Submittal
3.0 Ton Convertible Air Handler
A4AH4P37A1C30C
March 2022
Outline Drawing
The outline drawing illustrates the physical dimensions and installation clearances for the air handler. Key dimensions are labeled A through H. The unit is approved for installation with clearances to combustible material as stated on the unit rating nameplate.
Minimum Unit Clearance Table (Recommended)
CLEARANCE | SIDES | FRONT | BACK | INLET DUCT | OUTLET DUCT |
---|---|---|---|---|---|
SERVICE | 2" | 21" | 0" | N/A | 2.59" |
Product Dimensions
Air Handler Model | A | B | C | D | E | F | H | Flow Control | Gas Line Braze |
---|---|---|---|---|---|---|---|---|---|
A4AH4P37 | 51.27 | 23.50 | 21.50 | 21.75 | 7.01 | 9.66 | 24.59 | TXV | 7/8 |
All dimensions are in inches.
Product Specifications
Specification | Details |
---|---|
MODEL | A4AH4P37A1C30C |
RATED VOLTS/PH/HZ | 208-230/1/60 |
RATINGS(a) | See O.D. Specifications |
INDOOR COIL Type | Plate Fin |
Rows F.P.I. | 3-14 |
Face Area (sq. ft.) | 5.50 |
Tube Size (in.) | 3/8 |
Refrigerant Control | TXV |
Drain Conn. Size (in.)(b) | 3/4 NPT |
DUCT CONNECTIONS | See Outline Drawing |
INDOOR FAN Type | Centrifugal |
Diameter-Width (In.) | 11 X 8 |
No. Used | 1 |
Drive - No. Speeds | Direct - 3 |
CFM vs. in. w.g. | See Fan Performance Table |
No. Motors H.P. | 1-1/3 |
Motor Speed R.P.M. | 825 |
Volts/Ph/Hz | 208-230/1/60 |
F.L. Amps | 2.5 |
FILTER Furnished? (c) | No |
REFRIGERANT | R-410A |
Ref. Line Connections | Brazed |
Coupling or Conn. Size - in. Gas | 7/8 |
Coupling or Conn. Size - in. Liq. | 3/8 |
DIMENSIONS Crated (In.) HxWxD | 52-1/2 x 26 x 24 |
Uncrated | 51-3/8 x 23-1/2 x 21-1/8 |
WEIGHT Shipping (Lbs.) / Net (Lbs.) | 145/138 |
(a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
(b) 3/4" Male Plastic Pipe (Ref: ASTM 1785-76)
(c) Remote filter required.
Minimum Airflow CFM
Heater | Minimum Heat Speed Tap | ||
---|---|---|---|
With Heat Pump | Without Heat Pump | ||
BAYHTR1504BRK, BAYHTR1504LUG, BAYHTR1505BRK, BAYHTR1505LUG | Low | Low | |
BAYHTR1508BRK, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510LUG, BAYHTR3510LUG | Low | Low | |
BAYHTR1517BRK | Low | Low | |
BAYHTR1523BRK | High | High | |
BAYHTR3517LUG | Low | Low |
Performance Data
Fixed Orifice Superheat Charging Table
Use a digital psychrometer to measure return air wet-bulb temperature and outdoor dry-bulb temperature to locate the target superheat. Do not attempt to charge the system if conditions fall outside this table. Add refrigerant to decrease superheat; remove refrigerant to increase superheat. Allow 10-15 minutes after changes for stabilization.
Outdoor Dry Bulb Temperature (F) | Indoor Wet Bulb Temp (F) | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
50 | 51 | 52 | 53 | 54 | 55 | 56 | 57 | 58 | 59 | 60 | 61 | 62 | 63 | 64 | 65 | 66 | 67 | 68 | 69 | 70 | 71 | 72 | 73 | 74 | 75 | 76 | 77 | 78 | |
55 | 7 | 9 | 10 | 11 | 12 | 14 | 15 | 17 | 18 | 20 | 21 | 23 | 24 | 26 | 27 | 29 | 30 | ||||||||||||
60 | 5 | 7 | 8 | 9 | 10 | 12 | 13 | 15 | 16 | 18 | 19 | 21 | 22 | 24 | 25 | 27 | 28 | 30 | 31 | ||||||||||
65 | 4 | 6 | 8 | 10 | 11 | 13 | 14 | 16 | 17 | 18 | 19 | 21 | 22 | 24 | 25 | 27 | 28 | 27 | 31 | ||||||||||
70 | 5 | 7 | 8 | 10 | 11 | 13 | 14 | 16 | 17 | 18 | 19 | 21 | 22 | 24 | 25 | 27 | 28 | 30 | 31 | ||||||||||
75 | 5 | 6 | 7 | 9 | 10 | 12 | 14 | 16 | 18 | 19 | 21 | 22 | 24 | 26 | 28 | 29 | 31 | 32 | |||||||||||
80 | 4 | 6 | 7 | 9 | 10 | 11 | 12 | 14 | 16 | 18 | 19 | 21 | 23 | 25 | 26 | 28 | 29 | 31 | 33 | ||||||||||
85 | 4 | 6 | 7 | 9 | 10 | 13 | 14 | 16 | 18 | 20 | 21 | 23 | 24 | 26 | 28 | 29 | 30 | 31 | 32 | ||||||||||
90 | 4 | 6 | 8 | 10 | 11 | 13 | 14 | 16 | 18 | 20 | 22 | 24 | 25 | 27 | 28 | 30 | 31 | ||||||||||||
95 | 4 | 6 | 8 | 10 | 13 | 14 | 16 | 18 | 20 | 22 | 23 | 25 | 26 | 28 | 29 | ||||||||||||||
100 | 6 | 8 | 10 | 12 | 13 | 16 | 18 | 20 | 21 | 23 | 25 | 27 | 29 | ||||||||||||||||
105 | 6 | 7 | 9 | 11 | 13 | 15 | 18 | 20 | 22 | 24 | 26 | 28 | |||||||||||||||||
110 | 4 | 7 | 9 | 11 | 13 | 16 | 18 | 21 | 23 | 26 | 28 | ||||||||||||||||||
115 | 6 | 9 | 12 | 14 | 16 | 19 | 21 | 24 | 26 |
Heater Pressure Drop Table
This table shows the air pressure drop in inches W.G. for various airflow rates (CFM) across different numbers of heater racks.
Airflow CFM | Number of Racks | Heater Racks | Heater Model | No. of Racks | ||||
---|---|---|---|---|---|---|---|---|
1 | 2 | 3 | 4 | |||||
1800 | 0.02 | 0.04 | 0.06 | 0.14 | BAYHTR1504 | 1 | ||
1700 | 0.02 | 0.04 | 0.06 | 0.14 | BAYHTR1505 | 1 | ||
1600 | 0.02 | 0.04 | 0.06 | 0.13 | BAYHTR1508 | 2 | ||
1500 | 0.02 | 0.04 | 0.06 | 0.12 | BAYHTR1510 | 2 | ||
1400 | 0.02 | 0.04 | 0.06 | 0.12 | BAYHTR3510 | 3 | ||
1300 | 0.02 | 0.04 | 0.05 | 0.11 | BAYHTR1517 | 3 | ||
1200 | 0.01 | 0.04 | 0.05 | 0.10 | BAYHTR3517 | 3 | ||
1100 | 0.01 | 0.03 | 0.05 | 0.09 | BAYHTR1523 | 4 | ||
1000 | 0.01 | 0.03 | 0.04 | 0.09 | BAYHTR1525 | 4 | ||
900 | 0.01 | 0.03 | 0.04 | 0.08 | ||||
800 | 0.01 | 0.03 | ||||||
700 | 0.01 | 0.02 | ||||||
600 | 0.01 | 0.02 |
Table 1. Air Flow Performance
This table presents the airflow performance (CFM) for the A4AH4P37A1C30C unit at various external static pressures and speed taps for both 230 Volt and 208 Volt systems. Values are with wet coil, no filter, and no heaters. CFM correction for dry coil is +3%. '+' indicates factory setting.
EXTERNAL STATIC (in w.g) | AIRFLOW | |||||
---|---|---|---|---|---|---|
Speed Taps -- 230 VOLTS | Speed Taps -- 208 VOLTS | |||||
High | Med | Low + | High | Med | Low + | |
0.1 | 1723 | 1356 | 1254 | 1651 | 1211 | 1129 |
0.2 | 1682 | 1340 | 1259 | 1631 | 1216 | 1123 |
0.3 | 1605 | 1291 | 1228 | 1572 | 1188 | 1096 |
0.4 | 1492 | 1211 | 1162 | 1474 | 1127 | 1047 |
0.5 | 1343 | 1100 | 1059 | 1336 | 1032 | 977 |
0.6 | 1158 | 957 | 919 | 1159 | 905 | 886 |
0.7 | 998 | 782 | 942 | 744 |
(a) For the A4AH4P37A1C30C in downflow applications, airflow must not exceed 1600 cfm due to condensate blow off.
Table 2. Electrical Data
This table provides electrical specifications for various heater models when paired with the A4AH4P37A1C30C air handler, detailing capacity, voltage, amperage, and overload protection for both 240 Volt and 208 Volt systems.
Heater Model No. | No. of Circuits/ Phases | 240 Volt | 208 Volt | ||||||
---|---|---|---|---|---|---|---|---|---|
Capacity kW BTUH | Heater Amps per Circuit | Minimum Circuit Ampacity | Maximum Overload Protection | Capacity kW BTUH | Heater Amps per Circuit | Minimum Circuit Ampacity | Maximum Overload Protection | ||
No Heater | 2.5 * | 3 | 15 | 2.5 * | 3 | 15 | |||
BAYHTR1504BRK BAYHTR1504LUG |
1/1 | 3.84 13100 | 16.0 | 23 | 25 | 2.88 9800 | 13.8 | 20 | 20 |
BAYHTR1505BRK BAYHTR1505LUG |
1/1 | 4.8 16400 | 20.0 | 28 | 30 | 3.6 12300 | 17.3 | 25 | 25 |
BAYHTR1508BRK BAYHTR1508LUG |
1/1 | 7.68 26200 | 32.0 | 43 | 45 | 5.76 19700 | 27.7 | 38 | 40 |
BAYHTR1510BRK BAYHTR1510LUG |
1/1 | 9.6 32800 | 40.0 | 53 | 60 | 7.2 24600 | 34.6 | 46 | 50 |
BAYHTR1517BRK-Circuit 1 (a) | 2/1 | 9.6 32800 | 40.0 | 53 | 60 | 7.2 24600 | 34.6 | 46 | 50 |
BAYHTR1517BRK-Circuit 2 | 4.8 16400 | 20.0 | 25 | 25 | 3.6 12300 | 17.3 | 22 | 25 | |
BAYHTR1523BRK-Circuit 1 (a) | 2/1 | 9.6 32800 | 40.0 | 53 | 60 | 7.2 24600 | 34.6 | 46 | 50 |
BAYHTR1523BRK-Circuit 2 | 9.6 32800 | 40.0 | 50 | 50 | 7.2 24600 | 34.6 | 43 | 45 | |
BAYHTR3510LUG | 1/3 | 9.6 32800 | 23.1 | 32 | 35 | 7.2 24600 | 20.0 | 28 | 30 |
BAYHTR3517LUG | 1/3 | 14.4 49100 | 34.6 | 46 | 50 | 10.8 36900 | 30.0 | 40 | 40 |
BAYHTR1517BRK with single circuit power source kit BAYSPEKT201A | 1/1 | 14.4 49200 | 60.0 | 83 | 90 | 10.8 36900 | 51.9 | 73 | 80 |
BAYHTR1523BRK with single circuit power source kit BAYSPEKT201A | 1/1 | 19.2 65600 | 80.0 | 108 | 110 | 14.4 49200 | 69.2 | 94 | 100 |
* = Motor Amps
(a) MCA and MOP for circuit 1 contains the motor amps
Features and Benefits
- Galvanized metal cabinet with captured foil face insulation
- 2% or less air leakage
- R-4.2 Insulating Value
- Multi-Position UP/Down Flow, Horizontal Left/Right
- ALL Aluminum Coil
- Electric Heaters with polarized plug connections (sold as accessory)
- R-410A Thermal Expansion Valve
- ECM Motor (3.5 – 5 Ton Models)
- Low Voltage Pigtail Connections
- Draw Through Design
- Horizontal Drain pan
- Fused 24V Power
- 5 year warranty
- Optional extended warranty available
Important: Condensate management kit is required for all 5 ton air handler models installed in downflow applications.
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
Document Version: A4AH4P37A1C-SUB-1D-EN (09 Mar 2022)