Instruction Manual for BESTTEN models including: DD1-L Digital Lever with Keypad, DD1-L, Digital Lever with Keypad, Lever with Keypad, Keypad
Light Control – Page 2 – BESTTEN US
BESTTEN | High Quality and Reliable | Making Your Home Smart&Safe – BESTTEN US
File Info : application/pdf, 2 Pages, 5.69MB
DocumentDocumentRead this manual carefully before installing and operating! For any problems or issues, please contact support@ibestten.com or 1-800-358-6160. Our technical team will help you sort it out. BESTTEN R Hardware Digital Lever with Keypad Not Waterproof BESTTEN electronic door locks are not waterproof and should not be installed where they will be exposed to rain or other wet conditions. VIDEO Installation and Operation Guide Installation Overview B K GL M C A F J I E Package Includes: A Exterior Assembly -1 B Interior Assembly -1 C Mounting Plate -1 D AA Alkaline Batteries -4 E Keys -2 F Latch -1 G Strike Plate -1 H User Guide -1 I 1 1/8" Screw -1 J 1" Screw -2 K 5/16" Screw -2 L 3/4" Screw -4 M Optional Set Screw -1 Exterior Assembly Interior Assembly Mounting Plate AA Alkaline Batteries Keys Latch Strike Plate M Guide User Guide 1 1/8" Screw 1" Screw 5/16" Screw 3/4" Screw Optional Set Screw Please carefully check the above list to confirm all items have been received. If any items are missing, please contact BESTTEN Customer Care 1. Prepare Door Refer to Template for Door Prep Instructions Included in Packaging. NOTE: Skip this step if your door comes with pre-drilled holes. 3. Determine Door "Handing" and Install Lock Handle View from the front of the lock Right Handed Door Left Handed Door 4. Change Lever Handing (Optional) Reminder: Tail piece must be in the horizontal position only when removing or installing handles. 2. Install Latch and Strike Plate F 2-3/8" (60mm) PULL 2-3/4" (70mm) PUSH To convert between 2-3/8" (60mm) and 2-3/4" (70mm) backset 1. Pull or push the extension plate to the required size. F L G L Interchangeable Cylinder Horizontal Interchangeable Cylinder Pin Key Reminder: Tail piece must be in the horizontal position only when removing or installing handles. Interchangeable Cylinder The small hole must be facing down. Horizontal Interchangeable Cylinder Horizontal 5. Install Exterior Assembly 6. Install Wiring Connector Work with the Door Open 7. Install Interior Assembly NOTE: Make sure the tail piece and knob are both set in the VERTICAL position. Be careful not to pinch the control wire when assembling. K 8. Test the Lock Test the Lock 9. Test Operation Test that all buttons on the keypad are working. Test the Lock Button with Door Open Check that the rubber gasket is secured on the exterior assembly. Place the exterior assembly onto the door with the tail piece going through the latch assembly. Route the control wire through the door over the latch assembly. M (optional) Tail Piece (Vertical) The Tail Piece that goes through the door and connects the lock (See Diagram) MUST be in the VERTICAL position (Up and Down) during installation. IF THE TAIL PIECE IS NOT IN THE VERTICAL POSITION DURING INSTALLATION, THE LOCK WILL NOT FUNCTION CORRECTLY. Control Wire Secure mounting plate to door and exterior assembly Do Not Over Tighten Control Wire Make sure that all the pins on the control wire connector are straight and that the connector is fully installed and firmly connected. I Vertical Check the Lock/Unlock function and that the Lever fully retracts the Latch. This electronic lock requires (4) High Quality AA alkaline batteries. When all 4 batteries are installed in the correct position, you should hear 2 beeps and the keypad will illuminate. NOTE: Do not touch the keypad until the light turns off. Do not use rechargeable batteries or non-alkaline batteries. Test Unlock Function Press 1-2-3-4-5-6- OR 1-2-3-4- Default Administrator Code:123456 Default User Code:1234 Both Administrator Code and User Code can open the door Before Opening Door, Let Motor Complete Cycle. BESTTEN R Hardware Programming Instructions Test the keypad to ensure all the buttons work. Please change the Administrator Code and User Code as soon as possible after installation to insure security. AC Administrator Code Default:123456 UC User Code (4-8 digits) Default:1234 ID User ID (01-50, 2 digits) Each User Code is linked to a User ID 1. Change Administrator Code Input Admin Code (default 123456) Press Long Beep Press Press Input New Admin Code (6 digits) Press Short Beep Green Light · Indicates Successful Programming Step · Indicates Unlocking is Successful Red light · Indicates Failed Programming Step · Indicates Locking is Successful 5 Seconds During programming, if there are no inputs for 5 seconds, the programming will exit and fail to complete. Lock Button Lock Used to lock door Unlock Button Unlock Used to unlock door Programming Used in programming steps Re-enter New Admin Code (6 digits) Press Long Beep Green light flashes confirming success 2. Add a User Code When a NEW User Code is set, the default User Code (1234) is deleted for safety. Input Admin Code Press Long Beep Press 3. Unlock Door with User Code Input User Code Press Long Beep Press Input User ID (2 digits) between 01-50 Press Long Beep Input New User Code (4-8 digits) Press Short Beep 4. Delete a User Code Input Admin Code Press Long Beep Press Press Input Existing User ID (2 digits) between 01-50 Press Short Beep Re-enter New User Code (4-8 digits) Press Long Beep Green light flashes confirming success Re-enter User ID (2 digits) between 01-50 Press Long Beep Green light flashes confirming success 5. Delete All User Codes Input Admin Code Press Long Beep Press Press Re-enter Admin Code Press Long Beep Green light flashes confirming success 6. Additional Programming Functions Programming Symbols Lock / Clear Unlock / Programming Administrator Code Automatic Lock Function SET OR CANCEL AUTO LOCK You can set the lock to automatically lock after each time the lock is unlocked. Time value range = 20 - 900 seconds, enter the following: Set Auto Lock: Time Value 1 beep and green light confirms successful programming. Cancel Time Value Auto Lock: 00 TEMPORARILY DISABLE: While in Auto-Lock mode, unlock door using , within 5 seconds you must turn the locking knob by hand to the locked position, and then turn the locking knob back to the unlock position. The Auto-Lock mode is now disabled. RESTORE: To restore the Auto-Lock function, turn the locking knob by hand to the locked position, wait more than 2 seconds or press the Lock button on the keypad. Vacation Mode With Vacation Mode enabled, the system enters into low-power consumption mode. During this mode, all buttons and functions will be disabled until they are re-enabled. ENABLE: 10 1 Once the door is locked then vacation mode will be engaged and all buttons and functions will be disabled DISABLE: To disable the Vacation Mode, you must press and hold for more than 3 seconds, then input followed by to unlock the door. Vacation Mode is now disabled. NOTE: If you only press the for more than 3 seconds but do not input the system will remain in Vacation Mode. Secure Lockout Period Warning sounds and LED flashes red after 4 incorrect code attempts: Keypad shuts down for 60 seconds. 7. Additional Programming Functions SOUND ON AND OFF You can "mute" or turn the "sound on" on your lock by entering the following. (Factory setting is sound on). 1= Sound Off 2= Sound On Sound Off (1) - Light Indicator illuminates green. Sound On (2) - Hear 1 beep and Light Indicator illuminates green. Restore Factory Settings To reset the lock to the original factory settings including the Admin Code and all User Codes follow these steps: 1. Remove one battery for 10 seconds. 2. Reinsert the battery and wait for a long and short beep. 3. Quickly Press 3 times within 3 seconds (before the blue light turns off). 4. The lock will beep and the light indicator will turn green. Low Battery Warning Beeps and LED flashes red 7 times. Replace with high quality alkaline batteries. Note: Removing batteries does not erase active Administrator or User Codes. Function Guide Unlock / Valid programming 1 long beep and LED illuminates green Lock: 2 short beeps and LED illuminates red Invalid programming: 2 short beeps and LED flashes red twice Low voltage: Short beeps and LED flashes red seven times Super low voltage 4 short beeps and LED flashes red four times 4 Incorrect code entry attempts: 2 short beeps and LED illuminates red each attempt Power on: 1 long beep and 1 short beep and LED illuminates green Lock error: 3 long beeps and LED flashes red three times Troubleshooting Issue Interior Knob will not turn Solution Knob or vertical tailpiece is installed in incorrect position. · Remove Interior Assembly and verify that the locking knob and tailpiece are vertical. Lock will not function electronically Keypad not working Keypad beeps and LED flashes · Check that all batteries are high quality Alkaline Batteries. · Check for proper polarity (+-)of all batteries. · Check that the Control Wire is attached to the Interior Assembly and not damaged. · Check each wire for loose or disconnected wires. · Disconnect the wiring harness and reconnect the wiring harness. · Restore to factory settings · Wait 60 seconds, keypad may be locked out due to incorrect code. · Replace with 4 high quality alkaline batteries. · Ensure Wiring connector is fully engaged and secure. · Replace with 4 high quality alkaline batteries. WARRANTY BESTTEN warrants to the original customer that this product is free of defects in materials and workmanship for 3 years from the purchase date. Within this period, simply contact BESTTEN CARE with proof of purchase and reason of claim. We will replace the product for free. Any product which is subject to misuse or accidental damage is excluded from this warranty. BESTTEN CARE support@ibestten.com 1-800-358-6160 (Mon-Fri 9AM-5PM PST) For more products from BESTTEN, please visit our website www.ibestten.com. Contact Us First! Do Not Return to Store VIDEO Installation and Operation Guide