User Manual for CCEI models including: M12KCA, M12BCA, M12KCA Underwater LED Lighting, M12KCA, Underwater LED Lighting, LED Lighting, Lighting

CCEI Mini-Brio Cool White Mini-LED Nicheless Light | 12W 12V 1.5" MPT 50 Ft. Cable | PK10R300/50 V03

Technical Manual Mini BRIO M12CA (& M12KCA, M12BCA)


File Info : application/pdf, 8 Pages, 566.52KB

PDF preview unavailable. Download the PDF instead.

179312 2022725145323
Technical Manual Mini BRIO M12CA (& M12KCA, M12BCA)
Underwater LED lighting
Table of Contents
1. Packaging Contents ..................................................................................................................... 2 2. Technical characteristics ............................................................................................................. 2 3. Description .................................................................................................................................. 3
3.1. Warnings .......................................................................................................................... 3 3.2. Technical support ............................................................................................................. 3 4. Installation .................................................................................................................................. 4 4.1. Wall through installation .................................................................................................. 4 4.2. Placement in a wall .......................................................................................................... 6 4.3. Electrical Connections ...................................................................................................... 7 5. Transformer Power ..................................................................................................................... 8 A. Declaration of Conformity ....................................................................................................... 8
Read all of this leaflet carefully before installing, operating or using this product.
MPNT0325 v1.0EN (05/02/2016)

Technical Manual

Mini BRIO M12CA (& M12KCA, M12BCA)

v1.0EN

1. Packaging Contents
1 Mini BRIO M12 projector with
· Locking/unlocking tool · 2xAWG18 cable: Depending model
­ 4,6m (15ft) ­ 15,2m (50ft) ­ 30,4m (100ft) · Wall through: Depending model ­ Wall through PF10R191 for fiberglass or concrete pool (supplied with 2" gasket + 2" locknut) ­ Wall through PF10R192 for liner pool (supplied with 2" gasket + 2 liner gasket + 4 inox screws
+ liner flange + 2" locknut) · Projector / Wall through O-ring (D35xd3,5mm) · Technical manual (this document)
2. Technical characteristics

Dimensions Installation Power supply Power consumed
Weight

Ø 47 mm (1-11/16in) / length 84mm (3-5/16in) Only in a threaded 1.5" niche ref. PF10R191 or PF10R192
Voltage: 12 V~ AC / Frequency: 50Hz/60Hz 14W

Cable lenght Projector only Complete box

4,6m (15ft)

0,5kg (1,1lb)

1,2kg (2,6lb)

15,2m (50ft)

1,2kg (2,6lb)

1,9kg (4,2lb)

30,4m (100ft)

2,2kg (4,4lb)

2,9kg (6,4lb)

3 monochrome power LEDs

LED type

PK10R300 (M12) PK10R301 (M12K) PK10R302 (M12B)

Cool White (~6000°K) Warm White (~3000°K)
Blue

IP Rating Max light stream

Risk group 1 (low risk) according to IEC62471:2006 IP-68

PK10R300 (M12) PK10R301 (M12K) PK10R302 (M12B)

866 lm max. 866 lm max. 160 lm max.

The projector must never be powered other than in water.

www.ccei.ca

2

Technical Manual

Mini BRIO M12CA (& M12KCA, M12BCA)

v1.0EN

3. Description
BRIO Mini BRIO M12 LED projector are designed to replace incandescent lighting, to reduce your energy consumption and to light your swimming pool.
3.1. Warnings
This product must be installed by a licensed or certified electrician or a qualified pool professional in accordance with the current National Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local installation codes and ordinances must also be adhered to. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock, and may also cause damage to power source. Always disconnect the power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to service person, pool users or others due to electrical shock.

For countries in compliance with International Electrotechnical Commission (IEC) regulatory standards: The light fixture must be installed by a licensed or certified electrician or a qualified pool service person, in accordance with current IEC 364-7-702 and all applicable local codes and ordinance. Improper installation will create an electrical hazard, which could result in death or serious injury to pool user, installer or other due to electrical shock and may also cause damage to the property.
3.2. Technical support
Website : www.ccei.ca / Phone : +1.514.649.7748

www.ccei.ca

3

Technical Manual

Mini BRIO M12CA (& M12KCA, M12BCA)

v1.0EN

4. Installation
4.1. Wall through installation
4.1.1. Fiberglass pool
Prior to installing, drill a hole in the pool using a 60-mm (2 3/8-in) diameter cylinder saw. The wall through is connected on the rear to a 1,5" threaded coupling.

4.1.2. Concrete pool
Assemble a pipe of sufficient length with a 1,5" threaded coupling onto the wall through before sealing the assembly.

www.ccei.ca

4

Technical Manual

Mini BRIO M12CA (& M12KCA, M12BCA)

v1.0EN

4.1.3. Concrete + liner pool
Assemble a pipe of sufficient length with a 1,5" threaded coupling onto the wall through before sealing it.

Then glue a first gasket before placing the liner ;

www.ccei.ca

5

Technical Manual

Mini BRIO M12CA (& M12KCA, M12BCA)

v1.0EN

4.1.4. Panels + liner pool
Prior to installing, drill a hole in the pool using a 80-mm (3 1/8-in) diameter cylinder saw. Think to glue the first liner gasket before installing it.

The wall through is connected on the rear to a pipe with a 1,5" threaded coupling.
4.2. Placement in a wall
BRIO Mini BRIO M12CA (& M12KCA, M12BCA) LED projectors must only be installed in a threaded 1.5" niche ref. PF10R191 or PF10R192. We recommend that installation is performed by a professional.

www.ccei.ca

6

Technical Manual
4.2.1. In wall through

Mini BRIO M12CA (& M12KCA, M12BCA)

v1.0EN

1. Pass the gasket and the projector cable through the wall passage up to the connection box. 2. Push and screw the projector to the back. 3. Use provided tool to securely screw the projector.
4.3. Electrical Connections
Installing this product could expose you to an electric shock. We strongly recommend that you use a qualified professional. An installation error could put you at risk and irreversibly damage the product and the equipment connected to it.
In compliance with the current National Electrical Code (NEC), underwater lighting must always be supplied with SELV (Safety Extra Low Voltage). Turn off the power supply upstream before doing anything to the electrical installation.
Risk of Electrical Shock. Connect only to a circuit protected by a ground-fault circuit-interrupter (GFCI). If you cannot verify that the circuit is protected by a GFCI, contact a qualified electrician.
THE LED LIGHT AND PLASTIC NICHE FORM A COMPLETE NON-METALLIC LOW VOLTAGE LIGHTING SYSTEM. THIS CONFIGURATION DOES NOT REQUIRE BONDING OR GROUNDING WHEN POWERED BY A LISTED TRANSFORMER AND INSTALLED IN COMPLIANCE WITH THE CURRENT NATIONAL ELECTRIC CODE (NEC).
The electrical connection must be performed dry, in a sealed connection box whose cable glands must be tightened in order to avoid any water infiltration.
Once startup and the operation tests are complete, it is recommended to drown the connection with a reusable soft hydrophobic insulating gel. (ref. CCEI PNSP0002)

www.ccei.ca

7

Technical Manual

Mini BRIO M12CA (& M12KCA, M12BCA)

v1.0EN

The soft external cable of this lighting system cannot be replaced.
If this cable is damaged, the lighting system must be disposed of or returned to the manufacturer for possible reconditioning.

5. Transformer Power

The transformer to be used must have a secondary voltage of 12V (12.5V depending on the model). Transformer Power

The power of the transformer must be in line with

the power of the projectors to be connected.

50VA

In any case, the sum of the powers of the projectors 100VA

must remain below or equal to the power of the

transformer.

300VA

Max no. of Mini BRIO M12 3 7 21

It is preferable to use power supplies from the same manufacturer.

A. Declaration of Conformity
The Company CCEI Inc. (Québec 1170122155) declares that the product Mini BRIO M12CA (& M12KCA, M12BCA) satisfies the safety and electromagnetic compatibility requirements of European directives 2006/95/EC and 2004/108/EC and is UL listed under file E471596.

Distributor's stamp

Pierre-Yves Flattot Montreal, 05/02/2016

Date of Sale: . . . . . . . . . . . . . . . . . . . . . . . Serial No: . . . . . . . . . . . . . . . . . . . . . . . . . . .

www.ccei.ca

8



References

PDFium PDFium