Mport3102 Mport3101 Mport3101-I Mport3104 Mport3102-I Mport3104-I Mport3101R Mport3102R Serial to Ethernet Server User Manual Version:V5.0 Please read this user manual carefully before using this product

Mport User Manual


File Info : application/pdf, 45 Pages, 9.93MB

PDF preview unavailable. Download the PDF instead.

1fs3c0a7aqn1qbab
Serial to Ethernet Server
User Manual
Mport3101 Mport3102 Mport3104 Mport3101-I Mport3102-I Mport3104-I Mport3101R Mport3102R
VersionV5.0 Please read this user manual carefully before using this product

Trademark
The trademark is owned by Wuhan Maiwe Communication Co., Ltd.
is the brand and registered by Wuhan Maiwe Communication Co., Ltd. Microsoft and Windows is registered trademark owned by Microsoft. Copyright © Wuhan Maiwe Communication Co., Ltd.
Clarification
The user manual is applicable to Mport3101/3101-I/3102/3102-I/3104/3104-I/3101R/ 3102R Serial Server. Please read the following license agreement carefully before using this manual. The products described in this manual can be used only if you agree on the following license agreement.
Important Statement
Any information provided by our company in this manual does not represent for corresponding authorization on these information. Our company attempts to ensure the accuracy and applicability for the information provided in this manual, however our company does not assume any responsibility for the use of these information, and does not assume any joint responsibility for the use of these information. There may be a few technical or typographical errors in the product and manual. The company reserves the right to change all or part of this manual without prior notice. Due to continuous update and improvement of products and technology, the contents of this document may not be completely consistent with the actual products, appreciate for your understanding. If necessary to inquiry the updates of the product, please check our official website or contact our representative directly.

Version V1.0 V2.0 V3.0 V4.0 V5.0

Date 2019.06 2020.06 2020.09 2021.01 2021.05

Reason Create File
Revise File Revise File Revise File Revise File

Safe Use Instructions
This product performance is excellent and reliable in the designed range of use, but it's necessary to avoid man-made damage or destroy for the equipment.  Read the manual carefully and keep this manual for reference if need afterwards.  Do not put the device close to the water sources or damp places.  Do not put anything on the power cable, it should be placed out of reach.  To avoid causing fire, do not knot or wrap the cable.  Power connector and other device connectors should be firmly connected with each other, frequently inspection is needed.  Please keep the fiber socket and plug clean. Do not look directly at the fiber section when the equipment is working.  Please keep the equipment clean and wipe it with a soft cotton cloth if necessary.  Please do not repair the equipment by yourself, unless there is clear instructions in the manual.
Under the following circumstances, please cut off power immediately and contact us.  Equipment water damage.  The equipment is broken or the casing is broken.  The equipment works abnormally or the performance has completely changed.  The equipment produces odor, smoke or noise.
Information requiring explanation in use of the managed software.
Statement
Attention Matters requiring specific attention in the use of the managed software.

MPort Series Unser Manual

Content

Chapter 1 Product Description.......................................................................4
1.1 Product Introduction..............................................................................................................4 1.2 Features .................................................................................................................................4 1.3 Product Display .....................................................................................................................5 1.4 Specifications.........................................................................................................................6 1.5 Interface and Indicator ......................................................................................................... 9 1.6 Product Size.........................................................................................................................13

Chapter 2 Software Quick Configuration......................................................15
2.1 Environmental Preparation ................................................................................................ 18
2.2 Log in Web ........................................................................................................................... 18 2.1.1 Revise IP adress...................................................................................................................... 18 2.1.2 Login in Web............................................................................................................................. 19
Chapter 3 Network Management Function...................................................21
3.1 Main Page Introduction ...................................................................................................... 21 3.1.1 Function menu ......................................................................................................................... 21 3.1.1 Help documentation................................................................................................................. 22 3.1.2 Basic information ..................................................................................................................... 23
3.2 Serial Port Configuration ....................................................................................................... 23 3.2.1 Serial port configuration ........................................................................................................... 23 3.2.2 Modbus function usage ............................................................................................................ 26 3.2.3 RealCOM function usage .......................................................................................................... 35 3.2.4 HttpdClient function usage ......................................................................................................... 36 3.2.5 WebSocketClient function usage ............................................................................................... 36
3.3 Serial Port Information ........................................................................................................... 37 3.3.1 Serial port information.............................................................................................................. 37
3.4 Network Address ...................................................................................................................38 3.4.1 Network address...................................................................................................................... 38
3.5 User Password ...................................................................................................................... 39 3.5.1 User password ........................................................................................................................ 39
3.6 System Information ................................................................................................................42
3.7 System Management ............................................................................................................. 42
Chapter 4 Maintenance and Service............................................................44
4.1 Internet service ...................................................................................................................... 44
4.2 Call the technical support office ............................................................................................. 44
4.3 Product repair or replacement................................................................................................44

MPort Series Unser Manual
Chapter 1 Product Description

1.1 Product Introduction
Mport3101/2/4 series industrial-grade serial server and Mport3101/2/4-I industrial-grade isolated serial server have the characteristics of anti-lightning, anti-electromagnetic interference, high reliability and high performance, and are suitable for use in harsh environments; Mport3101R/3102R industrialgrade rail-type serial server has the characteristics of small size and easy installation. The above-mentioned serial server mainly realizes data transmission between Ethernet and serial port (RS232/RS-485/RS-422). The TCP/IP protocol stack is integrated inside, and the device serial port can be flexibly configured as RS- 232 or RS-485 and RS-422 modes, so that RS-232/RS-485/RS-422 devices that cannot access the Internet can also be connected to the Ethernet easily, flexibly and quickly.
Mport3102-I/Mport3104/Mport3104-I only supports RS-485/RS-422 interface, not support RS-232.
Mport3101R/3102R only supports RS-485/RS-232, not RS-422 mode.

The specific models of this series of industrial serial server are as follows:

Mport3101

1 RS232/485/422 to Ethernet Desktop type Serial server(DC9~36V)

Mport3101-I

1 RS232/485/422 to Ethernet Isolated Desktop type serial server(DC9~36V)

Mport3102

1 RS232 + 1 RS485/422 to Ethernet desktop type serial server(DC9~36V)

Mport3102-I

2 RS485/422 to Ethernet Isolated Desktop type serial server(DC9~36V)

Mport3104

4 RS485/422 to Ethernet desktop type serial server(DC9~36V)

Mport3104-I

4 RS485/422 to Ethernet Isolated desktop type serial server(DC9~36V)

Mport3101R

1 RS232/485 to Ethernet Rail type serial server(DC5~36V)

Mport3102R
1.2 Features

2 RS232/485 to Ethernet Rail type serial server(DC9~36V)

High-performance CPU processing ability

 Adopt 32-bit Arm Cortex-M7 core CPU  Up to nearly 400MHz frequency

Industrial-grade surge protection

 Up to 6kV lightning protection on Ethernet interface  Mport3101/2/4 Series serial interface up to 2kV surge protection  Mport3101/2/4-I/Mport3101R/3102R Series serial interface up to 4kV surge protection

Industrial grade wide voltage power supply design  Provide industrial-grade DC power supply DC9~36V inputMport3101R supports DC5~36V input  With anti-reverse connection protection  Mport3101/2/4/2R Series up to 2kV surge protection  Mport3101/2/4-I Series up to 4kV surge protection

MPort Series Unser Manual
Isolated design(Only Mport3101/2/4-I isolated type support  Mport3101-I Isolation voltage 2KVDC, Mport3102/4-I Isolation voltage 3KVDC High reliability  External independent hardware watchdog design prevents crashes Industrial temperature design  Meet the industrial temperature range of -40~+85
1.3 Product Display

Mport3101R

Mport3101

Mport3101-I

5s INIT 1s RST

10/100M

Run Link Port1 Port2
Mport3102R
2 Ports Serial Device Server RS232/485 Ethernet

Port1

Port2

9~36V

A+ BTX RX G A+ BTX RX G V+ V-

Mport3102R

Mport3102

Mport3102-I

Mport3104

Mport3104-I

MPort Series Unser Manual
1.4 Specifications

Mport3101/2/4 Series

Model

Power Supply

Operating Voltage
Working Current

Network Port

Network Port
Isolation Protection Serial Ports

Baud rate

Serial Port

Data bit Stop bit

validation modes
ESD

Reliability

Surge

Other
Software Parameters

EFT
Size(L*W*H)
Working Environment
Storage Temperature
Network protocol
IP
DNS
User Configuration
Simple Transparent Transmission
Method
Modbus
Serial port packaging mechanism TCP Server Connection Network
Cache
Serial Buffer
Flow Control
Heartbeat Package Registration package
RFC2217
Average Transmission
Delay Supporting Software

Mport3101

Mport3102 9~36V

Mport3104

37mA@12V

39mA@12V

66mA@12V

10/100Mbps;RJ45 interface; adaptive MDI/MDIX cross-connect and auto-flip

1.5KV

1*RS-232/RS-485/422

1*RS-232+1*RS-485/422 600~460800bps 7, 8 1, 2

4*RS-485/422

none, odd parity, even parity

±6kV(contact); ±8kV(air) ±6kV(contact); ±15kV(air) ±8kV(contact); ±15kV(air) Power Supply: ±2kV/common mode, ±2kV/differential mode RS-485/422: ±2kV/common mode, ±2kV/differential mode

Network port:±6kV/ common mode, ±2kV/ differential mode

Power supply: ±2kV; Communication port: ± 2kV

96×90×26mm

207×112×34.2mm

-40+85, 5%95% RH (no condensation)

-40+85, 5%95% RH (no condensation)

IPv4, IP, TCP/UDP, ARP, ICMP, DHCP, DNS, HTTP, RFC2217 Static IP / DHCP Support Web configuration

TCP Server/TCP Client/UDP Client/UDP Multicast/RealCOM/PairConnection
Modbus RTU/ASCII to Modbus TCP Time and length can be set; the default value changes according to the bit rate; the
maximum packing length is 1460bytes. Support up to 8 TCP connections Send: 16Kbyte; Receive: 16Kbyte;
Send: 1.5Kbyte; Receive: 1.5Kbyte; Auto Flow Control TCP Keepalive
Custom registration package Support
<10ms
Network Configuration Tool, VirtualCOM, MWView, MaxView

MPort Series Unser Manual

Mport3101/2/4-I Isolation Series

Model

Mport3101-I

Operating

Power

Voltage

Supply

Working Current

83mA@12V

Mport3102-I 9~36V
78mA@12V

Mport3104-I 104mA@12V

Network Port

Network Port Isolation Protection
Serial Ports
Baud rate

10/100Mbps;RJ45 interface; adaptive MDI/MDIX cross-connect and auto-flip

1.5KV

1*RS-232/RS-485/422

2*RS-485/422 600~460800bps

4*RS-485/422

Data bit

7, 8

Serial Port

Stop bit
validation modes
Isolate Power Supply

2KVDC

1, 2 none, odd parity, even parity
3KVDC

ESD

±8kV(contact); ±15kV(air)

Power Supply: ±4kV/common mode, ±4kV/differential mode

Reliability

Surge

RS-485/422: ±4kV/common mode, ±4kV/differential mode

Network port:±6kV/ common mode, ±4kV/ differential mode

Other
Software Parameters

EFT
Size(L*W*H)
Working Environment
Storage Temperature
Network protocol
IP
DNS
User Configuration
Simple Transparent Transmission
Method
Modbus
Serial port packaging mechanism TCP Server Connection Network
Cache
Serial Buffer
Flow Control
Heartbeat Package Registration package
RFC2217
Average Transmission
Delay Supporting Software

Power supply: ±4kV; Communication port: ± 2kV

96×90×26mm

162×95×29mm

207×112×34.2mm

-40+85, 5%95% RH (no condensation)

-40+85, 5%95% RH (no condensation)

IPv4, IP, TCP/UDP, ARP, ICMP, DHCP, DNS, HTTP, RFC2217 Static IP / DHCP Support Web configuration

TCP Server/TCP Client/UDP Client/UDP Multicast/RealCOM/PairConnection
Modbus RTU/ASCII to Modbus TCP Time and length can be set; the default value changes according to the bit rate; the
maximum packing length is 1460bytes. Support up to 8 TCP connections Send: 16Kbyte; Receive: 16Kbyte;
Send: 1.5Kbyte; Receive: 1.5Kbyte; Auto Flow Control TCP Keepalive
Custom registration package Support
<10ms
Network Configuration Tool, VirtualCOM, MWView, MaxView

MPort Series Unser Manual Mport3101-R/3102-R Series

Model

Mport3101-R

Mport3102-R

Power Supply

Operating Voltage

5~36V

9~36V

Network Port

Network Port Isolation Protection

10/100Mbps; RJ45 interface; adaptive MDI/MDIX cross-connect and auto-flip 1.5KV

Serial Ports

1*RS-232/RS-485

2*RS-232/RS-485

Baud rate

600~460800bps

Serial Port

Data bit

7, 8

Stop bit

1, 2

validation modes

none, odd parity, even parity

EMC

Power Supply Network/Serial port

Anti-static, Surge protection Anti-static, Surge protection

Size(L*W*H)

87.5x36.5x58.6(mm

103x72.2x33.85(mm

Other

Working Environment -40+85, 5%95% RH (no condensation) -40+70, 5%95% RH (no condensation)

Storage Temperature -40+85, 5%95% RH (no condensation) -40+70, 5%95% RH (no condensation)

Network protocol

IPv4, IP, TCP/UDP, ARP, ICMP, DHCP, DNS, HTTP, RFC2217

IP

Static IP / DHCP

DNS

Support

User Configuration

Web configuration

Simple Transparent Transmission Method

TCP Server/TCP Client/UDP Client/UDP Multicast/RealCOM/Pair Connection

Modbus

Modbus RTU/ASCII to Modbus TCP

Serial port packaging mechanism

Time and length can be set; the default value changes according to the bit rate; the maximum packing length is 1460bytes.

TCP Server Connection

Support up to 8 TCP connections

Software Parameters

Network Cache Serial Buffer

Send: 16Kbyte; Receive: 16Kbyte; Send: 1.5Kbyte; Receive: 1.5Kbyte;

Flow Control

Auto Flow Control

Heartbeat Package

TCP Keepalive

Registration package

Custom registration package

RFC2217

Support

Httpd Client

Support

RealCOM
Average Transmission Delay
Supporting Software

Supports working modes such as Maiwe, Moxa, Kanghai, etc. <10ms
Network Configuration Tool, VirtualCOM,MWView, MaxView

MPort Series Unser Manual
1.5 Interface and Indicator lights
Desktop serial server takes Mport3101 as an example.
RJ45

Reset

Power RS232

Indicate Lights

RS-485/422
Mport3101R

RS232/485

Mport3102R

5s INIT 1s RST

10/100M

Power

Indicate Lights
Reset

Run Link Port1 Port2
Mport3102R
2 Ports Serial Device Server RS232/485 Ethernet

Port1

Port2

9~36V

A+ BTX RX G A+ BTX RX G V+ V-

RS232/485 Power

Reset

Restart/restore factory settings button
Press and release the button within 1 second, the system resets, the Run light goes out, and the system returns to normal after startup;
Press for more than 5 seconds, the Run light flashes stroboscopically (flashing once for 0.2s), release the button at this time, the parameters will be restored to the factory settings, and the system will be reset.

MPort Series Unser Manual
Ethernet RJ45 interface
The 10Base-T/100Base-TX adaptive Ethernet RJ45 interface supports automatic MDI/MDI-X connection; refer to the figure below for the pin distribution of the RJ45 interface. Mport3101R adopts RJ45 interface without light, as shown in the left picture below; other serial server adopts RJ45 interface with light, as shown in the right picture below.

1 23456 7 8 Pin number
1 2 3 6 4, 5, 7, 8

8 765432 1 Signal name
Send data+ (TD+) Send data -(TD-) Receive data+ (RD+) Receive data- (RD-)
Unused

Power connector Mport3101R only supports 2P terminal sub, voltage input range: DC 5~36V; Mport3102R only supports 14P terminal sub-power supply, voltage input range: DC 9~36V; Other products support two connection modes: DC connector (2.5mm) and 2P terminal sub (5.08mm pitch), with voltage input range: DC 9~36V.

+-

DC(2.5mm)

Terminal blocks(5.08mm)

14PTerminal blocks

RS-485/RS-422Serial interfaceExcept Mport3101R, Mport3101R is RS-232/RS-485 interface
The RS-485/RS-422 interface uses 5-bit 5.08mm pitch terminal blocks; refer to the following figure for pin assignments of various interfaces:

A B Unused GND

T+ T- R+ R- GND

1 2 3 4 5

1 2 3 4 5 RS485

1 2 3 4 5 RS232

MPort Series Unser Manual
RS-232/RS-485 serial interface (only Mport3101R/3102R with this kind of interface)
The RS-232/RS-485 interface adopts 5-bit 5.08mm pitch terminal blocks, please refer to the figure below for the pin assignment of various interfaces)

TX RX GND

1 2 3 4 5

GND A+ B-

1 234 5

1 234 5

Mport3102R is equipped with RS232/485 interface (using 14-bit 3.5mm pitch terminal sub); refer to the following figure for the pin assignment of various interfaces:

1 2 3 4 5 6 7 8 9 10 11 12 13 14

TX RX GND

TX RX GND

V+ V-

A+ B-

AG+NDB-

GND V+ V-

1 2 3 4 5 6 7 8 9 10 11 12 13 14
RS232

1 2 3 4 5 6 7 8 9 10 11 12 13 14
RS485

RS-232 Serial interface
RS-232 interface adopts DB9 male header (except Mport3101R); refer to the following figure for interface pin assignment:

MPort Series Unser Manual

Pin number

Pin name

1

2

RXD

3

TXD

4

5

GND

6

7

8

Indicator lights

Pin description

Signal level

None Receive Data Transmit Data
None Ground
None None None

RS-232 RS-232
Ground

direction
Input Output Ground

Indicator light
PWR
Run
TX
RX TX/RX (Mport3102/Mport3101R
Yellow light on the left side of the network port
Green light on the right side of Link&Network port
Port1/Port2 (Mport3101R/3102R)

status
On Off Flash On, Off Flash Off Flash Off Flash Off On Off Flash On Off Flash Off

definition
Power supply is normal
No power supply or abnormal power supply Equipment in normal operation
The equipment is operating abnormally The RS-232/RS-485/RS-422 interface is sending data
no data The RS-232/RS-485/RS-422 interface is receiving data
no data The RS-232/RS-485/RS-422 interface is sending and
receiving data no data
Connect to a 100M network at this time
Connect to a 10M network at this time The network port is connected normally and there is
data transmission The connection is normal and there is no data
transmission Abnormal connection
The RS232/485 interface is receiving and sending data no data

MPort Series Unser Manual
1.6 Product Size
22 8 12.5 96 11 12.5 8 22

21.5

8

12.5

95

11

12.5 8

21.5

66

26

4
4 6.5
6.5

80 90
Mport3101/3101-I/3102 size (mm)

138

29

4 4
6.5 6.5

152 162
Mport3102-I size (mm)

MPort Series Unser Manual
38 11 112 14 11 38

207 185
33
4
6 15
34.2 192
Mport3104/3104-I size (mm)

Mport3101R size (mm)

MPort Series Unser Manual

72,20

33,85

103
Mport3102R size (mm)

MPort Series Unser Manual
Chapter 2 Software Quick Configuration
MAIWE MPort series serial server has a built-in Web server, which provides a convenient way to access and configure the serial server. Users can use IE, Firefox or Google browser to access it.
This chapter is a quick introduction to the MPort series of serial server products. It is recommended that users read this chapter and follow the instructions once for the system, and they will have a basic understanding of the product. For specific function details and instructions, please refer to the subsequent chapters.
If you need product-related information, you can download the corresponding product manual from the official website link: http://www.maiwe.com.
Figure1 MAIWE Global Site Page

MPort Series Unser Manual
2.1 Environmental Preparation
For fast networking of MPort series serial server, you need to prepare a PC, a serial server, a network cable, a serial cable, and a DC12V/1A power supply. The hardware connection is shown in Figure 2.

2

2.2 Log in Web

Figure 2 Hardware Connection

2.1.1 Revise IP adress
When accessing the Mport serial server through the Web, the IP address of the serial server and the PC must be in the same network segment, so the IP address of the PC must be modified to ensure that it is in the same local area network as the IP of the serial server. For Windows users, please refer to the following operations:
StartControl PanelNetwork and Internet ConnectionNetwork ConnectionLocal ConnectionPropertiesInternet Protocol (TCP/IP) The default IP address of this model of serial server is: 192.168.16.253. Set the PC's IP address as: 192.168.16.X (X is any valid value from 2 to 253 except 253). The specific Windows system operation page is shown in Figure 3.

Figure 3 IP setting interface under Windows environment

MPort Series Unser Manual
After changing the IP address of the PC, you can access the Web page of the Mport series serial server through the default IP address 192.168.16.253, and perform related configuration operations on it.
2.1.2 Login in Web
Open the browser and enter the default IP address of the serial server in the address bar, as shown in Figure 4.
Figure 4 Enter the IP address interface in the address bar
After hitting the Enter key, the window shown in Figure 5 pops up, prompting the user to enter the user name and password.
Figure 5 Input user name and password interface
The login users of this MPort series serial server are divided into three types. The first is a normal user, the user name and initial password are both "admin", it is used when accessing the Web normally; the second is a guest, the user name and password are both "none", after logging in, only the configuration of the current serial server can be viewed, And can't be configured; the third type is the administrator, the user name is "admin", and the password is the last six digits of the serial server's MAC address. When we forget the password of an ordinary user, we can log in with the administrator account and modify this Machine password.
After entering the user name and password, click "OK" and the server will authenticate. After success, you will enter the main page of the Web server, as shown in Figure 6.

MPort Series Unser Manual
Figure 6 The main interface of the Web server
This MPort series serial server has been tested extensively with IE7.0 or higher, Firefox, and Google's mainstream browsers, and it can be used normally, but it is recommended to use Google browser when upgrading the device.

MPort Series Unser Manual
Chapter 3 Network Management Function
3.1 Main Page Introduction
After entering the correct user name and password and the authentication is successful, you will enter the main page of the Web, as shown in Figure 7. The main page can be roughly divided into three areas. The upper area displays the logo, the lower left area is the function menu area, the middle area is the main function display area, and the lower right area is the help document area.
Figure 7 The main interface of the Web server
3.1.1 Function menu
The left side of the webpage is the function menu area, which displays all the configurable software functions of this Mport series serial server. The function menus are basic information, serial port, serial port information, network address, user password, system information and system management. Each function menu contains several sub-functions. Its function is shown in Table 1.

MPort Series Unser Manual

Table 1 Menu function description table

Basic information
Serial port configuration
Serial port information Website address

Device

Display device information, such as: name, number,

Information software version, IP address, etc.

Serial server Configure the basic information of each port, such as:

configuration serial port number.

Serial port Configure the working mode, baud rate, packet length, etc.

parameters of each port.

Network Configure the local port range and heartbeat interval of

parameters each port.

Number of network
connections

Configure the destination address and remote port of each port.

Serial port Display the serial port number and the total number of

information serial ports received and sent.

Network Display the working mode of the serial port/local port and

connection mode other information.

Website

address

Configure the IP address, subnet gateway for serial communication.

mask

and

default

User password System info

User password Configure username and password.

system info

Configure the device model, device name, etc. of the device.

Device restart Configure the restart function of the device.

Factory reset of the device

Configure the device to restore factory values.

System management

Equipment upgrade

Configure the upgrade file of the device.

No data device restart

The network and serial port of the configuration device have no data transmission for a certain period of time, and the device restarts.

3.1.1 Help documentation
The function area at the bottom right is the help document. Click any main function page in the lower left, and the help document will be displayed in the lower right function area corresponding to the main page, as shown in Figure 8.

Figure 8 Help Page

MPort Series Unser Manual
3.1.2 Basic information
The basic information module includes: device information. The function of the device information part is to display some specific information of the current device, including device model, device name, device number, system time, hardware version, software version, IP address and MAC address. As shown in Figure 9.
Figure 9 Device information
 Device model: The model of the serial server, which can be customized by the user on the "System Information" page.  Device name: The name of the serial server, which can be customized by the user on the "System Information" page.  Device number: the serial port server number.  System time: The current time of the serial server is synchronized with the time of the PC accessing the serial server.  Hardware version: the current hardware version of the serial server.  Software version: the current software version of the serial server.  IP address: the IP address of the serial server.  MAC address: the MAC address of the serial server.
3.2 Serial Port Configuration
The serial port module includes: serial server configuration, serial port parameter configuration, network parameter configuration, network connection number configuration.
3.2.1 Serial port configuration
The main function of the serial Ethernet server is to carry out two-way transparent transmission of standard serial bus data (RS-232, RS-485, RS-422) and standard Ethernet data supporting TCP/IP protocol to solve common serial equipment Networking problems on the Internet. The serial server configuration page can configure the parameters of the serial Ethernet server, as shown in Figure 10.

MPort Series Unser Manual

Figure 10 Serial port configuration page

The detailed description of the configuration parameters on this interface is shown in Table 2.
Table 2 Description of serial port server configuration parameters

Item

Instruction

Serial port number

Select the serial port currently to be configured, enable or disable it. Mport3101/3101-I/Mport3101R supports 1 serial port; Mport3102/3102-I supports 2 serial ports; Mport3104/3104-I supports 4 serial ports.

Turn on large dataAccording to the amount of data transferred and the connection mode,

transmission

choose to enable or disable it

Serial port parameters

Select the mode of the current serialization;

Mport3101 chooses RS232/485/422 functions separately according to needs;

Mport3101-I is a RS232/485/422 three-in-one device, you don't need to

choose it when you use it, just use it directly according to your needs;

Serial port workingMport3102 Port 1 supports RS485/422, Port 2 supports RS232;

mode

The two serial modes of Mport3102-I are both RS485/422;

Mport3104/3104-I 4-channel serial mode is RS485/422;

Mport3101R/Mport3102R supports RS485/232 mode, only one can be se-

lected.

Baud rate
Check Digit Data bit

The baud rate of serial communication, the unit is bps; the options are: 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 and 460800. The factory default value is 9600. The baud rate of each serial port is independent of each other, set separately, and does not affect each other. (Mport3101 supports up to 19200bps in Modbus ASCII mode) Select the check mode, there are three modes to choose from: none, odd check, and even check. The factory default setting is none. The verification mode of each serial port is also independent of each other, set separately, and does not affect each other. Set the effective number of data bits during serial communication. This machine supports 7-bit and 8-bit data bits.

MPort Series Unser Manual

Stop bit

Set the stop bit length in serial communication, you can choose: 1, 2. The factory default setting is 1

When the serial port continuously receives data whose length exceeds the value set by

Packet length

the packet length, a transmission operation will be triggered, and the data will be forwarded to the network port. The value ranges from 1 to 1460 bytes.

When the intermittent time of serial port receiving data exceeds this value, no matter

Packet interval

how much data has been received, a transmission operation will be triggered, and these

data will be forwarded to the network port, the range is 1~65535ms

Frame header and footer mode

After enabling this mode, the serial port will be packetized according to the frame start byte and end byte, and the data not between the head and tail will be discarded

Start byte

Set the range of the starting byte of the serial port to be between 0x00~0xff in hexadecimal

End byte

Set the range of the end byte of the serial port to be between 0x00 and 0xff in hexadecimal

Registration package function

Choose the sending mode of the registration package Disable: Disables the function LINK: The registration packet is sent only once when the network connection is established DATA: The registration package is filled in front of the serial port DATA each time the serial port sends DATA to the network This function can be used only when the network working mode is UDP or TCP Client

Registration Package Contents

The content of the registration package, Hex string, the longest supported is 128 bytes (hexadecimal is 64 bytes)

Heartbeat Packet Function

Choose how to send heartbeat packets Disable: Disable this feature to COM: Heartbeat packets are sent to the serial port to Network: Heartbeat packets are sent to the network port This function is only allowed when the network working mode is UDP, TCP Server and TCP Client

The content of the heartbeat packet, Hex string, the longest supported is 128 bytes Heartbeat package content
(hexadecimal is 64 bytes)

Heartbeat interval

The time interval for sending heartbeat packets, in seconds, the range is 1~65535 seconds, the default is 30 seconds

Enabling this function allows users to dynamically modify parameters such as baud rate,

RFC2217

data bits, stop bits and parity bits of the serial port using standard RFC2217 commands on the network

MPort Series Unser Manual Working mode

Network parameters UDP, UDP Multicast, TCP_Client, TCP_Server Modbus_RTU_Master, Modbus_RTU_Slave, Modbus_ASCII_Master, Modbus_ASCII_Slave, RealCOM MCP, RealCOM CCP ten ways to choose from. Factory default setting is UDP mode When the working mode of the device is UDP, it is required that the remote device must also work in the UDP mode. The device can establish UDP connections with up to 4 remote devices, and the IP address and port number of the remote devices can be configured on the page When the working mode of the device is UDP Multicast, it is required that the remote device must work in the UDP Multicast mode. The device can join up to 4 UDP multicast groups, and the multicast IP address and port number can be configured on the page When the working mode of the device is TCP_Client, it is required that the remote device must work in TCP_Server mode, and its IP address and port number must be configured, which can be configured in the options corresponding to the network connection. The local port number can be ignored without configuration When the working mode of this device is TCP_Server, it is required that the remote device must work in TCP_Client mode. In this mode, up to 8 remote TCP_Client connections are accepted When the working mode of the device is Modbus_RTU_Master, if the Modbus Over TCP function is not enabled, the remote device must work in the Modbus_TCP_Slave mode; otherwise, if the Modbus Over TCP function is enabled, the remote device must work in the Modbus_RTU_Slave mode. This mode supports up to 4 connections When the working mode of the device is Modbus_RTU_Slave, if the Modbus Over TCP function is not enabled, the remote device must work in the Modbus_TCP_Master mode; otherwise, if the Modbus Over TCP function is enabled, the remote device must work in the Modbus_RTU_Master mode. This mode supports up to 8 connections When the working mode of the device is Modbus_ASCII_Master, if the Modbus Over TCP function is not enabled, the remote device must work in the Modbus_TCP_Slave mode; otherwise, if the Modbus Over TCP function is enabled, the remote device must work in the Modbus_ASCII_Slave mode. This mode supports up to 4 connections When the working mode of the device is Modbus_ASCII_Slave, if the Modbus Over TCP function is not enabled, the remote device must work in the Modbus_TCP_Master mode; otherwise, if the Modbus Over TCP function is enabled, the remote device must work in the Modbus_ASCII_Master mode. This mode supports up to 8 connections When the working mode of the device is RealCOM MCP or RealCOM CCP, the PC needs to install the corresponding virtual serial port software for use. The virtual serial port software maps the serial port of the remote serial port server to the local serial port, so as to realize the transparent communication between the original serial port software and the serial port of the serial port server. One serial port of the serial server supports up to 8 virtual serial ports for access

MPort Series Unser Manual

Local port

Local port on the network connection side

When the network working mode is in TCP mode, send TCP heartbeat detection packets

Heartbeat interval

at the specified interval to test whether the connection exists, if not, it will automatically

disconnect, the range is 0~6000 seconds

When the network working mode is in TCP mode, it will detect the idle time of the current

Overtime time

connection and the corresponding serial port. When it exceeds the set value, the TCP

connection will be disconnected.

Modbus Over TCP

Modbus (s RTU/ASCII) protocol transparent transmission enable

Modbus receive timeout Modbus serial port receive timeout time

Modbus ID filtering

Modbus slave ID range filtering

The serial port server automatically performs pre-reading according to the configuration Mo pre-db read us from slave
in the Modbus pre-reading instruction table, and supports up to 8 items

When M polls od to poll bu, s The interval time when the serial server reads each item according to the pre-reading

slave machine

instruction table

Destination address Destination port

Number of network connections IP address of the peer end of the network connection The port number of the peer end of the network connection Number of network connections in Modbus_RTU/ASCII_Master mode

Destination address

IP address of the peer end of the network connection

Destination port Modbus ID range
Device address Instruction Register address Number of registers

The port number of the peer end of the network connection The data with the Modbus slave ID in this range will be forwarded to the corresponding destination network address Modbus_RTU/ASCII_Slave mode Modbus pre-read command table Modbus slave ID Modbus function code for reading data The starting address of the slave register to be read Number of slave registers to read

3.2.2 Modbus function usage
Take MPort3101-I as an example below, other models are similar. Simulate the master with software such as Modbus Poll, and simulate the slave with software such as Modbus Slave.

MPort Series Unser Manual
3.2.2.1 Modbus Master Take Modbus_RTU_Master as an example (Modbus ASCII Master is the same): Configure the "serial port parameter" of the serial server to 9600-8-N-1, the working mode in"network parameters" is Modbus RTU Master, and the network address in "Network Connections" is configured as the IP and port of the slave. The physical connection is described as follows:
 Serial port: connect to the host  Network port: connect to the slave
Figure 11 Modbus Web parameter configuration
Modbus Poll software configuration: Open the Modbus Poll software, go to "Connect" -> "Connect", and the connection parameters are configured as follows:
Figure 12 Modbus host serial port parameter configuration

MPort Series Unser Manual
Read parameter configuration: the slave ID is 1, the function code is 03, the starting address of the register to be read is 0, the number of registers to be read is 10, and the cycle reading interval is 1000ms.
Figure 13 Modbus host device attribute definition
Open Modbus Slave software: Go to "Connect" -> "Connect", and the connection parameters are configured as follows:
Figure 14 Mosbus slave network connection configuration

MPort Series Unser Manual
Slave device definition configuration: the slave ID is 1, the function code is 03, the register start address is 0, and the total number of registers is 200.
Figure 15 Mosbus slave device attribute definition
Double-click the cell of Modbus Slave software and modify it to auto-increment mode, you can see that the register cell of Modbus Poll software also changes value automatically. Indicates that the device communication is normal.
Figure 16 The value of Modbus slave register is automatically incremented

MPort Series Unser Manual
Figure 17 Communication is normal, the host can read the register data of the slave through the serial server device
3.2.2.2 Modbus Slave Take Modbus_RTU_Slave as an example (the same applies to Modbus ASCII Slave): Configure the "serial port parameter" of the serial server to be 9600-8-N-1, the working mode in the
"network parameter" is Modbus RTU Slave, and the local port is 502. The physical connection is described as follows:  Network port: connect to the host  Serial port: connect to the slave

MPort Series Unser Manual Figure 18 Modbus Web parameter configuration

MPort Series Unser Manual
Open Modbus Poll software: Go to "Connect" -> "Connect", and the connection parameters are configured as follows:
Figure 19 Modbus host network connection parameter configuration
Read parameter configuration: the slave ID is 1, the function code is 03, the starting address of the register to be read is 0, the number of registers to be read is 10, and the cycle reading interval is 1000ms.
Figure 20 Modbus host device attribute definition

MPort Series Unser Manual
Open Modbus Slave software: Go to "Connect" -> "Connect", and the connection parameters are configured as follows:
Figure 21 Modbus slave serial port parameter configuration
Slave device definition configuration: the slave ID is 1, the function code is 03, the register start address is 0, and the total number of registers is 200.
Figure 22 Modbus slave device attribute definition

MPort Series Unser Manual
Double-click the cell of Modbus Slave software and modify it to auto-increment mode, you can see that the register cell of Modbus Poll software also changes value automatically. Indicates that the device communication is normal.
Figure 23 Modbus slave register value auto increment
Figure 24 The communication is normal, the host can read the register data of the slave through the serial server device

MPort Series Unser Manual
1. The port numbers 57050 and 57051 have been used by the system. When configuring the port numbers, please do not reuse them. 2. The device and the remote device must have the same baud rate, parity bit, data bit and stop bit. 3. If the working mode of the device is UDP, the remote device must also work in UDP mode; if the working mode of the device is TCP_Client, the remote device must work in TCP_Server mode; if the working mode of the device is TCP_Server, the remote device must work in In TCP_Client mode. 4. When you need to use long frame data frequently or have high data transmission requirements, please adjust the baud rate and lengthen the sending interval appropriately to prevent the slow serial port from causing messy codes or packet loss. 5. When configuring the device, the user should ensure that the external RS-232/RS485/RS-422 device stops sending data to the serial server to avoid garbled characters. 6. When Modbus_ASCII_Master turns on the transparent transmission mode, it only supports reading of up to 60 registers. 7. Mport3101 is affected by the hardware configuration, Modbus ASCII protocol transmission only supports use below 19200 baud rate.
3.3.3 RealCOM function usage
In RealCOM mode, the serial server cooperates with the operating system installed with RealCOM driver software. The RealCOM driver software maps the serial server's serial port to the host's local COM interface, so that the original serial device software or communication module on the host can be used directly without modification. The RealCOM driver software transparently transmits the data received by the virtual COM interface on the host to the serial server in the form of TCP/IP. The serial server transparently transmits the data received from the serial port to the virtual COM interface of the host computer in the form of TCP/IP.
The serial server supports three RealCOM protocols: RealCOM_MCP mode is compatible with Moxa's drive management software; RealCOM_CCP mode is compatible with Kang Hai's serial management tool; RealCOM_MW mode supports Maiwe's MWVirtualCOM software.
How to use Maiwe RealCOM: 1. The WEB of the serial server is configured as RealCOM_MW mode; 2. Install and open Maiwei virtual string management software; 3. Click [Add Device], and the add serial mapping interface will pop up; 4. Click [Scan], the software will scan the serial server devices in the local area; 5. According to the MAC address and IP address, select the corresponding serial server device; 6. Click [String Mapping] and wait for the creation of a local virtual string; 7. Connect the string of the serial server with the real string on the host, and use the string debugging tool to open the string created by the virtual string management software and the real string on the host, one of the two Send data to each other for testing.
3.3.3 Httpd Client function usage
This function is that the serial server submits the data received by the serial to the HTTP server in the form of HTTP. If the HTTP server has data to be sent, the string server will transparently transmit the data of the HTTP body to the string.
Specific usage method:
1. Select "Httpd Client" as the work mode;

MPort Series Unser Manual
2. Fill in the HTTPD address, that is, the address of the HTTP server, which can be an IP address or a domain name (the ability to connect to foreign countries is required); 3. Fill in the HTTPD port number; 4. The HTTPD method needs to fill in the correct URL path, and select the GET or POST method as needed; 5. Fill in the HTTPD request header as needed; 6. Finally, click the Configure button to save the parameters.
Figure 25 Httpd Client communication Wireshark packet capture example
3.3.3 WebSocketClient function usage
This function is that the serial server acts as a WebSocket Client, and transparently transmits the data received by the serial to the WebSocket server in hexadecimal format. The WebSocket server can also send data to the serial device at any time.
Specific usage method: 
1. Select "WebSocket Client" as the work mode; 2. Fill in the WebSocket server address, which can be an IP address or a domain name (you need to have the ability to connect to the outside world); 3. Fill in the WebSocket server port number; 4. WebSocket method needs to fill in the correct URL path; 5. You can select the WebSocket Ping time interval according to your needs, fill in 0 to indicate not to use the Ping function; 6. Finally click Configure button to save parameters.
Figure 26 WebSocletClient communication Wireshark packet capture example

MPort Series Unser Manual 

1. The port number 80, 4500, 4800, 57050, 57851, 57850, 57851 has been used by

the system. When configuring the port number, please

Do not use repeatedly.

2. The device and the remote device must have the same baud rate, parity bit, data bit

and stop bit;

3. If the operation mode of this device is UDP, the remote device must also operate in

UDP mode; if the operation mode of this device is TCP_Client, the

remote device must operate in TCP_Server mode; if the device operates The mode is



TCP_Server, and the remote device must work in TCP_Client mode. 4. If the operation mode of this device is UDP multicast mode, the same multicast ad-

dress can only be used once, and no multicast address is allowed.

The address is used in different serial configurations.

5. When you need to use frame data frequently or have high requirements for data



transmission, please adjust the baud rate and the sending interval appropriately. The slower anti-crossover speed causes garbled characters or packet loss. 6. When configuring the device, make sure that the external RS232/485/422 device

stops sending data to the serial server to avoid garbled characters.

7. When Modbus_ASCII_Master turns on the transparent transmission mode, it only

supports reading of 60 registers at most.

8. Mport3101 is affected by the hardware configuration, Modbus ASCII protocol trans-

mission only supports the use below 19200 baud rate.

9. Affected by the serial rate, when Modbus data timeout occurs, the web should be

configured with appropriate modbus receiving timeout

At the same time, the read timeout time of the host computer should be appropriately

extended according to the baud rate.

10. To use the RealCOM function, the firmware version of the serial server must be

V1.x.9.210512 and above, and the software version of the virtual serial tool must be

V1.0.300.05 and above.

3.3 Serial Port Information The serial port information module includes two parts: serial port information and network connection information.

3.3.1 Serial port information
The serial port information page is used to display the current connection information of the serial port as shown in Figure 27:

Figure 27 Serial port information page

MPort Series Unser Manual
3.4 Network Address
The network address module includes: the IP address of the network, the subnet mask, and the default gateway.
3.4.1 Network address
The function of this function is to assign a designated IP address to the Mport series serial server. The default IP address of the serial server when it leaves the factory is 192.168.16.253. The network address configuration page is shown in Figure 28.
Figure 28 Network address interface
 Network protocol: select static address or DHCP.  IP address: IP address is a 32-bit address assigned to devices connected to the Internet. The IP address consists of two fields: the network number field (Net-id) and host number field (host-id). The IP address is assigned by the Network Information Center (NIC) of the US National Defense Data Network. In order to facilitate the management of IP addresses,IP addresses are divided into five categories: Class A, B, and C addresses are unicast addresses; Class D addresses are multicast addresses; Class E addresses are reserved addresses for future special purposes. The IP addresses currently in large numbers belong to three types of addresses: A, B, and C.  Subnet mask: The mask is a 32-bit number corresponding to an IP address. Some of these numbers are 1, and the others are 0. The mask can divide the IP address into two parts: the subnet address and the host address. The part of the IP address corresponding to the 1 bit in the mask is the subnet address, and the other bits are the host address. The mask for class A addresses is 255.0.0.0; the mask for class B addresses is 255.255.0.0; the mask for class C addresses is 255.255.255.0.  Default gateway: The default gateway in the host is usually called the default route. The default route (Default route) is the route chosen by the router when no other route exists for the destination address in the IP packet. All packets whose destination is not in the router's routing table will use the default route. This route usually connects to another router, and this router also processes data packets. If you know how to route this data packet, the data packet will be forwarded to a known route; otherwise, the data packet will be forwarded to the default Routing to reach another router.  DNS: The IP address of the DNS server. When the device uses a static IP address, the user is required to fill in this item. If a specific DNS server is not used, the default gateway IP address is generally sufficient. Whenever users modify the address settings, they need to click the button to submit to the Mport series serial server and switch to a waiting page as shown in Figure 29.

MPort Series Unser Manual
Figure 29 The waiting interface diagram after the user modifies the address
When the progress bar in the screen is finished, the Mport series serial server restarts the Web server, and the user needs to log in again.
1. When entering the waiting page after configuring the IP, do not power off or perform other operations to avoid failure of the IP address modification. 2. The configured IP address and the default gateway must be in the same network segment. 3. If the device uses DHCP to obtain an IP address, after the device restarts, the user needs to use the company's network management assistant to search for the device to accurately know the new IP address of the device.
3.5 User Password
The user password module is mainly used to modify the password.
3.5.1 User password
The Web server of this Mport series serial server provides users with three different permissions. The first type is for visitors, which can only view the current various configurations of the serial server, but cannot modify the configuration. The user name and password are both "none" and cannot be modified; the second is for ordinary users, which can configure various functional parameters of the serial server. The user name is admin and cannot be modified. The initial password is "admin", which can be modified on this page; the third is the administrator, the account has the highest authority, and when the password of a common user is forgotten, the administrator can log in and modify it The password of this machine, the user name is fixed as "admin", and the password is the last six digits of the machine's MAC address. (If you don't know the MAC address of the machine, you can log in as a guest to view it first).
The login password must be legal characters, consisting of 4-12 English letters (case sensitive) and numbers. When changing the password, you need to enter it twice, and you must ensure that the passwords entered twice are consistent. The page is shown in Figure 30.

MPort Series Unser Manual
Figure 30 User password interface
 User name: The user name of this machine is fixed as "admin" and cannot be modified.  New password: Set the user password of this group, consisting of 4-12 English letters (case sensitive) and
numbers.  New password confirmation: Repeat the password to prevent entering the password incorrectly.

MPort Series Unser Manual
1. The passwords of ordinary users are modified on this page. 2. For security, it is recommended to change the default password after logging in
for the first time.
3.6 System Information
The model, name, and number of the device can be configured on the system information page, as shown in Figure 31.
Figure 31 System Information Interface
 Device model: Users can customize the model of the Mport series serial server.  Device name: The user can customize the name of the Mport series serial server.  Device platform: the name of the manufacturer's platform, which cannot be configured by the user.  Device Number: The serial number of the serial server is not configurable by the user.
3.7 System Management
This page can perform some system operations on the Mport series serial server, including restarting, restoring factory configuration, and upgrading. It is recommended that users use it with caution. Improper operation may damage the serial server. The page is shown in Figure 32.
Figure 32 System Management Interface
 Device restart: This function is used to restart the Mport series serial server by software. Before the serial server is completely restarted, the device does not work and cannot forward any data packets. This restart is different from the hardware reset of power-on restart, but the serial server system software is reset, just like the "warm restart" of the windows operating system. The biggest advantage of this function is to

MPort Series Unser Manual
provide a function of remotely restarting the serial server. As long as the user can access the serial server remotely, it can be restarted remotely. Click on "Start" Button, the page pops up a prompt box, as shown in Figure 33, click "OK" to jump to the waiting page, after the progress bar in the page is read, the serial server restarts to complete.
Warning: The system will restart! Please confirm whether to perform this operation?

OK

NO

Figure 33 Warning message of device restart
 Restore the factory settings of the device: This function is used to restore the Mport serial server to the factory settings and automatically restart the serial server at the same time. Before the serial server restarts successfully, the serial server does not work and cannot forward any data packets. This function is to restore the factory default configuration value once the user sets the wrong parameter and causes the serial port server to work abnormally. There is the option of "Keep the current IP address" on the right. When checked, the current IP address will be retained. If not checked, the IP address will also be restored to the factory default address: 192.168.16.253. Click the "Start" button, and a prompt box will pop up on the page, as shown in Figure 34. Click "OK" to jump to the waiting page. After the progress bar in the page is read, the serial port server is restored to its factory configuration.

Warning: Restoring the factory configuration will cause the previous configuration of the device to be overwritten. If you do not check "Keep current IP address", the IP address will be restored to the default address 192.168.16.253 when the device is shipped from the factory. Please confirm whether to perform this operation?

OK

NO

Figure 34 The warning message when the device is restored to factory configuration
 Device upgrade: This function is used to upgrade the software of the Mport series serial server. Users can get the upgrade program of the serial server through email or our company's website. Please pay attention to the matching of the device model and version, and use the unmatched upgrade program Will cause the upgrade to fail. After the user gets the upgrade program, click `'Browser".
Click the "Start" button to select the upgrade program, and then click the button, the page pops up a prompt box, as shown in Figure 35, click "OK" to jump to the waiting page, after the progress bar in the page is read, the serial server software upgrade is completed.

MPort Series Unser Manual
Warning: Please do not cut off the power of the device or interrupt the network connection with the device during the firmware upgrade process, the device will restart after the upgrade is completed. Please confirm whether to perform this operation?

OK

NO

Figure 35 Warning message of equipment system upgrade
 Device restart without data: This function is used for the serial port server of the Mport serial server without any data transmission or reception for a long time, and the serial server automatically restarts. If the restart time is set between 0 and 59 seconds, this function does not take effect. Only when the time is set to be greater than or equal to 60 seconds, the restart function of the device without data will take effect. The default value is 3600s, which is one hour.

1. Restoring the factory settings will cause all the settings to be restored to the state just left. If you want to keep the IP, please check the "Retain the current IP address" on the right, otherwise the IP address will also be restored to the default configuration 192.168.16.253. 2. Do not upgrade the device casually. When the device needs to be upgraded, you must make sure that the upgrade file is correct, otherwise it is easy to damage the software of the device and cause the Mport series serial server to malfunction. 3. Please do not operate the Mport serial server during the upgrade process, and it is forbidden to click on the serial server web page. If the upgrade is interrupted due to misoperation, please restart the serial server and try again. 4. Power failure is not allowed during the entire upgrade process. Power failure may cause permanent damage to the Mport series serial server. If the power is interrupted during the upgrade, please mail the product to our company immediately for possible solutions. 5. To set restart parameters for devices with no data, avoid using the Chrome 68 version of Google Chrome, otherwise there will be a problem that the configuration page cannot respond.

MPort Series Unser Manual
Chapter 4 Maintenance and Service
From the date of product shipment, Wuhan Maiwe Communication Co., Ltd. provides a five-year product warranty. According to the product specifications of Wuhan Maiwe Communication Co., Ltd., during the warranty period, if the product has any malfunction or functional operation failure, Wuhan Maiwe Communication Co., Ltd. will repair or replace the product for the user free of charge. However, the above commitment does not cover damage caused by improper use, accidents, natural disasters, incorrect operation or incorrect installation. In order to ensure that consumers benefit from the series of products of Wuhan Maiwe Communication Co., Ltd., help and problem solving can be obtained through the following methods:
Internet service Call the technical support office Product repair or replacement
4.1 Internet service
Through the technical support section of Wuhan Maiwe Communication Co., Ltd. website, you can get more useful information and usage skills.
4.2 Call the technical support office
Users who use the products of Wuhan Maiwe Communication Co., Ltd. can call the technical support office of Wuhan Maiwe Communication Co., Ltd. Wuhan Maiwe Communication Co., Ltd. has professional technical engineers to answer your questions and help you in the first time Solve the product or usage problems you encountered.
4.3 Product repair or replacement
For product maintenance, replacement or return, in accordance with the processing procedures of Wuhan Maiwei Communication Co., Ltd., you should first contact Wuhan Maiwe Communication Co., Ltd.
The technical staff of the company will confirm, and then negotiate with the sales staff of Wuhan Maiwe Communication Co., Ltd. to complete the repair, replacement or return of the product.



References