Instruction Manual for PPI models including: RTD Pt100 Self Tune PID Temperature Controller, RTD Pt100, Self Tune PID Temperature Controller, PID Temperature Controller, Temperature Controller, Controller
Self Tune PID Temperature Controller | PID Control with Self-Tuning
File Info : application/pdf, 2 Pages, 627.16KB
DocumentDocumentJan 2022 Composite `Temperature + Humidity' Controller Version : RTD Pt100, 3-wire for Temperature DC Linear (Voltage) for Humidity Operation Manual This brief manual is primarily meant for quick reference to wiring connections and parameter searching. For more details on operation and application; please log on to www.ppiindia.net 101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar - 401 210. Sales : 8208199048 / 8208141446 Support : 07498799226 / 08767395333 E: sales@ppiindia.net, support@ppiindia.net UTILITY PARAMETERS : PAGE-33 Parameters Settings (Default Value) Compressor Control Strategy Dry Bulb SP Dry Bulb PV (Default : Dry Bulb SP) Zero Offset for Temperature Value -25.0 to +25.0°C (Default : 0.0) Zero Offset for RH Value -25.0 to +25.0% (Default : 0.0) Range Low Range High -199.9 to 999.9 (Refer Table 1) (Default : 0.0) -199.9 to 999.9 (Refer Table 1) (Default : 151.5) TEMPERATURE PARAMETERS : PAGE-10 Parameters Settings (Default Value) Alarm-1 Band 0.3 to 25.0°C (Default : 0.5) Alarm-1 Hysteresis 0.2 to 10.0°C (Default : 0.2) Proportional Band 0.1 to 999.9°C (Default : 5.0) Integral Time 0 to 1000 Seconds (Default : 100) Derivative Time 0 to 250 Seconds (Default : 25) Cycle Time 0.5 to 25.0 Seconds (in steps of 0.5 secs.) (Default : 1.0) RELATIVE HUMIDITY (% RH) PARAMETERS : PAGE-11 Parameters Settings (Default Value) Alarm-2 Band 0.3 to 25.0% (Default : 2.0) Alarm-2 Hysteresis 0.2 to 10.0% (Default : 2.0) Parameters Proportional Band Integral Time Derivative Time Cycle Time Settings (Default Value) 0.1 to 999.9% (Default : 10.0) 0 to 1000 Seconds (Default : 100) 0 to 250 Seconds (Default : 25) 0.5 to 25.0 Seconds (in steps of 0.5 secs.) (Default : 1.0) OP3 FUNCTION PARAMETERS : PAGE-13 Parameters Settings (Default Value) Output-3 Function Selection Alarm Compressor (Default : Alarm) Compressor Setpoint 0.0 to 50.0°C or 0.0 to 25.0°C (Default : 45.0 or 0.2) Compressor Hysteresis 0.1 to 25.0°C (Default : 0.2) Compressor Time Delay 0.00 to 10.00 Min. Sec (in steps of 5 Seconds) (Default : 00.00) SUPERVISORY PARAMETERS : PAGE-12 Parameters Settings (Default Value) SP Adjustment on PAGE-0 Enable Disable (Default : Enable) Self-Tune Command No Yes (Default : No) Baud Rate (Default : 4800) Parameters ID for Temperature Loop ID for %RH Loop Settings (Default Value) 1 to 8 (Default : 1) 1 to 8 (Default : 2) COMPRESSOR OPERATION & POWER INDICATION : PAGE-1 Parameters Settings (Default Value) Compressor Operation Mode Automatic Off Output Power for Temperature Loop On (Default : Auto) 0 to 100.0% (View Only - Non editable) Output Power for %RH Loop 0 to 100.0% (View Only - Non editable) TABLE-1 RH INPUT CONFIGURATION The controller is calibrated for 0 to 5 VDC input for % RH. The transmitter output signal, however, may be any voltage between 0 to 5 VDC (For e.g. 0 to 1 VDC,1 to 3.6 VDC, 0 to 3.3 VDC etc.). The value for `Range Low' and `Range High' parameters must be corresponding to 0 and 5 VDC only. For this, use the following formulae for computing the `Range Low' and `Range High' values. 100 Range Low = Span X (0 - Signal Low) 100.0 Range High = Span X (5 - Signal Low) (where; Span = Signal High - Signal Low) Example 1 Signal Low = 0 VDC, signal High = 1.0 Vdc Range Low = 100.0 1.0 X (0 - 0) = 0.0 Range High = 100.0 X (5 - 0) = 500.0 1.0 Example 2 Signal Low = 0 VDC, signal High = 3.3 VDC Here, Span = 3.3 -0 = 3.3 VDC Example 3 Signal Low = 1.0 VDC, signal High = 3.6 VDC Here, Span = 3.6 - 1.0 = 2.6 VDC Range Low = 100.0 2.6 X (0 - 1.0) = -38.5 Range High = 100.0 2.6 X (5 - 1.0) = 153.8 Range Low = 100.0 3.3 X (0 - 0) = 0.0 Range High = 100.0 3.3 X (5 - 0) = 151.5 FRONT PANEL LAYOUT Front Panel PPI HumiTherm-c °C Upper Readout Lower Readout Tune Indicator Alarm -1 Indicator PAGE Key %RH 1 2 AL1 TUN AL2 Output-1 Indicator Output-2 Indicator Alarm-2 Indicator ENTER Key DOWN Key UP Key Symbol Key PAGE Keys Operation Function Press to enter or exit set-up mode. DOWN UP ENTER Press to decrease the parameter value. Pressing once decreases the value by one count; keeping pressed speeds up the change. Press to increase the parameter value. Pressing once increases the value by one count; keeping pressed speeds up the change. Press to store the set parameter value and to scroll to the next parameter on the PAGE. PV Error Indications For Dry Bulb Temperature (Upper Readout) Message PV Error Type Over-range (Dry-Bulb Temp. above Max. Range) Under-range (Dry-Bulb Temp. below Min. Range) Open (Sensor open / broken) PV Error Indications For Relative Humidity (RH) (Lower Readout) Message PV Error Type Over-range (Wet-Bulb Temp. above Max. Range) Under-range (Wet-Bulb Temp. below Min. Range) Open (Sensor open / broken) Either Dry Bulb Temp. is below 20.0°C or above 162.0°C. The error may also occur if Wet Bulb depression is more then 60.0°C. INPUT 1 OUTPUT 1 & 2 Pt100 + SERIAL COMMS. SUPPLY + + ELECTRICAL CONNECTIONS OUTPUT 3 N/C C N/O RELAY _ SSR +5V 6 7 8 9 10 GND OC2 5 11 OC1 4 PPI 12 L AC 3 HumiTherm-c 13 N DC 2 14 1 18 17 16 15 Ex - RH SENSOR INPUT 2 JUMPER SETTINGS OUTPUT-3 Output Type Jumper Setting - A Jumper Setting - B Relay SSR Voltage Pulses Jumper Setting-B Jumper Setting-A ENCLOSURE ASSEMBLY MOUNTING DETAILS OUTPUT-3 MODULE INPUT 1 OUTPUT 1 & 2 Pt100 + COSMERMISA.L SUPPLY `UP' inscribed on topside Plug & Socket Connector UP UP +5V OOCC21 6 5 4 3 2 1 H1ON7u_IE8PN/UxmCTPi1PC-PTU87UhTNTeI/2O1r396mRRS111111EHS140352LRSAEYNNL SOR AC DC Removal Bezel Placing Back PPI HumiTherm-c °C %RH1 2 AL2 TUN AL1 Front Label Pullout Grip Power Supply Board PPI HumiTherm-c Front Label Upright Output Module Projections Slots MOUNTING DETAILS SERIAL COMM. MODULE Power Supply Board Serial Communication Module Plug & Socket Connectors PPI -c iTherm Hum Front Label Upside-down WIRING CONNECTION RH SENSORS R=Red G= Green B=Black Ex - + 18 17 16 R B G (Humirel RH sensor) ( R LO- 38.4 R HI-153.6) Ex - 18 17 R B + 16 G (IST RH sensor) ( R LO- 0 R HI-100) Ex - 18 17 R B + 16 G (Capacitance RH sensor) ( R LO- 0 R HI-151.5)