Instruction Manual for Honeywell Home models including: H8908AB Humidistat H8908CD Dehumidistat, H8908AB, Humidistat, H8908CD, Dehumidistat
H8908ASPST/U | Plumbing and Heating Wholesale, Inc
File Info : application/pdf, 12 Pages, 2.09MB
DocumentDocumentH8908A/B Humidistat; H8908C/D Dehumidistat APPLICATION The H8908 family of low-voltage humidistats/ dehumidistats provide accurate control of whole house humidifiers, dehumidifiers, and ventilators. They have a snap-acting, dust-proof SPST switch and can be mounted to a duct or wall. Before Installing this Product... 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. CAUTION Personal Injury Hazard. Power supply can cause electrical shock. Disconnect power supply before beginning installation. NOTE: The H8908 electrical connections are not shared with the thermostat. INSTALLATION INSTRUCTIONS Fig. 1. H8908A,D control. Humidity Control Régulateur d'humidité OUTDOOR TEMPERATURE -20 F -10 F -30 C -25 C 0 F +10 F +20 F Over 20 F -20 C -10 C -5 C Over 0 C HUMIDITY SETTING 15% 20% 25% 30% 35% 40% M24726 HOLE FOR WIRING THE DUCT MOUNTING INSTALLATIONS CASE REMOVAL SLOT M13371 Fig. 2. H8908B,C control. 69-1341EF-09 H8908A/B HUMIDISTAT; H8908C/D DEHUMIDISTAT DUCT INSTALLATION 1. Choose a location on the duct. RETURN AIR ALTERNATE LOCATION RETURN AIR RETURN SUPPLY 6 in. (152 mm) MINIMUM BEST LOCATION 15 in. (381 mm) MINIMUM RETURN AIR DUCT M13369 Fig. 3. Duct installation locations. 2. Apply sticker template to duct and drill holes for mounting screws. Cut along the dotted line of the template with metal shears or tin snips. TWO-FAN 18-22 GAUGE WIRE M24720 Fig. 5. Run wire to the mounting location. REMOTE MOUNT INSTALLATION 1. Choose a location in the living area. NOTE: Select a location clear of drafts or excessive humidity. Avoid mounting near doors or windows, or in bathrooms or kitchens. See Fig. 6. M24800 Fig. 4. Drill and cut holes in duct. 3. Run two-fan, low-voltage wire to the mounting location on the duct. See Fig. 5. IMPORTANT Use rated 18-22 gauge wire. Leave approximately 6 in. of wire to properly connect the humidistat. M24718 Fig. 6. Choose a location in the living area. 2. Cut 1 in. diameter wire hole in wall. 3. Run two-fan, low-voltage wire to the mounting location in the living area. IMPORTANT Use rated 18-22 gauge wire. Leave approximately 6 in. of wire to properly connect the humidistat. 69-1341EF--09 2 H8908A/B HUMIDISTAT; H8908C/D DEHUMIDISTAT M24721 Fig. 7. Run wire to the mounting location. 4. Remove the base bracket from the humidistat. For duct mount, slide the black gasket onto the base bracket. See Fig. 8. NOTE: Use gasket only when mounting the control to ductwork. Leave off when mounting to a wall. M24733 Fig. 8. Seal base bracket. 5. Secure the base bracket to the duct or remote location. Secure to the duct with four 1-in. (25 mm) screws (provided) or to the wall with two 1in. (25 mm) screws (provided). M24722 Fig. 9. Mount base bracket to duct or remote location. 3 69-1341EF--09 H8908A/B HUMIDISTAT; H8908C/D DEHUMIDISTAT WIRING CAUTION Personal Injury Hazard. Can cause electrical shock and injury. Disconnect power before installation or servicing. All wiring must comply with applicable local codes, ordinances and regulations. Make wiring connections according to humidifier (or dehumidifier/ventilator) instructions, if available; otherwise, see typical wiring diagrams in Fig. 1218. IMPORTANT Select models of fan centers include humidifier taps so the current sensing relay, sail switch or air pressure switch is not needed. If not using a current sensing relay, sail switch, or air pressure switch, the humidifier must be energized during blower motor cycles for proper operation. On multispeed blower applications, do not wire the high voltage side of the transformer to the same power source that services the furnace blower. Premature transformer burnout can occur. On HE365 fan powered humidifier models, only the two yellow wires are connected to the control. The remaining two red wires are only used with electronic humidity controls. 6. Using wire nuts, connect the low-voltage wire to the leads on the H8908 humidistat. See Fig. 6 18 for different wiring configurations. the humidistat in to engage the base hinge. You will hear a "click" when the humidistat is secured. M24801 Fig. 11. Attach the humidistat to the base. H8908 L1 (HOT) L2 1 POWER SUPPLY FAN CONTROL FURNACE FAN MOTOR 30 20 40 50 10 60 OFF ON 2 TRANSFORMER 1 PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 24 VAC WIRING. HUMIDIFIER M24727 Fig. 12. Wiring H8908 with fan interlock. H8908 L1 (HOT) L2 POWER SUPPLY 1 FAN CONTROL 30 20 40 50 10 60 OFF ON 2 DPST SWITCHING RELAY TRANSFORMER M24734 Fig. 10. Wire the humidistat. 7. Mount the humidistat by hooking the two hinges at the top of the back cover to the raised edge at the top of the base bracket. Press the bottom of HL C 2-SPEED FAN MOTOR HUMIDIFIER 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 24 VAC WIRING. M24728 Fig. 13. Wiring H8908 with 2-speed fan motor. 69-1341EF--09 4 H8908 30 40 20 50 10 60 2 OFF ON WATER SOLENOID LEAD WIRE TRANSFORMER L2 L1 1 (HOT) CURRENT SENSING LO RELAY C HI HUMIDIFIER 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 24V WIRING. M24729 Fig. 14. Typical wiring diagram of current sensing relay with humidifier. AIR PRESSURE SWITCH/ SAIL SWITCH 2 H8908 30 20 10 OFF 40 50 60 ON TRANSFORMER 1 L2 L1 (HOT) HUMIDIFIER 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 24V WIRING. M24730B Fig. 15. Wiring H8908 in line with air pressure switch/sail switch and humidifier. H8908A/B HUMIDISTAT; H8908C/D DEHUMIDISTAT H8908 30 20 10 OFF 40 50 60 ON FAN WIRING TERMINALS 1 HUMIDISTAT TERMINALS 1 24V WIRING. HUMIDIFIER 1 TO SYSTEM FAN NOTE: FOLLOW THE INSTALLATION INSTRUCTIONS INCLUDED WITH THE STEAM HUMIDIFIER TO WIRE THE SYSTEM FAN. M24731 Fig. 16. Wiring H8908 with steam humidifiers. 1 G (THERMOSTAT) R G (FURNACE) H8908 30 20 10 OFF 40 50 60 ON AIR PROVING DEVICE 2 POWER IN HE150/HE250/HE300 Humidifier LEFT RIGHT 1 ONLY NEEDED IF SYSTEM'S THERMOSTAT DOES NOT ISOLATE Y FROM G. IF NEEDED, BREAK THE THERMOSTAT G TO SYSTEM G CONNECTION AND ROUTE THROUGH HUMIDIFIER AS SHOWN. 2 HE150/HE250 USES A 15 VA TRANSFORMER WIRED INTO 24V IN. HE100/HE200 USES A 10 VA TRANSFORMER WIRED INTO 24V IN. HE300 USES A LINE CORD PLUG. M35155A Fig. 17. Wiring to force fan on and prove airflow in the duct. H8908D 30 20 10 OFF 40 50 60 ON VENTILATOR/DEHUMIDIFIER TERMINALS Fresh Air Ventilation System Système de ventilation à air frais M24732 Fig. 18. Typical wiring diagram for HR150, HR200, ER150 and ER200 Ventilator or DH90 Dehumidifier applications. 5 69-1341EF--09 H8908A/B HUMIDISTAT; H8908C/D DEHUMIDISTAT CHECKOUT Turn the H8908 dial to "ON" to test proper installation. See Fig. 19. You will hear an audible click if installed correctly, and water will begin flowing to the humidifier. Humidity Control Régulateur d'humidité OUTDOOR TEMPERATURE -20 F -10 F -30 C -25 C 0 F +10 F +20 F Over 20 F -20 C -10 C -5 C Over 0 C HUMIDITY SETTING 15% 20% 25% 30% 35% 40% OPERATION Humidity Control Adjustment To maintain optimal humidity levels without causing condensation on cold surfaces such as windows, the homeowner must adjust the setpoint as the outdoor temperature changes. To reduce the relative humidity, lower the setpoint approximately three percent relative humidity every 24 hours. To increase the relative humidity, increase the setpoint approximately three percent relative humidity every 24 hours. Setpoint Adjustment Set the humidity setpoint according to the prevailing outdoor temperature. Recommended settings are available on the control and in the table below. Table 1. Recommended Humidity Controller Settings. Outdoor Temperature °F °C -20 -29 -10 -23 0 -18 +10 -12 +20 -7 >+20 >-7 Recommended H8908A,B Setpoints 15 20 25 30 35 40 M24723 Fig. 19. Turn humidistat on. Outdoor Temperature °F +70 +75 +80 +85 +90 >+100 °C +21 +24 +27 +29 +32 >+38 Recommended H8908C,D Setpoints 50 40 35 30 25 20 Resideo Inc., 1985 Douglas Drive North, Golden Valley, MN 55422 www.resideo.com 69-1341EF--09 M.S. Rev. 11-19 | Printed in United States This product is manufactured by Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502 ©2019 Resideo Technologies, Inc. The Honeywell Home trademark is used under license from Honeywell International Inc. All rights reserved. Humidistat H8908A/B Déshumidistat H8908C/D APPLICATION Les humidistats et les déshumidistats basse tension de la gamme H8908 assurent la régulation précise de l'humidification, la déshumidification et la ventilation dans toute la maison. Ils fonctionnent au moyen d'un interrupteur unipolaire unidirectionnel à rupture brusque, à l'épreuve de la poussière. Ils peuvent être installés sur une gaine ou sur un mur. AVANT D'INSTALLER CET APPAREIL... 1. Lire attentivement les présentes instructions. Le fait de ne pas les suivre risque d'endommager le produit ou de constituer un danger. 2. Vérifier les caractéristiques spécifiées dans les instructions et indiquées sur le produit, et s'assurer que celui-ci correspond à l'application prévue. 3. L'installateur doit être un technicien d'expérience ayant reçu une formation pertinente. CAUTION Risque de blessure. Peut donner un choc électrique. Couper l'alimentation avant de procéder à l'installation. REMARQUE : Les connexions du H8908 et du thermostat ne sont pas communes. NOTICE D'INSTALLATION Fig. 1. Régulateur H8908 A et D. M24726 Humidity Control Régulateur d'humidité OUTDOOR TEMPERATURE -20 F -10 F 0 F +10 F +20 F Over 20 F -30 C -25 C -20 C -10 C -5 C Over 0 C HUMIDITY SETTING 15% 20% 25% 30% 35% 40% ORIFICE POUR LE CÂBLAGE DANS LES INSTALLATIONS SUR GAINE FENTE DE DÉGAGEMENT DU BOÎTIER MF13371 Fig. 2. Régulateur H8908 B et C. 69-1341EF-09 HUMIDISTAT H8908A/B DÉSHUMIDISTAT H8908C/D INSTALLATION SUR UNE GAINE 1. Choisir l'emplacement sur la gaine. RETOUR D'AIR EMPLACEMENTS POSSIBLES RETOUR D'AIR MAXIMUM 152 mm (6 po) EMPLACEMENT PRÉFÉRABLE MINIMUM 381 mm (15 po) RETOUR ALIMENTATION D'AIR GAINE DE RETOUR D'AIR MF13369A Fig. 3. Emplacements possibles pour installation sur une gaine. 2. Coller le gabarit sur la gaine à l'emplacement choisi. Percer les trous pour les vis de montage. À l'aide de cisailles à métal, découper la tôle en suivant la ligne pointillée. FIL DOUBLE POUR VENTILATEUR DE CALIBRE 18 À 22 MF24720 Fig. 5. Amener le fil jusqu'à l'emplacement de montage. MONTAGE À DISTANCE DANS UNE PIÈCE 1. Choisir l'emplacement de montage dans la pièce. M24800 REMARQUE : Choisir un emplacement à l'abri des courants d'air et de l'humidité excessive. Ne pas installer l'appareil près des portes ou des fenêtres ni dans la salle de bain ou la cuisine. Voir la figure 6. Fig. 4. Percer les trous et découper la gaine. 3. Amener un fil double basse tension pour ventila- teur jusqu'à l'emplacement de montage sur la gaine. Voir la Fig. 5. IMPORTANT Utiliser du fil de calibre 18 à 22. Prévoir une quinzaine de centimètres (6 po) de fil pour effectuer le raccordement de l'humidistat. 69-1341EF--09 M24718 Fig. 6. Choisir l'emplacement dans la pièce. 2. Découper un trou de 2,5 cm (1 po) pour passer le fil dans le mur. 3. Amener un fil double basse tension pour ventila- teur jusqu'à l'emplacement de montage dans la pièce. Voir la Fig. 5. IMPORTANT Utiliser du fil de calibre 18 à 22. Prévoir une quinzaine de centimètres (6 po) de fil pour effectuer le raccordement de l'humidistat. 2 HUMIDISTAT H8908A/B DÉSHUMIDISTAT H8908C/D M24721 Fig. 7. Amener le fil jusqu'à l'emplacement de montage. 4. Retirer la plaque de montage de l'humidistat. Dans le cas d'une installation sur une gaine, insérer la garniture d'étanchéité sur la plaque de montage. Voir la Fig. 8. REMARQUE : Utiliser la garniture seulement pour une installation sur une gaine. Ne pas l'utiliser dans le cas d'une installation sur un mur. M24733 Fig. 8. Poser la garniture d'étanchéité. 5. Poser la plaque de montage sur la gaine ou à l'emplacement choisi dans la pièce. Fixer à la gaine avec les quatre vis de 25 mm (1 po) fournies. Fixer au mur avec les deux vis de 25 mm (1 po) fournies. M24722 Fig. 9. Poser la plaque de montage sur la gaine ou sur le mur. 3 69-1341EF--09 HUMIDISTAT H8908A/B DÉSHUMIDISTAT H8908C/D RACCORDEMENT CAUTION Risque de blessure Peut causer des chocs électriques et des blessures. Débrancher toute source d'alimentation avant d'installer ou de réparer. Appuyer sur le bas de l'humidistat pour enclencher la charnière du bas. Un clic se fait entendre lorsque l'humidistat est bien en place. Tout le câblage doit être conforme aux codes et aux règlements locaux. Effectuer les raccordements en suivant la notice technique de l'humidificateur, du déshumidificateur ou du ventilateur si elle existe. Sinon, consulter les schémas de raccordement aux figures Fig. 1218. IMPORTANT Pour certains modèles de commandes de ventilateur qui ont des connections pour un humidificateur, le relais ampéremétrique, interrupteur à ailette ou un pressostat d'air n'est pas nécessaire. Si vous n'utilisez pas de relais ampéremétrique, interrupteur à ailette ou pressostat d'air, l'humidificateur doit être mis sous tension en même temps que le ventilateur. Dans les applications avec ventilateur à plusieurs vitesses, ne pas raccorder le côté haute tension du transformateur à la même source d'alimentation que celle du ventilateur de l'appareil de chauffage. Il pourrait en résulter un grillage prématuré du transformateur. Avec les humidificateurs HE365 avec ventilateur, ne raccorder que les deux fils jaunes au régulateur. Les deux fils rouges ne servent que dans le cas de régulateurs d'humidité électroniques. 6. Utiliser des connecteurs de fils pour raccorder les fils basse tension aux connecteurs de l'humidistat H8908. Consulter les Fig. 618 pour connaître les configurations possibles. M24801 Fig. 11. Fixer l'humidistat sur la plaque de montage. H8908 COMMANDE DU VENTILATEUR L1 (SOUS TENSION) ALIMENTATION L2 1 MOTEUR DU VENTILATEUR DE L'APPAREIL DE CHAUFFAGE 30 20 40 50 10 60 OFF ON 2 TRANSFORMATEUR 1 FOURNIR, AU BESOIN, UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRELES SURCHARGES. 2 CÂBLAGE 24 V c.a. HUMIDIFICATEUR MF24727 Fig. 12. Raccordement du H8908 avec asservissement du ventilateur. H8908 L1 (SOUS TENSION) ALIMENTATION L2 1 COMMANDE DU VENTILATEUR FAN CONTROL 30 20 40 50 10 60 OFF ON 2 RELAIS COMMUTATION TRANSFORMATEUR BIPOL. UNIDIR. HL C MOTEUR VENTILATEUR 2 VITESSES M24734 Fig. 10. Raccorder l'humidistat. 7. Pour monter l'humidistat, accrocher les deux charnières au haut du couvercle arrière aux pattes au haut de la plaque de montage. HUMIDIFICATEUR 1 ALIMENTATION. FOURNIR, AU BESOIN, UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES. 2 CÂBLAGE 24 V c.a. MF24728 Fig. 13. Raccordement du H8908 avec un moteur de ventilateur à deux vitesses. 69-1341EF--09 4 H8908 30 40 20 50 10 60 2 OFF ON FILS DU SOLÉNOÏDE DE L'EAU HUMIDISTAT H8908A/B DÉSHUMIDISTAT H8908C/D 1 G (THERMOSTAT) G R (APPAREIL DE CHAUFFAGE) H8908 30 20 10 OFF 40 50 60 ON DISPOSITIF DE VÉRIFICATION DE PRÉSENCE D'AIR 2 ENTRÉE ÉLECTRIQUE TRANSFORMATEUR L2 1 L1 (SOUS TENSION) RELAIS À CAPTEUR DE COURANT LO C HI HUMIDIFICATEUR 1 ALIMENTATION. FOURNIR, AU BESOIN, UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES. 2 CÂBLAGE 24 V c.a. MF24729 Fig. 14. Schéma de raccordement typique d'un relais à capteur de courant avec un humidificateur. H8908 PRESSOSTAT D'AIR/ INTERRUPTEUR À AILETTE 2 30 20 10 OFF 40 50 60 ON TRANSFORMATEUR 1 L2 L1 (SOUS TENSION) HUMIDIFICATEUR 1 ALIMENTATION. FOURNIR, AU BESOIN, UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES. 2 CÂBLAGE 24 V c.a. MF24730B Fig. 15. Raccordement du H8908 en série avec pressostat d'air/interrupteur à ailette et humidificateur. H8908 HE150/HE250/HE300 HUMIDIFICATEUR GAUCHE DROIT 1 NÉCESSAIRE UNIQUEMENT SI LE THERMOSTAT DU SYSTÈME N'ISOLE PAS Y DE G. SI NÉCESSAIRE, COUPEZ LA CONNEXION DU G DU THERMOSTAT AU G DU SYSTÈME ET ACHEMINEZ PAR L'HUMIDIFICATEUR COMME ILLUSTRÉ. 2 LES MODÈLES HE150/HE250 UTILISENT UN TRANSFORMATEUR DE 15 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V. LES MODÈLES HE100/HE200 UTILISENT UN TRANSFORMATEUR DE 10 VA CÂBLÉ DANS UNE ENTRÉE DE 24 V. LE MODÈLE HE300 UTILISE UNE PRISE SUR CORDON DE SECTEUR. MF35155A Fig. 17. Câblage forçant l'activation du ventilateur pour assurer un débit d'air dans la gaine. H8908D 30 20 10 OFF 40 50 60 ON VENTILATEUR/DÉSHUMIDIFICATEUR BORNES Fresh Air Ventilation System Système de ventilation à air frais MF24732 Fig. 18. Schéma de raccordement typique dans des applications de ventilation avec un HR150, HR200, ER150 et ER200 ou de déshumidification avec un DH90. 30 20 40 50 BORNES DE RACCORDEMENT DU VENTILATEUR 10 60 OFF ON 1 1 BORNES DE L'HUMIDISTAT 1 CÂBLAGE 24 V c.a. HUMIDIFICATEUR VERS LE VENTILATEUR DU SYSTÈME REMARQUE : SUIVRE LES INSTRUCTIONS D'INSTALLATION DE L'HUMIDIFICATEUR À VAPEUR POUR RACCORDER LE VENTILATEUR DU SYSTÈME. MF24731 Fig. 16. Raccordement du H8908 avec un humidificateur à vapeur. 5 69-1341EF--09 HUMIDISTAT H8908A/B DÉSHUMIDISTAT H8908C/D VÉRIFICATION Tourner le cadran du H8908 jusqu'à la position « marche » pour vérifier le fonctionnement de l'installation. Voir la Fig. 19. Si l'installation est bien effectuée, un clic se fait entendre et l'eau commence à circuler dans l'humidificateur. Humidity Control Régulateur d'humidité OUTDOOR TEMPERATURE -20 F -10 F 0 F +10 F +20 F Over 20 F -30 C -25 C -20 C -10 C -5 C Over 0 C HUMIDITY SETTING 15% 20% 25% 30% 35% 40% FONCTIONNEMENT Réglage du régulateur d'humidité Pour obtenir un niveau d'humidité optimal sans condensation sur les surfaces froides comme les fenêtres, il faut régler le point de consigne de l'humidité en fonction de la température extérieure. Pour diminuer le taux d'humidité relative, abaisser le point de consigne d'environ trois pourcents d'humidité relative aux 24 heures. Pour augmenter le taux d'humidité relative, augmenter le point de consigne d'environ trois pourcents d'humidité relative aux 24 heures. Réglage du point de consigne Régler le point de consigne d'humidité relative en tenant compte de la température extérieure. Les réglages recommandés sont indiqués sur le régulateur et dans le tableau ci-dessous. Tableau 1. Réglages d'humidité recommandés. Température extérieure ° C ° F -29 -20 -23 -10 -18 0 -12 +10 -7 +20 >-7 >+20 Point de consigne recommandé H8908 A, B 15 20 25 30 35 40 M24723 Fig. 19. Tourner l'humidistat pour le mettre en marche. Température extérieure ° C +21 +24 +27 +29 +32 >+38 ° F +70 +75 +80 +85 +90 >+100 Point de consigne recommandé H8908 C, D 50 40 35 30 25 20 Resideo Inc., 1985 Douglas Drive North, Golden Valley, MN 55422 www.resideo.com 69-1341EF--09 M.S. Rev. 11-19 | Imprimé aux États-Unis Ce produit est fabriqué par Resideo Technologies, Inc., Golden Valley, MN, 1-800-468-1502 ©2019 Resideo Technologies, Inc. La marque de commerce Honeywell Home est utilisée sous licence avec l'autorisation d'Honeywell International Inc. Tous droits réservés.FrameMaker 2017.0.2 Acrobat Distiller 19.0 (Windows)