SignalShark - User Interface Manual Basic Operation Set Center Frequency by Touch The center frequency can be set by dragging the frequency axis to the left or to the right. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 54 SignalShark - User Interface Manual Basic Operation Marker Menu To open the Marker Menu > Tap on the Marker Menu Tool Button or > Press the hard key "Marker" © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 55 SignalShark - User Interface Manual Basic Operation Add Marker Select one to eight markers in the marker menu to add a marker. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 56 SignalShark - User Interface Manual Basic Operation Change Marker Position by Touch To change the marker position 1) Tap on the marker label to select it 2) Then drag the marker by it's label to the desired position. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 57 SignalShark - User Interface Manual Basic Operation Change Marker Settings Step 1 To change marker settings > Tap on the Marker Config. button in the "Marker" Button Bar © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 58 SignalShark - User Interface Manual Basic Operation Change Marker Settings Step 2 > Select a category tap in the "Marker Config" menu. > Tap in the table cell you want to change. > I.e. a tap in the cell "Type" toggles the marker type from normal marker to delta marker. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 59 SignalShark - User Interface Manual Basic Operation Change Device Settings Step 1 To change a device setting like the display brightness: > Tap on the Device Settings Tool Button The Device Settings menu will appear. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 60 SignalShark - User Interface Manual Basic Operation Change Device Settings Step 2 > Tap into the table cell of the setting you want to change A Parameter Edit Window will appear where the new setting can be entered. Note: Editable table cells have a different color than headlines or table cells containing a description. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 61 SignalShark - User Interface Manual Basic Operation Select Working Directory Step 1 The Working Directory defines the place (drive and folder) where data is saved to. To change the current Working Directory: > Tap on the Data Logger Tool Button The Data Logger menu will appear. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 62 SignalShark - User Interface Manual Basic Operation Select Working Directory Step 1 > Select the drive/folder that should be set as Working Directory > Tap on "Set as Working Directory" Note: The actual Working Directory is marked with a green dot. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 63 SignalShark - User Interface Manual Localization in three Steps with AutoDF Using AutoDF Task © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 64 SignalShark - User Interface Manual Localization in three Steps with AutoDF 1) Load a Predefined Setup > Open the "Add Task" menu > Select the "Predefined Setups" item © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 65 SignalShark - User Interface Manual Localization in three Steps with AutoDF 1) Load Predefined Setup > Select a predefined setup from the AutoDF folder that fits best to your signal Static: > The antenna is installed on a tripod or a mast > Map. Mode is "Disc. Localization" (Tap on "Save" to store a bearing) Vehicle: > The antenna is mounted on a vehicle > Map. Mode is "Cont. Localization" (Bearings are recorded into a file) © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 66 SignalShark - User Interface Manual Localization in three Steps with AutoDF 2) Adjust Settings > Adjust the bearing settings according to your signal > Ftune > CBW > Attenuation > Adjust the bearing configuration settings according to your signal conditions > DF Squelch > Min. DF Quality © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 67 SignalShark - User Interface Manual Localization in three Steps with AutoDF 3) Start Localization > Select the Map View (optional) > Tap on "Start Localization" Note: The default "Localization Area" is 50 km x 50 km around your current GNSS position. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 68 SignalShark - User Interface Manual Localization in three Steps with AutoDF 3) Start Localization Drive an "L" Pattern To get the fastest and most reliable localization result possible, the most practical approach has proven to be as follows: > Drive 3 to 4 kilometers straight ahead in one direction > Then look at the heat map and turn left or right depending on the result and drive again some kilometers Note: An ideal localization is the result of ideal bearings intersecting at right angles as in an "L" pattern. © Narda Safety Test Solutions GmbH www.narda-sts.com Slide 69