Installation Guide for ASPEN models including: NTS03, NTS05, NTS08, NTS10, NTM03, NTM05, NTM08, NTM10, NTM15, NTL03, NTL05, NTL08, NTL10, NTL15, NTX03, NTX05, NTX08, NTX10, NTX15, NTX20, NCS03, NCS05, NCS08, NCS10, NCM03, NCM05, NCM08, NCM10, NCM15, NCL03, NCL05, NCL08, NCL10, NCL15, NCX03, NCX05, NCX08, NCX10, NCX15, N Series Electric Heat Kits, N Series, Electric Heat Kits, Heat Kits, Kits
1 II-002 | REV3 caused due to modification of the unit to operate with alternative power sources. NTS08 NTX03 NTX20 WARNING INSTALLATION INSTRUCTIONS
File Info : application/pdf, 4 Pages, 4.77MB
DocumentDocumentINSTALLATION INSTRUCTIONS "N" Series Electric Heat Kits for Aspen Multi-Position Air Handlers WARNING Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. The unit is designed for operation with 208/240 V, single phase, 60 Hz power supply. Aspen will not be responsible for damages caused due to modification of the unit to operate with alternative power sources. This product designed and manufactured to permit installation in accordance with local and national building codes. It is the installer's responsibility to ensure that product is installed in strict compliance with national and local codes. Manufacturer takes no responsibility for damage (personal, product or property) caused due to installations violating regulations. Installation of this unit shall be made in accordance with the National Electric Code, NFPA No. 90A and 90B, and any other local codes or utilities requirements. Do not bypass safety devices. Kit # Description NTS03 3KW Heat Strip w/ Terminal Block NTS05 5KW Heat Strip w/ Terminal Block NTS08 8KW Heat Strip w/ Terminal Block NTS10 10KW Heat Strip w/ Terminal Block NTM03 3KW Heat Strip w/ Terminal Block NTM05 5KW Heat Strip w/ Terminal Block NTM08 8KW Heat Strip w/ Terminal Block NTM10 10KW Heat Strip w/ Terminal Block NTM15 5KW Heat Strip w/ Terminal Block NTL03 3KW Heat Strip w/ Terminal Block NTL05 5KW Heat Strip w/ Terminal Block NTL08 8KW Heat Strip w/ Terminal Block NTL10 10KW Heat Strip w/ Terminal Block NTL15 15KW Heat Strip w/ Terminal Block NTX03 3KW Heat Strip w/ Terminal Block NTX05 5KW Heat Strip w/ Terminal Block NTX08 8KW Heat Strip w/ Terminal Block NTX10 10KW Heat Strip w/ Terminal Block NTX15 15KW Heat Strip w/ Terminal Block NTX20 20KW Heat Strip w/ Terminal Block Electric Heat Kits Kit # Description NCS03 3KW Heat Strip w/ Circuit Breaker NCS05 5KW Heat Strip w/ Circuit Breaker NCS08 8KW Heat Strip w/ Circuit Breaker NCS10 10KW Heat Strip w/ Circuit Breaker NCM03 3KW Heat Strip w/ Circuit Breaker NCM05 5KW Heat Strip w/ Circuit Breaker NCM08 8KW Heat Strip w/ Circuit Breaker NCM10 10KW Heat Strip w/ Circuit Breaker NCM15 15KW Heat Strip w/ Circuit Breaker NCL03 3KW Heat Strip w/ Circuit Breaker NCL05 5KW Heat Strip w/ Circuit Breaker NCL08 8KW Heat Strip w/ Circuit Breaker NCL10 10KW Heat Strip w/ Circuit Breaker NCL15 15KW Heat Strip w/ Circuit Breaker NCX03 3KW Heat Strip w/ Circuit Breaker NCX05 5KW Heat Strip w/ Circuit Breaker NCX08 8KW Heat Strip w/ Circuit Breaker NCX10 10KW Heat Strip w/ Circuit Breaker NCX15 15KW Heat Strip w/ Circuit Breaker INSTRUCTIONS: NCX20 20KW Heat Strip w/ Circuit Breaker Model used LEM24A-E LEM24F-J LEM36A-E LEM36F-J LEM48A-E LEM60A-E LEM48F-J LEM60F-J W/ Terminal Block W/ Circuit Breaker 1 II-002 | REV3 1) Refer to Table 1 for appropriate kit 2) Check kit for physical damage, do not installed damaged kit 3) Remove the upper access panel from air handler 4) Unplug the Mate-n-Lock connector (FIG. 3) and Remove block-off plate or existing heater kit from air handler by removing 6 screws (See FIG. 2) 5) Slide the heater kit into the slot and secure element plate and to divider deck with the six previously removed screws 6) Insert power leads into the circuit breaker lugs or terminal block and tighten (FIG. 3) 7) Connect ground wire to ground lug (FIG. 3) 8) Plug in the Mate-N-Lock connector 9) Break out appropriate number of circuit breaker openings (if applicable) on the access panel of the air handler FIG. 1 FIG. 2 (a) FIG. 3 (a) (b) 2 II-002 | REV3 10) Find the nameplate of the air handler unit and cross out the existing configuration and check the new heat kit model configuration that was installed. Nameplate shown below is a sample only. 11) Find the wiring diagram label that is included in the heat kit and stick it near the nameplate. Wiring Diagram shown below is a sample only. 3 II-002 | REV3 HOW TO REPLACE A DEFECTIVE THERMAL CUT OFF (TCO) OF A HEATER KIT: Fig. 1 TCO Image Screw TCO TCO Heater Kit Black Wire Fig. 2 Heater Kit w/ TCO 1. Disconnect power, unscrew and open upper access panels to access the heater kit from the unit. 2. Locate the TCO(s) and disconnect the 2 black wires per TCO. Using a multimeter, measure continuity/ resistance of the fuse element by placing the test probes across the two terminals to verify if the fuse has failed. The quantity of TCO's depends on the heater kit model. The heater kit model shown in Figure 2 has two TCOs. 3. Unscrew the defective TCO from the base plate and using the same screw(s) mount the new one back in the same spot. 4. Re-connect all the wirings in the same terminals that you disconnect it from. 5. Mount the access panel back in the unit. 373 Atascocita Rd., Humble, TX 77396 · Phone: 281.441.6500 · Toll Free: 800.423.9007 ·Fax: 282.441.6510 www.aspenmfg.com Subject to change without notice and without incurring obligation. © Copyright 2024 Aspen Manufacturing. All Rights Reserved 4 II-002 | REV3