Installation Guide for APG models including: MPI-E, MPI-E Chemical, MPI-R, MPI-E MPI Magnetostrictive Level Sensors, MPI-E, MPI Magnetostrictive Level Sensors, Level Sensors, Sensors

MPI-E/R/E Chem

Product Installation Guides | Resources | APG, Inc.

MPI Installation Guide

Intrinsically Safe, Chemically Resistant Magnetostrictive Float Level Transmitter | APG Sensors


File Info : application/pdf, 3 Pages, 811.92KB

PDF preview unavailable. Download the PDF instead.

MPI-ER-E-Chem-install-guide
Thank You
Thanks for purchasing an MPI series magnetostrictive level sensor from us! We appreciate your business and your trust. Please take a moment to familiarize yourself with the product and this manual before installation. If you have any questions, at any time, don't hesitate to call us at 888525-7300.
 NOTE: Scan the QR code to the right to see the full user manual on your tablet or smartphone. Or visit www.apgsensors.com/support to find it on our website.

MPI Magnetostrictive Level Sensors Installation Guide
For MPI-E, MPI-E Chemical, and MPI-R Intrinsically Safe

Table of Contents
1. Description 2. How To Read Your Label 3. Warranty 4. Dimensions

5. Installation Guidelines & Instructions
6. Sensor and System Wiring
7. General Care

8. Repair Information 9. Hazardous Location Wiring

APG
R
Automation Products Group, Inc. 1025 W 1700 N Logan, UT 84321 www.apgsensors.com | phone: 888-525-7300 | email: sales@apgsensors.com

Part # 200339 Doc #9005625 Rev D

1 Description
The MPI series magnetostrictive level sensor provides highly accurate and repeatable level readings in a wide variety of liquid level measurement applications. It is certified for installation in Class I, Division 1, and Class I, Zone 0 hazardous areas in the US and Canada by CSA, and ATEX and IECEX for Europe and the rest of the world.
2 How To Read Your Label
Each label comes with a full model number, a part number, and a serial number. The model number for the MPI will look something like this:
 SAMPLE: MPI-R5-ZY-P3SB-120-4D-N
The model number correlates with all the configurable options and tells you exactly what you have. Compare the model number to the options on the datasheet to identify your exact configuration. You can also call us with the model, part, or the serial number and we can help you.
You'll also find all hazardous certification information on the label.
3 Warranty
This product is covered by APG's warranty to be free from defects in material and workmanship under normal use and service of the product for 24 months. For a full explanation of our Warranty, please visit https://www.apgsensors.com/about-us/terms-conditions. Contact Technical Support to receive a Return Material Authorization before shipping your product back.
Scan the QR code below to read the full explanation of our Warranty on your tablet or smartphone.

5 Installation Guidelines & Instructions
The MPI should be installed in an area--indoors or outdoors--which meets the following conditions:
· Ambient temperature between -40°F and 185°F (-40°C to 85°C) · Relative humidity up to 100% · Altitude up to 2000 meters (6560 feet) · IEC-664-1 Conductive Pollution Degree 1 or 2 · IEC 61010-1 Measurement Category II · No chemical corrosive to stainless steel (such as NH3, SO2, Cl2, etc.) (Not applicable to plastic-
type stem options) · Ample space for maintenance and inspection

Additional care must be taken to ensure: · The probe is located away from strong magnetic fields, such as those produced by motors,
transformers, solenoid valves, etc. · The medium is free from metallic substances and other foreign matter. · The probe is not exposed to excessive vibration. · The float(s) fit through the mounting hole. If the float(s) does/do not fit, it/they must be
mounted on the stem from inside the vessel being monitored. · The float(s) is/are oriented properly on the stem (See Figure 5.1 below). MPI-E floats will be
installed by the factory. MPI-R floats are typically installed by customer.

Taper

 IMPORTANT: Floats must be oriented properly on the stem, or sensor readings will be inaccurate and unreliable. Untapered floats will have a sticker or etching indicating the top of the float. Remove sticker
UP prior to use.

4 Dimensions

4.29"

3/4" NPT

3.70"

1/2"NPT

MPI-E Chemical Housing Dimensions

4.29" 3.70"

5.71" 4.92"
5.00" 4.25"

3/4" NPT 1/2" NPT

9.30" 8.51"

2x .27"

ZERO REFERENCE d
Min. 12" Max. 153"

ZERO REFERENCE

Note: for dual dimensions, large housing dimensions are above small housing dimensions.
Float Options

H & K 2.00"

Float Ref.

3.50"
MPI-E Housing Dimensions

Figure 5.1
ATEX Stated Conditions of Use: · Under certain extreme circumstances, the non-metalic parts incorporated in the enclosure of this equipment may generate an ignition-capable level of electrostatic charge. Therefore the equipment shall not be installed in a location where the external conditions are conducive to the build-up of electrostatic charge on such surfaces. In addition, the equipment shall only be cleaned with a damp cloth. · The enclosure is manufactured from Aluminum. In rare cases, ignition sources due to impact and friction sparks could occur. This shall be considered during installation.
Installation Instructions: · If your sensor's stem and floats fit through the mounting hole, carefully lower the assembly into the vessel, then secure the sensor's mounting option to the vessel. · If the floats do not fit, mount them on the stem from inside the vessel being monitored. Then secure the sensor to the vessel. · For sensors with float stops, refer to the assembly drawing included with the sensor for float stop installation locations.
Warning! The Kynar stem is susceptible to thermal expansion when the process temperature exceeds 73°F / 23°C. This expansion can be calculated as follows: Expansion = (Max Process Temperature (°F) -73)*.000108 * Kynar Stem Length). This is the distance that must be left between the end of the Kynar stem and the tank bottom at the maximum process temperature.
Electrical Installation Instructions: · Remove the housing cover of your MPI. · Feed system wires into MPI through conduit openings. Fittings must be UL/CSA Listed for CSA installation and IP65 Rated or better. · Connect wires to MPI terminals. Use crimped ferrules on wires, if possible. · Replace housing cover.
See Sensor and System Wiring Diagrams (section 6) for Modbus wiring examples.
MPI-R Housing Dimensions

5.71"

d

3/4" NPT 1/2" NPT

4.21" 3.74"

4.92" 5.00" 4.25"

3/4" NPT

1/2" NPT

Housing

4.94" 4.15"

7.32-7.44" 6.53-6.65"

Connection Location
Ø 0.27"

2.38"
GND SCREW

ZERO REFERENCE
Note: For dual dimensions, large housing dimensions are above small housing dimensions.

3/4" NPT 1/2" NPT

4.21" 3.74"

4.94" 4.15"
1.90" GND SCREW

6.84" - 6.97" 6.05" - 6.18"
ZERO REFERENCE Note: For dual dimensions, large housing dimensions are above small housing dimensions.

5.71" 4.92" 5.00" 4.25"

3/4" NPT 1/2" NPT Housing Connection Location
Ø 0.27"

6 Sensor and System Wiring Diagrams MPI-E/R Intrinsically Safe Modbus System Wiring

Power Supply

+8-24 Vdc GND

Use Shielded Cable

Wiring T's must be located on controller/supply side of IS barriers.

Server Device

RS-485 A (TX+) RS-485 B (TX-)

120  terminating resistor may be necessary for long
cable runs.

Note: When connecting MPI sensors to your system, reversing A and B connections may be necessary if sensors do not communicate with Modbus Server device.

See Hazardous Installation Drawing for Intrinsically Safe installation requirements. Otherwise, wire directly.

See Hazardous Installation Drawing for Intrinsically Safe installation requirements. Otherwise, wire directly.

See Hazardous Installation Drawing for Intrinsically Safe installation requirements. Otherwise, wire directly.

MPI Sensor
Sensor 1
V+ B (TX-) A (TX+)
GND

MPI Sensor
Sensor 2
V+ B (TX-) A (TX+)
GND

MPI Sensor
Sensor 3
V+ B (TX-) A (TX+)
GND
120  terminating resistor across A & B terminals of last or only sensor, if necessary.
For installations without IS barriers only.

MPI-E/R Intrinsically Safe Modbus System Wiring with RST-6001

Power Supply

+8-24 Vdc GND

Use Shielded Cable

Wiring T's must be located on controller/supply side of IS barriers.

RST-6001 Modbus Controller
USB to computer with APG Modbus software

A B -5V +5V
Equivalent 120  terminating resistor internal to RST-6001

See Hazardous Installation Drawing for Intrinsically Safe installation requirements. Otherwise, wire directly.

See Hazardous Installation Drawing for Intrinsically Safe installation requirements. Otherwise, wire directly.

See Hazardous Installation Drawing for Intrinsically Safe installation requirements. Otherwise, wire directly.

Note: An independent +8-24 Vdc power supply is required when using an RST-6001 Modbus Controller. The RST-6001 can only supply ±5 Vdc, not the +8-24 Vdc required by the MPI.

MPI sensor
Sensor 1
V+ B A GND

MPI sensor
Sensor 2
V+ B A GND

MPI sensor
Sensor 3
V+ B A GND

120  terminating resistor across A & B terminals of last or only sensor, if necessary.
For installations without IS barriers only.

 IMPORTANT: Refer to section 9 for Hazardous Location Wiring.

 NOTE: For APG Modbus programming instructions, please see MPI user manual. APG Modbus software can be downloaded from www. apgsensors.com/support.

 IMPORTANT: MPI level sensor MUST be installed according to drawing 9005491 (Intrinsically Safe Installation Drawing for Hazardous Areas) in section 9 to meet listed approvals. Faulty installation will invalidate all safety approvals and ratings.

MPI - MDI Use Case Diagram

Hazardous Area
Zone 1
MDI Modbus Address: Server Controling: Sensor 1

Zone 0 or Zone 1
MPI Sensor Modbus Address: 1

MPI - MDI with Passive Controller Use Case Diagram

Non-hazardous Area

Hazardous Area
Zone 1
MDI Modbus Address: Server Controling: Sensor 1

Passive Control Equipment Modbus: Sniffer Sniffing: MDI

Approved IS Barrier

Zone 0 or Zone 1
MPI Sensor Modbus Address: 1

7 General Care

8 Repair Information

Your level sensor is very low maintenance and will need little care as long as it was installed correctly. However, in general, you should periodically inspect your MPI unit to ensure the stem is free of any heavy buildup that might impede the movement of the float(s). If sediment or other foreign matter becomes trapped between the stem and float(s), detection errors can occur.
If you need to remove the floats(s) from the stem of your MPI, be sure to note the orientation of the float(s) prior to removal. This will help ensure proper re-installation of the float(s).

If your MPI level sensor needs repair, contact us via email, phone, or online chat on our website. We will issue you a Return Material Authorization (RMA) number with instructions.
· Phone: 888-525-7300 · Email: sales@apgsensors.com · Online chat at www.apgsensors.com

Also, ensure that the housing cover is snuggly secured. If the cover becomes damaged or is misplaced, order a replacement immediately.

DANGER: WARNING -- POTENTIAL ELECTROSTATIC CHARGING HAZARD - CLEAN ONLY WITH A DAMP CLOTH; AVERTISSEMENT -- DANGER DE CHARGE ELECTROSTATIQUE POTENTIEL - NETTOYER SEULEMENT AVEC UN CHIFFON HUMIDE.

 IMPORTANT: All repairs and adjustments of the MPI level sensor must be made by the factory. Modifying, disassembling, or altering the MPI is strictly prohibited.

DANGER: OPEN CIRCUIT BEFORE REMOVING COVER or KEEP COVER TIGHT WHILE CIRCUITS ARE ALIVE; AVERTISSEMENT -- COUPER LE COURANTAVANT D'ENLEVER LE COUVERCLE, ou GARDER LE COUVERCLE FERME TANT QUE LES CIRCUITS SONT SOUS TENSION.
DANGER: WARNING -- EXPLOSION HAZARD -- SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY; AVERTISSEMENT -- RISQUE D'EXPLOSION -- LA SUBSTITION DE COMPOSANT PEUT AMELIORER LA SECURITE INTRINSIQUE.
DANGER: WARNING -- EXPLOSION HAZARD -- DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NONHAZARDOUS; AVERTISSEMENT -- RISQUE D'EXPLOSION -- AVANT DE DECONNECTER L'EQUIPEMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON DANGEREUX.
 IMPORTANT: Only the combustion gas detection performance of the instrument has been tested.

9 Hazardous Location Wiring

ZONE REV

--

B

DESCRIPTION See Change Order

REVISIONS CHANGE ORDER CO-3982

DATE 06/01/2020

APPROVED A. Fullmer

RS485+ RS485V+ V-

Unclassified Location

Associated Apparatus with Entity Parameters

Voc (or Uo)  Vmax (or Ui)

Isc (or Io)  Imax (or Ii)

Po

 Pi

Ca (or Co)  Ci + Ccable

La (or Lo)  Li + Lcable

Hazardous Location
Class I, Division 1, Groups C,D T4 Class I, Zone 0, AEx ia IIB T4 Ga Ex ia IIB T4 Ga, Ta -40°C to 85°C

A B VIN GND

MPI - RS485 RTU

Vmax (or Ui) = 28V

Imax (or Ii) = 280mA

Pi

= 850mW

Ci

= 0.374uF

Li

= 3.50uH

- Installation must be in accordance with NEC Articles 504 and 505.

PROPRIETARY AND CONFIDENTIAL
THIS DRAWING IS THE PROPERTY OF AUTOMATION PRODUCTS GROUP, INC.
LOGAN, UTAH AND MAY NOT BE USED, REPRODUCED, PUBLISHED, OR
DISCLOSED TO OTHERS WITHOUT WRITTEN CONSENT OF THE COMPANY.

APPROVALS
DRWN
C. Chidester
CHKD
S. Hutchins
APVD
R. Barson

DATE 6/5/2018 8/29/2018 8/29/2018

IF LOANED, IT IS SUBJECT TO RETURN

CONTRACT

UPON DEMAND AND MAY NOT BE USED

SIZE

IN ANY WAY DIRECTLY OR INDIRECTLY

MATL

DETRIMENTAL TO THE COMPANY.

A

FINISH

1025 West 1700 North Logan, Utah USA 888.525.7300

MPI Series Intrinsically Safe Installation Drawing
for Hazardous Locations

CAGE CODE

PART NO

DOCUMENT NO

REV

52797

VARIOUS

9005491

B

SHEET 1 OF 2

o 9000063 ev C



References

Adobe PDF Library 17.0 Adobe InDesign 18.2 (Macintosh)