BIOPAC NIBP100D Noninvasive Blood Pressure Monitoring System

Product Sheet

Overview

The BIOPAC NIBP100D Noninvasive Blood Pressure Monitoring System is designed for measuring blood pressure in subjects ranging from small children (approximately 4-5 years) to large adults.

Key Features

System Description

The NIBP100D system provides a continuous, beat-to-beat blood pressure signal recorded from the fingers. It outputs a waveform similar to a direct arterial pressure waveform and displays systolic, diastolic, mean blood pressure, and heart rate.

It utilizes a double finger cuff, comfortable and easy to place, available in three sizes to accommodate various age groups and sizes. The system interfaces with BIOPAC MP160/150 or MP36/36R/35/45 Data Acquisition Systems via specific interface connectors and cables. The AcqKnowledge or BSL PRO software visualizes the blood pressure signal and provides detailed beat-to-beat analysis.

The NIBP100D is calibrated using a standard blood pressure cuff on the upper arm. The unit automatically takes a measurement for calibration. During recording, it alternates between fingers to relieve pressure, with user-selectable intervals up to 60 minutes. Calibration readings are taken periodically to ensure accuracy.

Setup and calibration take less than three minutes. The system employs a vascular unloading technique, a refined version of the Penáz principle, for continuous noninvasive blood pressure measurement using concentrically interlocking control loops.

Hyperbaric/Hypobaric Chamber Setup Guidelines

Specifications

For complete specifications, refer to the NIBP100D User Manual available on the BIOPAC website.

Components

Electrical Properties

Output

Interface

External Mains Adapter

Parameter Classification

Measuring Range

Inflation Pressure

Compliance and Approvals

Intellectual Property

Patents

The NIBP100D CNAP™ Monitor 500 is CE and FDA approved.

Important Notes

Electric and magnetic fields may interfere with the functional reliability of the device. Avoid using the NIBP100D CNAP™ Monitor 500 close to devices emitting powerful electromagnetic fields, such as x-ray equipment, diathermy applications, or magnetic resonance tomographs.

PDF preview unavailable. Download the PDF instead.

NIBP100D-Product-Sheet PDF Complete 4.2.11.2002

Related Documents

Preview BIOPAC MP System Hardware Guide: Connect, Set Up, and Utilize Advanced Data Acquisition
Explore the BIOPAC MP System Hardware Guide for comprehensive instructions on connecting and setting up signal conditioning and amplifier modules. Learn about the MP160, MP150, MP36, and MP45 systems, applications, and essential hardware specifications for life science research.
Preview Biopac Student Lab 4.1 BSL PRO Tutorial Guide
A comprehensive tutorial for BIOPAC's BSL PRO software, covering data acquisition, analysis, and display features for life science applications using BIOPAC MP hardware (MP36, MP35, MP45). Includes guidance on setup, recording, sample data analysis, and journaling.
Preview BIOPAC BSL PRO Lesson H29: Measure Basal Metabolic Rate
Learn how to set up and use the BIOPAC BSL PRO system for measuring Basal Metabolic Rate (BMR) through indirect calorimetry, including VO2 measurement and analysis.
Preview BIOPAC MP System Hardware Guide
Comprehensive guide to the BIOPAC MP System, detailing hardware setup, components, applications, and maintenance for life science research.
Preview BIOPAC BSL Home Quick Guide: Data Acquisition and Analysis
A concise guide to using BIOPAC's BSL Home software for physiology data acquisition, analysis, and lessons, covering the BSL display, menu commands, running lessons, and troubleshooting common issues.
Preview BIOPAC BSL Driver Guide: Installation and Troubleshooting
Comprehensive guide for installing and updating BIOPAC MP35 and MP30 USB drivers, including troubleshooting steps for Windows XP and Vista.