Owner's Manual for Gibson models including: G8SD Series Single Stage Upflow Horizonta Gas Furnace, G8SD Series, Single Stage Upflow Horizonta Gas Furnace

TCPDF

G8SD Gas Furnace

FG8SD | Gas Furnace | Gibson | Literature Library

PDF preview unavailable. Download the PDF instead.

628f
TECHNICAL SPECIFICATIONS

G8SD Series
Single Stage Upflow/Horizontal Gas Furnaces
Induced Draft - 95+ AFUE, Ultra-Low NOx Input 50,000 - 100,000 Btuh
The gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing "appliance appearance." Design certified by UL for application in the United States.
This furnace series is approved and certified by the SCAQMD and the SJVAPC Districts in the state of California with NOx levels below 14 ng/J when operating on natural gas.

FEATURES and BENEFITS
· Ultra-low emissions: 65% less NOx than standard furnaces.
· 100% fired and tested: All units and each component are tested on the manufacturing line.
· Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
· Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
· Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
· 30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 100, 140 and 180 seconds).
· 30 second post purge: Increases life of heat exchanger. · Hot surface igniter: Innovative application of a silicon
nitride igniter. · Color coded wire harness: Designed to fit the
components, all with quick-connect fittings for ease of service and replacement. · High static blowers: All models equipped with high static blowers. · 45 second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a Nortek Global HVAC coil. · Flexible category IV venting system: May be vented with dedicated venting system or common vented with other category one appliances. · High efficiency blower assemblies: Maximize efficiencies and provide better temperature control, humidity control and air distribution. · Multi-speed direct drive blower: Energy-efficient, brushless DC (ECM). Designed to give a wide range of cooling capacities. · 7-segment LED for easy troubleshooting: Saves time by providing easy to read fault codes. · Integrated control board: Incorporates connections for electronic air cleaner and humidifier. Ergonomically located for ease of service. · Two piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws. · Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it's needed.

GAS FURNACE DIMENSIONS

ULTRA-LOW NOX UPFLOW/HORIZONTAL FURNACE

MODEL #'S

DIM. -A-

DIM. -B-

050U-T23A 070U-T24B 100U-T35C

14 1/4 17 1/2
21

12 5/8 15 7/8 19 3/8

NOTE: Dimensions shown in Inches.

DIM. -C12 7/8 16 1/8 19 7/8
3 1/4

2 3/4 22 1/2
25 3/8 22 1/2 Vent pipe (Ø 3")

T-stat (Ø 7/8)
Electric (Ø 7/8)
Gas (Ø 1 5/8)

34 1/2 17 1/4 17 7/8

28 LEFT SIDE

Condensate (Ø 1 1/16)

TOP VIEW B

FLANGES

19

Combustion Air

A

T-stat (Ø 7/8)

Vent pipe (Ø 3")

24 7/8

1 FRONT VIEW

23 1/2

BOTTOM VIEW C
Front Brace
Bottom Panel

Electric (Ø 7/8)

22 1/2 Gas (Ø 1 5/8)

4 Knockouts (both sides) Cond. (Ø 1 1/16)
23 RIGHT SIDE

15 1 1/4

GAS FURNACE COMPONENTS

Air / Fuel Mixing Tube

Gas Burner Head
Igniter / Flame Sensor Assembly
Access
In-Line Drain Asssembly
Pressure Transducer
Inducer Assembly
Inducer Motor
Alternate Single Pressure Switch Location
Blower Door Switch

Sight Glass Primary Air Limit Switch
Flexible Gas Line Dual Pressure Switch
Combustion Air Orifice Plate Gas Valve Single Pressure Switch (Factory Location)
Blower Limit Switch
Motor Choke

Furnace Control
Board

Transformer
Blower Assembly

2

Gas Furnace
Design Series
S = Single Stage T = Two Stage M = Modulating
A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal D = 95% Upflow/Horizontal E = 96% Upflow K = 80% Downflow L = 92.1% / 95.1% Downflow M = 95% Downflow N = 96% Downflow Q = 96.4+% AFUE Upflow/Horizontal

MODEL IDENTIFICATION CODE
G 8 S D 050 U T 23 A P

Powder Painted

Input Heating Capacity 050 = 50,000 070 = 70,000 100 = 100,000

Cabinet Width A = 14.25 B = 17.50 C = 21.00 D = 24.50
Cooling Airflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5 Tons
Motor Technology V = VSHE E = FSHE T = 5 Tap ECM
NOx C/D = 40 Ng/J or less NOx U = 14 Ng/J or less NOx

G8SD MODEL NUMBERS Input - Btuh (a) Heating Capacity - BtuH AFUE Motor H.P. - Speed - Type Motor FLA Rated Ext. SP - In. W.C. Temperature Rise Range - F Shipping Weights NOx

SPECIFICATIONS

-050U-T23A* 50,000 48,000 95.0
3/4 - 9 - ECM 8.4 0.5
30-60 115 <14ng/J

-070U-T24B* 70,000 67,000 95.0
3/4 - 9 - ECM 8.4 0.5
30-60 133 <14ng/J

-100U-T35C* 100,000 95,000 95.0
1 - 9 - ECM 11 0.5
35-65 153 <14ng/J

Description Side return filter kit

ACCESSORIES
G8SD KITS

SKU 541036

3

AIRFLOW DATA

MODEL NAME/ HEATING INPUT
G8SD

RETURN AIR VIA:

MOTOR SPEED

-050U-T23A*
50,000 BTU/h Input 48,000 BTU/h Output

Bottom Side

Tap 9 Tap 8 Tap 7 Tap 6* Tap 5** Tap 4 Tap 3 Tap 2 Tap 1*** Tap 9 Tap 8 Tap 7 Tap 6* Tap 5** Tap 4 Tap 3 Tap 2 Tap 1***

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

EXTERNAL STATIC PRESSURE (IN. W.C.)

0.1

0.2

0.3

0.4

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

970

45

935

47

915

48

880

50

875

50

835

53

810

54

770

57

835

53

795

55

765

57

935

47

915

48

880

50

845

52

850

52

815

54

780

56

745

59

815

54

775

57

740

59

MODEL NAME/ HEATING INPUT
G8SD

RETURN AIR VIA:

MOTOR SPEED

Tap 9

Tap 8

Tap 7

Bottom Only

Tap 6* Tap 5** Tap 4

Tap 3

-050U-T23A*
50,000 BTU/h Input 48,000 BTU/h Output

Tap 2 Tap 1*** Tap 9 Tap 8

Tap 7

Tap 6*

Left Side Only

Motor

Tap 5**

Tap 4

Tap 3

Tap 2

Tap 1***

COOLING AIRFLOW (CFM)

EXTERNAL STATIC PRESSURE (IN. W.C.)

0.1

0.2

0.3

0.4

0.5

0.6

CFM
1,420 1,310 1,180 1,085 970 875 835 650 550 1,410 1,290 1,145 1,045 935 850 815 605 495

CFM
1,395 1,270 1,145 1,050 935 835 795 590 485 1,380 1,260 1,115 1,015 915 815 775 575 470

CFM
1,360 1,245 1,115 1,015 915 810 765 560 450 1,350 1,230 1,090 980 880 780 740 530 410

CFM
1,330 1,215 1,085 985 880 770 725 520 405 1,315 1,195 1,055 950 845 745 700 495 365

CFM
1,300 1,180 1,050 950 845 735 690 465 330 1,285 1,160 1,030 920 805 715 675 445 320

(CFM)
1,280 1,145 1,020 920 810 700 655 430 290 1,255 1,135 995 885 775 665 620 390 260

0.7
(CFM)
1,245 1,120 990 890 780 665 615 380 250 1,225 1,100 960 855 745 625 575 325 160

0.8
(CFM)
1,220 1,095 955 855 745 630 580 340 195 1,200 1,070 920 825 695 585 540 235

NOTES: 1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 2. Data is shown without filter. 3. Temperature rises in the table are approximate. Actual temperature rises may vary. 4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 6. The "*" denotes the factory COOL setting, "**" denotes the factory HEAT setting, and "***" denotes factory FAN setting. If the Alternate
speed is to be used, the speed tap must be adjusted at the blower motor plug.

0.5

CFM

RISE

845

52

735

60

805

55

4

AIRFLOW DATA

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

MODEL NAME/ HEATING INPUT
G8SD

RETURN AIR VIA:

MOTOR SPEED
TAP

G8SD-070U-T24B*
70,000 BTU/h Input 67,000 BTU/h Output

9 8 7 6 ** Bottom Only 5 * 4 3 2 1 *** 9 8 7 6 ** Side Only 5 * 4 3 2 1 *** 9 8 7 6 ** Side + Bottom 5 * 4 3 2 1 ***

0.1 CFM RISE

EXTERNAL STATIC PRESSURE (IN. W.C.)

0.2

0.3

0.4

CFM RISE CFM RISE CFM RISE

0.5 CFM RISE

1,460 42 1,430 43 1,385 45 1,345 46 1,300 48 1,380 45 1,330 47 1,285 48 1,240 50 1,200 52 1,065 58

1,440 43 1,400 44 1,360 46 1,315 47 1,270 49 1,340 46 1,295 48 1,255 49 1,215 51 1,170 53

1,460 42 1,415 44 1,375 45 1,330 47 1,290 48 1,400 44 1,355 46 1,310 47 1,270 49 1,225 51 1,065 58

NOTES: 1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 2. Data is shown without filter. 3. Temperature rises in the table are approximate. Actual temperature rises may vary. 4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 6. The "*" denotes the factory (default) COOL setting, "**" denotes the factory (default) HEAT setting, and "***" denotes the factory (default) FAN setting. If an alternate speed is to be used, refer to the installation instructions for Speed Tap Selection.

5

AIRFLOW DATA

MODEL NAME/ HEATING INPUT
G8SD
G8SD-070U-T24B* 70,000 BTUH/h Input 67,000 BTU/h Output

COOLING AIRFLOW (CFM)

RETURN AIR VIA:

MOTOR SPEED
TAP

9

8

7

6 **

Bottom Only

5 *

4

3

2

1 ***

9

8

7

6 **

Side Only 5 *

4

3

2

1 ***

9

8

7

6 **

Bottom + Side

5 *

4

3

2

1 ***

0.1
CFM
1,775 1,640 1,565 1,460 1,380 1,065 860 625 660 1,715 1,600 1,515 1,440 1,340 1,025 830 585 695 1,820 1,675 1,585 1,460 1,400 1,065 860 650 680

EXTERNAL STATIC PRESSURE (IN. W.C.)

0.2

0.3

0.4

0.5

0.6

0.7

0.8

CFM CFM CFM CFM (CFM) (CFM) (CFM)

1,745 1,605 1,525 1,430 1,330 1,015 770 550 610 1,710 1,565 1,480 1,400 1,295 980 760 530 600 1,785 1,640 1,545 1,415 1,355 1,010 790 550 600

1,705 1,560 1,480 1,385 1,285 965 735 490 550 1,675 1,530 1,440 1,360 1,255 925 700 490 565 1,745 1,600 1,500 1,375 1,310 965 735 500 550

1,660 1,525 1,440 1,345 1,240 920 670 435 460 1,640 1,490 1,405 1,315 1,215 875 650 420 470 1,710 1,550 1,460 1,330 1,270 915 680 435 480

1,620 1,485 1,390 1,300 1,200 870 610 365 430 1,600 1,445 1,360 1,270 1,170 820 595 370 400 1,665 1,515 1,420 1,290 1,225 850 625 390 420

1,580 1,440 1,355 1,260 1,150 815 560
360 1,565 1,410 1,320 1,230 1,120 780 525
385 1,625 1,480 1,380 1,245 1,180 810 550
390

1,540 1,400 1,310 1,215 1,110 755 490
1,525 1,370 1,275 1,180 1,070 740 495
1,585 1,435 1,340 1,205 1,135 755 500

1,500 1,350 1,260 1,175 1,065 700 460
1,480 1,320 1,230 1,130 1,020 680 465
1,540 1,390 1,295 1,160 1,090 710 460

NOTES: 1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 2. Data is shown without filter. 3. Temperature rises in the table are approximate. Actual temperature rises may vary. 4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 6. The "*" denotes the factory (default) COOL setting, "**" denotes the factory (default) HEAT setting, and "***" denotes the factory (default) FAN setting. If an alternate speed is to be used, refer to the installation instructions for Speed Tap Selection.

6

AIRFLOW DATA

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

MODEL NAME/ HEATING INPUT
G8SD

RETURN AIR VIA:

MOTOR SPEED
TAP

G8SD-100U-T35C*
100,000 BTU/h Input 95,000 BTU/h Output

9 8 7 6 * Bottom Only 5 ** 4 3 2 1 *** 9 8 7 6 * Side Only 5 ** 4 3 2 1 *** 9 8 7 6 * Side + Bottom 5 ** 4 3 2 1 ***

0.1 CFM RISE --- ----- ----- --1,850 48 1,745 50 1,480 59

EXTERNAL STATIC PRESSURE (IN. W.C.)

0.2

0.3

0.4

CFM RISE CFM RISE CFM RISE

--- --- --- --- --- ---

--- --- --- --- --- ---

--- --- --- --- --- ---

1,790 49 1,745 50 1,700 52

1,690 52 1,645 53 1,590 55

1,420 62 1,360 65

0.5 CFM RISE --- ----- ----- --1,650 53 1,535 57

--- --- --- --- --- --- --- --- --- ----- --- --- --- --- --- --- --- --- ----- --- --- --- --- --- --- --- --- --1,785 49 1,740 51 1,690 52 1,640 54 1,590 55 1,690 52 1,640 54 1,595 55 1,540 57 1,490 59 1,435 61 1,375 64 1,300

--- --- --- --- --- --- --- --- --- ----- --- --- --- --- --- --- --- --- ----- --- --- --- --- --- --- --- --- --1,865 47 1,810 49 1,755 50 1,695 52 1,645 53 1,760 50 1,705 52 1,655 53 1,595 55 1,535 57 1,495 59 1,430 62 1,365 64

NOTES: 1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 2. Data is shown without filter. 3. Temperature rises in the table are approximate. Actual temperature rises may vary. 4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 6. The "*" denotes the factory (default) COOL setting, "**" denotes the factory (default) HEAT setting, and "***" denotes the factory (default) FAN setting. If an alternate speed is to be used, refer to the installation instructions for Speed Tap Selection.

7

AIRFLOW DATA

COOLING AIRFLOW (CFM)

MODEL NAME/ HEATING INPUT
G8SD

RETURN AIR VIA:

MOTOR SPEED
TAP

G8SD-100U-T35C*
100,000 BTUH/h Input 95,000 BTU/h Output

9

8

7

6 *

Bottom Only

5 **

4

3

2

1 ***

9

8

7

6 *

Side Only 5 **

4

3

2

1 ***

9

8

7

6 *

Bottom + Side

5 **

4

3

2

1 ***

0.1
CFM
2,250 2,055 1,900 1,850 1,745 1,480 1,315 1,140 1,025 2,155 1,980 1,835 1,785 1,690 1,435 1,265 1,095 980 2,245 2,080 1,915 1,865 1,760 1,495 1,325 1,175 1,040

EXTERNAL STATIC PRESSURE (IN. W.C.)

0.2

0.3

0.4

0.5

0.6

0.7

0.8

CFM
2,250 2,010 1,845 1,790 1,690 1,420 1,245 1,055 920 2,110 1,940 1,785 1,740 1,640 1,375 1,190 1,015 905 2,195 2,030 1,875 1,810 1,705 1,430 1,245 1,065 930

CFM
2,190 1,970 1,795 1,745 1,645 1,360 1,170 975 830 2,075 1,890 1,740 1,690 1,595 1,300 1,140 945 835 2,155 1,980 1,820 1,755 1,655 1,365 1,175 965 850

CFM
2,130 1,900 1,750 1,700 1,590 1,300 1,100 890 745 2,020 1,850 1,685 1,640 1,540 1,250 1,070 870 740 2,095 1,930 1,765 1,695 1,595 1,290 1,095 900 750

CFM
2,080 1,840 1,700 1,650 1,535 1,230 1,025 820 690 1,975 1,805 1,635 1,590 1,490 1,195 1,005 790 665 2,065 1,880 1,715 1,645 1,535 1,235 1,035 810 680

(CFM)
2,025 1,790 1,650 1,595 1,485 1,165 975 765 625 1,965 1,760 1,585 1,540 1,440 1,140 935 715 590 2,070 1,820 1,655 1,585 1,480 1,170 970 775 610

(CFM) (CFM)

1,975 1,730 1,575 1,535 1,420 1,110 915 705 580 1,950 1,710 1,545 1,490 1,390 1,080 875 665 525

1,915 1,675 1,520 1,470 1,365 1,055 860 660 500 1,900 1,650 1,495 1,440 1,340 1,020 815 615 440

2,015 1,765 1,600 1,530 1,430 1,115 910 705 560

1,950 1,705 1,535 1,485 1,370 1,065 855 635 475

NOTES: 1. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 2. Data is shown without filter. 3. Temperature rises in the table are approximate. Actual temperature rises may vary. 4. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 5. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 6. The "*" denotes the factory (default) COOL setting, "**" denotes the factory (default) HEAT setting, and "***" denotes the factory (default) FAN setting. If an alternate speed is to be used, refer to the installation instructions for Speed Tap Selection.

GENERAL TERMS OF LIMITED WARRANTY Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (05/2021)

628F-0521 (Replaces 628F-1020)

www.gibsonhvac.com

GIBSON is a pending or registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved.

Powered by TCPDF (www.tcpdf.org)


TCPDF 6.0.003 (http://www.tcpdf.org)