Instruction Manual for SENECA models including: ZE-4DI-2AI-2DO, Z-4DI-2AI-2DO, ZE-2AI, Automation Interfaces Ethernet, ZE-2AI Automation Interfaces Ethernet, Interfaces Ethernet, Ethernet
Z-4DI-2AI-2DO | Moduli I/O Misti | SENECA
File Info : application/pdf, 6 Pages, 291.77KB
DocumentDocumentINSTALLATION MANUAL ZE-4DI-2AI-2DO Z-4DI-2AI-2DO ZE-2AI PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user's safety at risk. The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment. The warranty shall become null and void in the event of improper use or tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manual are not followed. WARNING: The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is available via QR-CODE shown on page 1. The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to electrostatic discharges. Take appropriate measures during any operation. Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling). The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste. DOCUMENTATION ZE-4DI-2AI-2DO DOCUMENTATION Z-4DI-2AI-2DO DOCUMENTATION ZE-2AI SENECA s.r.l.; Via Austria, 26 35127 PADOVA ITALY; Tel. +39.049.8705359 - Fax +39.049.8706287 CONTACT INFORMATION Technical support support@seneca.it Product information sales@seneca.it This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The content of this document corresponds to the described products and technologies. Stated data may be modified or supplemented for technical and/or sales purposes. MI00582-0-EN INSTALLATION MANUAL 1/6 MODULE LAYOUT 35 mm 17.5 mm ZE-4DI-2AI-2DO ZE-2AI Z-4DI-2AI-2DO 111 mm 102.5 mm Single module dimensions LxHxD: 17.5 x 102.5 x 111 mm; Weight: 110 g; Enclosure: PA6, black Double module dimensions LxHxD: 35 x 102.5 x 111 mm; Weight: 110 g; Enclosure: PA6, black LED SIGNALS ON THE FRONT PANEL (ZE-4DI-2AI-2DO) LED IP / PWR IP / PWR Tx/Rx ETH TRF ETH LNK DI1, DI2, DI3, DI4 DO1, DO2 FAIL STATUS ON Flashing Flashing Flashing ON On / Off On / Off Flashing MEANING Module powered IP address acquired Module powered Waiting for IP address from the DHCP server Data transmission and reception on at least one Modbus port Packet transmission on Ethernet port Ethernet port connected Status of digital input 1, 2, 3, 4 Status of output 1, 2 Outputs in fail condition LED SIGNALS ON THE FRONT PANEL (Z-4DI-2AI-2DO) LED PWR Tx/Rx DI1, DI2, DI3, DI4 DO1, DO2 FAIL STATUS ON Flashing On / Off On / Off Flashing MEANING Module powered Data transmission and reception on at least one Modbus port: COM 1 port, COM 2 port Status of digital input 1, 2, 3, 4 Status of output 1, 2 Outputs in fail condition LED SIGNALS ON THE FRONT PANEL (ZE-2AI) LED STATUS MEANING IP / PWR IP / PWR FAIL ETH TRF ETH LNK Tx1 Rx1 Tx2 Rx2 ON Flashing ON Flashing ON Flashing Flashing Flashing Flashing Module powered and IP address acquired Module powered Waiting for IP address from the DHCP server At least one of the two analogue inputs is out of scale (underscale-overscale) Packet transmission on Ethernet port Ethernet port connected Modbus packet transmission from device to COM 1 port Modbus packet reception on COM 1 port Modbus packet transmission from device to COM 2 port Modbus packet reception on COM 2 port MI00582-0-EN INSTALLATION MANUAL 2/6 TECHNICAL SPECIFICATIONS CERTIFICATIONS ZE-4DI-2AI-2DO Z-4DI-2AI-2DO ZE-2AI https://www.seneca.it/products/ze-4di-2ai-2do/doc/CE_declaration https://www.seneca.it/products/z-4di-2ai-2do/doc/CE_declaration https://www.seneca.it/products/ze-2ai/doc/CE_declaration ZE-4DI-2AI-2DO Z-4DI-2AI-2DO ZE-2AI RS485 RS485 RS232 ETH RS485 RS485 RS232 USB ETH RS485 RS485 RS232 ETH INSULATION DI 1 DI 1 DI 2 DO 1 DI 2 DO 1 DI 3 DI 3 AI 1 DI 4 AI 1 AI 2 Input Output DO 2 Power DI 4 Input Output AI 1 DO 2 Power AI 2 Supply AI 2 Supply 1500 V ~ 1500 V~ Input Power Supply 3000 V ~ 3000 V~ Temperature: -25 ÷ + 70°C ENVIRONMENTAL CONDITIONS Humidity: 30% ÷ 90% non condensing Altitude: Up to 2000 m above sea level Storage temperature: -30 ÷ +85° Protection rating: IP20. ASSEMBLY IEC EN60715, 35mm DIN rail in vertical position. CONNECTIONS Removable 3-way screw terminals, 5 mm pitch for cable up to 2.5 mm2 Rear connector IDC10 for DIN bar 46277 RJ45 micro USB (Z-4DI-2AI-2DO) Voltage: 11 ÷ 40Vdc; 19 ÷ 28Vac 50 ÷ 60Hz POWER SUPPLY Absorption: Typical: 1,5 W @ 24Vdc, Max: 4 W (ZE-4DI-2AI-2DO Z-4DI-2AI-2DO) Absorption: Typical: 1,5 W @ 24Vdc, Max: 2 W (ZE-2AI) DIGITAL INPUTS only ZE-4DI-2AI-2DO Z-4DI-2AI-2DO Number of channels 4. Configurable PNP or NPN. Voltage input OFF < 4V, ON > 8V (max. 24 Vdc). Current input 20 mA. Max frequency 5 KHz. Absorbed current 3mA@12Vdc, 10mA@24Vdc. COUNTERS only ZE-4DI-2AI-2DO 4 32bit resettable counters on non-volatile memory. Z-4DI-2AI-2DO DIGITAL OUTPUTS only ZE-4DI-2AI-2DO Z-4DI-2AI-2DO Number of channels 2. SPDT free contact relay. Max. voltage 250Vac. Max. current 2 A. ANALOGUE INPUTS Number of channels 2. Voltage/Current configurable Input Voltage 0÷30 V. Precision 0.1% of full scale, Resolution: 16 bit Current input 0 ÷ 20mA precision 0.1% of full scale, Resolution: 16bit Input protection 40V / 25mA COMMUNICATION PORTS RS485 COM1 on IDC10 connector. RS485 or RS232 M10-M11-M12. Ethernet 100 base T RJ45 front (ZE-4DI-2AI-2DO, ZE-2AI) side micro USB port (Z-4DI-2AI-2DO) MI00582-0-EN INSTALLATION MANUAL 1500 V~ 3/6 INSTALLATION REGULATIONS The module has been designed for vertical installation on a DIN 46277 rail. For optimal operation and long life, adequate ventilation must be provided. Avoid positioning ducting or other objects that obstruct the ventilation slots. Avoid mounting modules over heat-generating equipment. Installation in the bottom part of the electrical panel is recommended. CAUTION These are open type devices intended for installation in a final casing/panel that offers mechanical protection and protection against the spread of fire. FACTORY IP ADDRESS The default module IP address is static: 192.168.90.101 WEB SERVER To access the maintenance Web Server with 192.168.90.101 factory IP address: Default user: admin, Default password: admin, http://192.168.90.101 ModBUS CONNECTION RULES 1) Install the modules in the DIN rail (120 max) 2) Connect the remote modules using cables of an appropriate length. The following table shows cable length data: -Bus length: maximum length of the Modbus network according to the Baud Rate. This is the length of the cables that connect the two farthest modules (see Diagram 1). - Derivation length: maximum length of a derivation 2 m (see Diagram 1). Lunghezza bus 1200 m Lunghezza derivazione 2 m Schema 1 Modulo 1 Modulo 4 Modulo 3 Ld Modulo 2 Modulo 5 Lunghezza del Bus Ld= Lunghezza derivazione For maximum performance, it is recommended to use special shielded cables, designed specifically for data communication. MI00582-0-EN INSTALLATION MANUAL 4/6 USB PORT (Z-4DI-2AI-2DO) The module is designed to exchange data according to the modes defined by the MODBUS protocol. It has a micro USB connector on the front panel and can be configured using applications and/or software programs. The USB serial port uses the following communication parameters: 115200,8,N,1. The USB communication port responds exactly like the serial ports, with the exception of the communication parameters. For more information, visit the site shown on page 1. Configurazione Atrnadmroitied AAPPPP conAfnigdurroaitdion Configurazione PC storaftmwaitree consoffitgwuararetioPnC CU -A-M- ICROO TG CU -A-MICROB CU-A- MICROB Check that the device in question is included in the list of products supported by the Easy Setup APP in the store. CONNECTOR IDC10 Power supply and Modbus interface are available using the Seneca DIN rail bus, via the IDC10 rear connector, or the Z-PC-DINAL-17.5 accessory. RS485 GND RS485 A RS485 B Power Supply AC / + Power Supply AC / - 1 IDC 10 Back connector (IDC 10) The illustration shows the meanings of the various IDC10 connector pins if signals are to be sent via them directly. SETTING THE DIP-SWITCHES WARNING The DIP-switch settings are read only at boot time. At each change, perform a restart. SW1 DIP-SWITCH: Through DIP-SWITCH-SW1 it is possible to set the IP configuration of the device: KEY DESCRIPTION 1 ON 0 OFF To obtain the configuration from the Flash memory, both SW1 DIP switch selectors must be set to OFF To reset the device to factory settings both SW1 DIP switches must be set to ON To force the device's IP address to the standard value of SENECA Ethernet products: 192.168.90.101 Reserved RS232/RS485 SETTING: RS232 or RS485 configuration on terminals 10-11-12 (serial port 2) SW2 1 ON RS232 ACTIVATION 0 OFF RS485 ACTIVATION DIP 1 DIP 2 MI00582-0-EN INSTALLATION MANUAL 5/6 ELECTRICAL CONNECTIONS Attention: the upper power supply limits must not be exceeded, as this might cause serious damage to the module. To meet the electromagnetic immunity requirements: - use shielded signal cables; - connect the shield to a preferential instrumentation earth system; - separate shielded cables from other cables used for power installations (transformers, inverters, motors, induction ovens, etc.). POWER SUPPLY Power supply Power supply Auxiliary voltage +12Vdc at 30mA 3 The power supply is connected to terminals 2 and 3. The supply voltage must be between: 2 11 and 40Vdc (indifferent polarity), or between 19 and 28 Vac. 1 The power supply source must be protected from any failures in the module by means of a suitably sized fuse. ANALOGUE INPUTS Voltage Active sensor current (4 wires) Passive sensor current (2 wires) + + 4GND 5AI1 6AI2 + 4GND + 5AI1 6AI2 1 12V 5A I1 6A I2 The module has two analogue inputs that can be configured via software as voltage or current. For the configuration software, see the user manual DIGITAL INPUTS (ONLY ZE-4DI-2AI-2DO and Z-4DI-2AI-2DO) NPN INPUT 15 +12V 14 DI2 13 DI1 PNP INPUT 12V 20mA 15 +12V 14 DI2 13 DI1 WITH EXTERNAL POWER Max 24V 15 +12V 14 DI2 13 DI1 18 DI4 17 DI3 0V 16 GND 18 DI4 17 DI3 16 GND DIGITAL OUTPUTS (ONLY ZE-4DI-2AI-2DO and Z4DI-2AI-2DO) N.A.1=19 CO.1=20 N.C.1=21 N.A.2=22 CO.2=23 N.C.2=24 COM2 SERIAL PORT 10 GND 11 A(+) 12 B (-) SERIAL PORT RS485 (SW2=OFF) 10 GND SERIAL 11 RX PORT RS232 12 TX (SW2= ON) 18 DI4 17 DI3 0V 16 GND The has two digital outputs with free contacts. The two figures show the internal relay contacts available. The module has a COM2 serial port configurable via the SW2 switch on terminals 10-11-12. MI00582-0-EN INSTALLATION MANUAL 6/6