User Guide for Hunter models including: WHCFLOW, Wireless HC Flow System

Wireless HC Flow System

Wireless HC Flow System - Hunter Industries

2 Introduction Never tunnel under or cut through a sidewalk again! Add wireless flow monitoring capabilities to your Hydrawise control system with this simple wireless communication kit.

2021-05-17 — The Wireless HC Flow communication kit helps save time, materials, and labor for any new installation or retrofit project. When asphalt, concrete, and other ...

PDF preview unavailable. Download the PDF instead.

rc-167-qsg-whcflow-us
Wireless HC Flow System
QUICK START GUIDE
WHCFLOW Wireless HC Flow System Wireless Communication System for use with HC Flow Meters

Introduction

Never tunnel under or cut through a sidewalk again! Add wireless flow monitoring capabilities to your Hydrawise® control system with this simple wireless communication kit.
The Wireless HC Flow communication kit helps save time, materials, and labor for any new installation or retrofit project. When asphalt, concrete, and other hardscape get in the way, easily pair the wireless transmitter and receiver with any HC Flow Meter* to monitor system hydraulics.
Send station-level flow rates and totals wirelessly from the sensor to the controller, without the need to run wire or dig trenches.
· Provides 500' (152 m) line-of-sight communication from transmitter to receiver
· Compatible with HC, HPC, Pro-HC, and HCC controllers

The Wireless HC Flow Meter is compatible with the Hydrawise web-based irrigation management platform. For setup instructions, visit https://support.hydrawise.com.
SCAN
for help
https://hunter.help/whcflow

* Flow meter sold separately.
2

1. Receiver

2. Receiver retaining nut



3. Wiring harness: white and blue wires to sensor terminals; yellow wires to 24 VAC terminals 







WHCFLOW Components

 







1. Transmitter

2. Transmitter retainer nut

3. White and blue wires (to sensor)

4. Battery pack (3 AA)

5. O-rings

6. Battery compartment cover

7. Battery compartment cap

3

System Overview and Operations

The Wireless HC Flow communication kit pairs with any HC Flow Meter* to provide wireless flow monitoring capabilities with Hydrawise enabled controllers. Compatible flow meters and controllers include:
· HC-075-FLOW (-B), HC-100-FLOW (-B), HC-150-FLOW (-B), HC-200-FLOW (-B)
· HC, HPC, Pro-HC, and HCC controllers
The Wireless HC Flow kit provides 500' (152 m) line-ofsight communication from transmitter to receiver.
Flow data is transmitted wirelessly every 5 seconds, indicated by a blinking green LED on both the transmitter and receiver.

The Wireless HC Flow receiver is powered by the 24 VAC terminals within the controller.
The Wireless HC Flow transmitter is battery powered (3 AA) and has two wires coming from it for connection to the HC Flow Meter.
Transmitter and HC Flow Meter Installation Details

* Flow meter sold separately.
4

Transmitter Installation
1. Using a hole saw, cut a 3¼" (8.25 cm) diameter hole in the valve box lid.
2. Unthread the transmitter retainer nut and feed the transmitter through the hole in the valve box lid so the mushroom cap is exposed.
3. Secure the transmitter in place by threading the transmitter retainer nut clockwise until snug against the valve box lid ribs.
4. Using the included waterproof connectors, splice the white wire from the transmitter to the white wire from the HC Flow Meter. Then splice the transmitter blue wire to the HC Flow Meter blue wire.

Installation


 

3¼" (8.25 cm)


Note: Cap the red wire from the flow meter with a waterproof splice. This wire is not used.
5

Installation
Receiver Installation · The Wireless HC Flow Receiver mounts to and is
powered by its host controller. · For best results, mount the receiver through one
of the side knockouts on the controller. Use a 7/8" (22 mm) hole saw to remove the knockout. Feed the wires and threaded nipple through the knockout into the controller, and secure in place with the receiver retaining nut.
7/8" (22 mm)
6

· Connect the two yellow wires to either 24 VAC terminals.
· Connect the white and blue wires to the sensor terminals.

HC

HPC

24V 24V SENSOR 1 SENSOR 2 COMMON

AC2 AC1 GND
SEN SEN

Pro-HC

24 VAC 24 VAC GND SEN-1 SEN COM SEN-2

HCC
SEN 1 SEN 2 SEN C REM 24VAC 24VAC
GND

Installation

Pairing the Transmitter and Receiver
The transmitter and receiver are preconfigured for wireless communication right out of the box. After applying power to either the transmitter or receiver, wait a minimum of 10 seconds for the power up sequence to complete. During this time, there will be one or more green LED blinks before the unit is ready for operation.
When flow is occurring, the transmitter will transmit flow sensor data at a maximum rate (depending on flow) of once every 5 seconds. The receiver LED will flash green at the same rate to indicate that flow is occurring.

Low-Battery Indication (Transmitter)
The receiver LED will flash red twice every 3 seconds to indicate a low or discharged battery. This battery status update will occur only during flow conditions.

7

System Considerations
When multiple controllers and sensors are within close proximity of one another, users should change the radio channels to prevent cross-talk between the transmitters and receivers. There are eight dip switch positions within both the transmitter and receiver, labeled as 1­8. The factory default setting for both the transmitter and receiver has dip switch position 1 set to ON, and all other dip switches set to OFF. To change the channel, simply change the dip switch positions. Example: Using a flathead screwdriver, flip dip switch position 1 to OFF, and flip switch position 2 to ON (do this for both the transmitter and receiver).
Receiver Dip Switches
Transmitter Dip Switches
8

Notices

FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment

does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, you are encouraged to try to correct the interference by taking one or more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit different from that of which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by Hunter Industries could void the user's authority to operate this device. If necessary, consult a representative of Hunter Industries Inc. or an experienced radio/ television technician for additional suggestions.

9

Notices

ISED
This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
1. L'appareil ne doit pas produire de brouillage, et
2. L'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.

CE Hereby, Hunter Industries declares that the radio equipment type models W-HC-FLOW-TR-INT and W-HC-FLOW-R-INT are in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://subsite.hunterindustries.com/compliance.
https://hunter.info/compliance

10

Notes
11

Helping our customers succeed is what drives us. While our passion for innovation and engineering is built into everything we do, it is our commitment to exceptional support that we hope will keep you in the Hunter family of customers for years to come.
Gregory R. Hunter, CEO of Hunter Industries
Gene Smith, President, Landscape Irrigation and Outdoor Lighting

HUNTER INDUSTRIES | Built on Innovation® 1940 Diamond Street, San Marcos, CA 92078 USA hunterindustries.com

© 2021 Hunter IndustriesTM. Hunter, all related logos, and all other trademarks are property of Hunter Industries, registered in the U.S. and other countries. Please recycle.

RC-167QSGEN2/21


Adobe PDF Library 15.0 Adobe InDesign 16.1 (Macintosh)