User Manual for Qlight models including: S125D series Signal Warning Light and Alarm Sounder Combinations, S125D series, Signal Warning Light and Alarm Sounder Combinations, Alarm Sounder Combinations, Sounder Combinations
2022-08-07 — Please remove any objects that can interrupt ventilation around the product. 2. Please turn off the power of the product immediately if it fails to operate ...
S125DLR-WA-24-G - Đèn tín hiệu/cảnh báo kết hợp còi điện QLIGHT
File Info : application/pdf, 8 Pages, 2.27MB
DocumentDocumentSignal/ Warning Light and Alarm Sounder Combinations S125D series 20 50 54 30 50 105 HORN Thank you for purchasing Qlight's products. Please read this user manual carefully prior to installation and operation to ensure safe and correct use. Precautions for Safety Failure to follow the instructions below may cause a loss of life or serious physical injury. 1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.) 2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury, malfunction or damage to the product.) 3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to follow this may cause damage to property, fire, electric shock and loss of life.) Precautions for Correct Use Failure to follow the proper instructions may cause damage to property, the product, and or malfunction of the product that would void the warranty. 1. Please remove any objects that can interrupt ventilation around the product. 2. Please turn off the power of the product immediately if it fails to operate properly. 3. Carefully wire the product according to each product's specification. 4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product. 5. Do not apply excessive force/impact to the product. 6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock. Ordering Specifications S125D - WA - 220 - R [Model number] | [Sound] | [Voltage] | [Color] | · S125DLR · S125DL · S125DS · S125D · WS- Warning sounds · WM- Melodies · WA- Alarms · WV- Customizable sounds · 12-DC12V · 24-DC24V · 110- AC110V · 220- AC220V R-Red A-Amber G-Green B-Blue Please scan the QR code for more detailed product information. www.qlight.com 1 Specifications Model number Voltage Bulb specifications Current Volts/Watts Configuration Part# DC12V 1.266A 12V10W T16x35 15S 9 S125D DC24V AC110V 0.766A 0.187A 24V10W T16x35 15S 10 12V10W T16x35 15S 9 AC220V 0.094A 12V10W T16x35 15S 9 CE compliant : DC24V, AC110V/220V Sound pattern and volume Certificates · WS- 5 Warning Sounds : Max. 105dB · WM- 5 Melodies : Max.105B · WA- 5 Alarms : Max.103dB · WV- 5 Customizable sounds : Max.95dB Weight 1.00Kg 1.41Kg Color R-Red A-Amber G-Green B-Blue Model number Voltage DC12V~24V S125DL AC110V AC220V DC12V S125DLR DC24V AC110V AC220V DC12V~24V S125DS AC110V AC220V Current Max. 0.520A 0.125A 0.065A 0.483A 0.327A 0.120A 0.060A Max. 1.330A 0.230A 0.155A Sound pattern and volume · WS- 5 Warning Sounds : Max. 105dB · WM- 5 Melodies : Max.105B · WA- 5 Alarms : Max.103dB · WV- 5 Customizable sounds : Max.95dB CE compliant : DC24V, AC110V/220V · Protection rating :IP54 · Ambient operating temperature : -20°C to +50°C (S125D, S125DLR) -30°C to +50°C (S125DL, S125DS) Certificates Weight 0.76Kg 1.16Kg 0.92Kg 1.29Kg 0.78Kg 1.23Kg Color R-Red A-Amber G-Green B-Blue 103 Dimensions Ø115 S125D/ S125DL/ S125DLR/ S125DS Ø10 CABLE ENTRY PCD70 (Units : mm) 215 112 Ø119 360°/3-M5 BOLT 15 2 Wiring Instructions S125D/ S125DL/ S125DLR/ S125DS-DC/AC Red(R) Amber(A) Green(G) Blue(B) White(W) EXTERNAL CONTACT Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 Black(BK) White(W) Black(BK) Fuse Common Power S125DL-DC/AC EXTERNAL TRANSISTOR-NPN Red(R) Amber(A) Green(G) Blue(B) White(W) Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 Black(BK) White(W) Black(BK) Common Fuse Power S125D/S125DLR-AC compatible type Red(R) Amber(A) Green(G) Blue(B) White(W) Black(BK) Red(R) White(W) Black(BK) Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 Common Fuse Power · External power line - UL1015 AWG18(0.75sq) x 2C 400mm · External signal line - UL1007 AWG22(0.3sq) 400mm · AC compatible type shall be connected the black and white wires when using AC110V, and the black and red wires when using AC220V. Sound Tone Combination of Standard Product Volume Adjustment Category Sound pattern Channel Sound tone Ch1 Fire Ch2 Emergency WS 5 Warning Ch3 Ambulance sounds Ch4 Machinery Fault Ch5 High Expansion Ch1 Sweet Home Ch2 For Elise 5 Melodies WM Ch3 Cuckoo's Waltz Ch4 Piano Sonata Ch5 Turkish March Ch1 Beep Intermittent Ch2 Door Chime WA 5 Alarms Ch3 Phone Ring Ch4 PI.PI.PI Short Ch5 Tripping Beat WV 5 Customizable Ch1- sounds Ch5 Available upon request(customized voice type) Volume (Max.) 105dB 105dB 103dB 95dB Volume Dial MAX. VOL. · The volume output of this product MIN. is adjustable. · Turn the volume dial clockwise to increase the volume, and turn counter clockwise to decrease the volume. · There will be no sound when the dial is put at MIN. Parts Definition/ Installation S125D S125DS S125DLR S125DL Light bulb Xenon bulb Lens(AS) LED Unit Resonator (Material:ABS) Rubber spacer Reflector (Heat resistant ABS) LED Unit Flange nut · First, remove the flange nuts from bolts and place the product through the mounting surface holes. · Fasten the flange nuts on the opposite side of the mounting surface until the product is tightened securely. 3 Light Function Selection/ Mounting Hole Specification Light Function Selection(125DL only) · Please refer to the chart below to use light function selection switch located inside the product. Mounting Hole Specifications · Machine holes on the mounting surface referring to the diagram below. Min. Ø5 CABLE ENTRY 360°/3-Ø6 HOLES PCD70 L : Steady LF : Flashing · Default function is set at steady LED. Select the desired function for your application during installation. Light bulb/ Xenon Bulb Replacement lnstructions Bulb Replacement Instructions(S125D model only) Xenon Bulb Replacement instructions(S125DS only) Assemble bulb Disassemble bulb Disassemble xenon bulb Assemble xenon bulb · Please wait at least 1 minute after turning off the power before replacing the bulb. · In order to dissemble the bulb, please push down the bulb() lightly and screw it counterclockwise. · In order to put the bulb in to the unit, please place the bulb() in the socket() and screw it clockwise while lightly pushing down the bulb. · Please wait at least 30 mimutes after turning off the power before replacing the xenon bulb. · Please pull out the entire xenon bulb structure to disassemble. · For xenon bulb assembly, please ensure the connector portion of the xenon bulb structure matches the pin location. Installation Environment and Protection Rating · This product is designed for use with protection rating of IP54. · If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating indicated(IP54), it may cause malfunction or damage to the product. · In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside- down positions where water can potentially penetrate into the product and impact it's operation. · For further information, please visit our website (www.qlight.com). 4 Product installation direction Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product. BEACON/SIGNALING LIGHT Power cord inlet part shall not be facing the sky. For products with a protection rating of less than IPX4, please install it vertically. ELECTRONIC SOUNDER/SIGNAL HORN Sounder part shall not be facing the sky. HEAVY-DUTY & EXPLOSION PROOF SIGNALINGS Sounder part shall not be facing the sky. SIGNAL TOWER LIGHTS Power cord inlet part shall not be facing the sky. For products with a protection rating of less than IPX4, please install it vertically. MEMO MEMO For your safety Specification and dimensions listed in this catalogue subject to change without notice for product quality improvement. The newest product information is available on our website.(www.qlight.com) Please read the instruction manual attached to the product carefully before installation and use. Qlight Co., Ltd. www.qlight.com | trade@qlight.com Head Office | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154 Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111) Qlight OverSEAs Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100 Qlight Public Relations & Marketing Team Office | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017 Qlight USA, Inc. www.qlight.com www.qlightusa.com | sales@qlightusa.com 3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 - 408 - 519 - 5740 Fax. +1 - 408 - 519 - 5739 SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | qlightcn@qlight.com China Factory/ Shanghai Sales Office | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86-21-6651-7100 Fax. +86-21-6315-3929 China Factory Site 2 (Qidong) | #33, Haiyan Road, Qidong High-tech Industrial Development Zone, Qidong, Jiangsu Province, China Tel +86- 513- 8384- 9999 Fax +86- 513- 8384- 9910 Product Operation Inquiry / Customer Support +82-51-620-4100 You can expect prompt service if you have exact information such as model name, symptom, telephone number and address. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507) Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805) www.qlight.com EN - S125D - 2205A