Owner's Manual for Sensor models including: ER-A Indoor Recessed PIR Infrared Motion Sensor Head, ER-A, Indoor Recessed PIR Infrared Motion Sensor Head, Recessed PIR Infrared Motion Sensor Head, PIR Infrared Motion Sensor Head, Motion Sensor Head, Sensor Head

ER-A-5VDC-Indoor-Recessed-PIR-Infrared-Motion-Sensor-Head

Concealed, PIR Infrared Motion Sensor Head

Concealed, PIR, Infrared, Motion, Sensor, Head

superlightingled

ER-A 5VDC Indoor Recessed PIR Infrared Motion Sensor Head

Sensor

ER-A 5VDC vnitřní zapuštěná hlava infračerveného snímače pohybu PIR

PDF preview unavailable. Download the PDF instead.

ER-A-5VDC-Indoor-Recessed-PIR-Infrared-Motion-Sensor-Head
ER-A
PIR Motion Sensing Head
 Concealed PIR motion sensing head.  Sensor head detection distance: 3-4 meters, detection angle: 120°.  Powered by low voltage 5VDC, output 5V level signal.  Bilateral snap design for easy installation.  Used for lighting stairs, garages, cabinets, closets, wine cabinets and more.

Sensor

Wiring Diagram
 Power supply using constant voltage power supply + junction box
2P distance: 3.81mm Output Current: 8A

LVD

Wire length: 1 meter +
S

Power input +
5V level signal, high is ON, low is OFF Power input -

+-
12-24VDC INPUT +
OUT OUT OUT OUT OUT OUT +- +- +- +- +- +-

Y

Y

Y

361

361

AC100-240V

Power Supply 12-24VDC Constant Voltage

MATCH

S SENSOR IN (5V)

CV 0

 Power supply using cabinet constant voltage power supply + junction box

Y

Y

Y

Y

Y

361

361

361

361

361

Single color LED strip

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

361

361

361

361

361

AC100-240V
L N

PBL-60-12/PBL-60-24

Vo Vo +

MATCH

S SENSOR IN (5V)

CV 0

Sensing head installation

Wall mounting:

Diameter: 1.2~1.5m

Ceilling mounting:

3-4m 120°
Height: 1~1.5m

120° 3-4m

Diameter: 1.2~1.5m

User Manual Ver 1.0.0 2024.02

+-
12-24VDC INPUT +
OUT OUT OUT OUT OUT OUT +- +- +- +- +- +-

20mm

Y

Y

Y

Y

Y

Y

361

361

361

361

361

361

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

361

361

361

361

361

361

Single color LED strip

20mm

20mm

Hole diameter 17mm

24.5mm
Drilling depth 18.5mm

Page1

Sensing head application
120° 3-4m

Not in sensing range

Entering the sensing range

Out of the sensing range

When people enter the sensing range, the light turn on; when people exit the sensing range, the light turn off after 30 seconds.

Installation precaution
1. Recommended for wall mounting. 2. If the sensing head is exposed to direct sunlight, interference signal will be introduced. 3. The sensing head should be installed in a dry environment and keep away from windows, air conditioner and fans. 4. Make sure that the sensing head stays away from heat source, such as countertops, kitchen appliances which generate hot steam,
walls and windows in direct sunlight, air conditioner, heating, refrigerators, stoves and so on. 5. We recommended the wall-mounted installation height is1-1.5 meters and the ceilling mounting height is no more than 3 meters. 6. There should not be shelter(screen, furniture, large bonsai) within the range of detection.

User Manual Ver 1.0.0 2024.02