Installation Guide for iO-MZR models including: iO-MZR, iO-MZRTM, iO-MZRTM Motorized Zone Register, iO-MZRTM, Motorized Zone Register, Zone Register, Register
When the iO-MZR™ is used with a zone control system, the register actuator is wired to the proper damper terminals on the zone control panel.
File Info : application/pdf, 2 Pages, 529.80KB
DocumentDocumentiO-MZRTM Motorized Zone Register When used as a stand-alone register Installation Instructions The iO-MZRTM Motorized Zone Register can be used as a stand-alone register. It is recommended that no more than 30% of the existing registers be replaced with iO-MZRTM registers. iO-MZRTM registers should not be installed in the same room as the HVAC unit thermostat. When the iO-MZRTM is used as a stand-alone register, it can be wired to a hardwired or battery powered thermostat using standard 18-gauge wire. However, if the thermostat wire is run through the supply duct work, use plenum rated wire to comply with local code. The thermostat should be configured for manual heating or cooling mode of operation since it does not control the HVAC equipment. Time delays should also be disabled to provide an immediate reaction on a call for heating or cooling. When the thermostat calls for heating or cooling, the MZRTM register is powered open. When the space temperature reaches setpoint, the MZRTM register spring returns close. WIRING DIAGRAM FOR BATTERY POWERED THERMOSTAT OPERATION JUMPER `W' AND `Y' WYG R WIRING DIAGRAM FOR HARDWIRED THERMOSTAT OPERATION JUMPER `W' AND `Y' WYG RC iO-MZR AUTOMATIC ZONE REGISTER iO-MZR AUTOMATIC ZONE REGISTER ACTUATOR PO/SC 24V 120V 24 VAC TRANSFORMER ACTUATOR PO/SC 24V 120V 24 VAC TRANSFORMER iO-MZRTM Motorized Zone Register When used with a zone control panel Installation Instructions When the iO-MZRTM is used with a zone control system, the register actuator is wired to the proper damper terminals on the zone control panel. The iO-MZRTM wires the same as a standard powered closed / spring return open zone damper. ZONE PANEL ZONE 1 STAT 72° ZONE 1 REGISTER ZONE 1 REGISTER TRANS. 24VAC ZONE 2 STAT 70° ZONE 2 REGISTER ZONE 2 REGISTER Up to six registers may be connected to a single zone WIRING SUGGESTIONS The most common methods used to run wire inside the duct work is as follows: 1. Drill a hole in the register boot and run the wire in a conventional manner. 2. Use a fish tape to pull the wire through the duct. 3. Use a duct cleaning vacuum machine to draw a plastic bag with an attached line to pull wire through the duct. If wiring from actuator is run inside the duct work, plenum rated wire must be used. AVAILABLE SIZES 4" X 10" 4" X 12" 4" X 14" 6" X 12" COLORS Tan and White APPLICATION NOTES MZR zone registers are not designed to work in a 3-1/2" stud wall. SPECIFICATIONS Operating Voltage: 24VAC Amperage: 0.26A VA Rating: 6.5VA Configuration: Spring Open/Power Close Indianapolis, IN 46237 www.iohvaccontrols.com For Technical Support Call Toll Free: 866-225-5032 iO-06-1181-022124