AUTONICS M4N-DV-XX (01)
DRW170795AA
DIGITAL PANEL METER
M4N SERIES
INSTRUCTION MANUAL
Thank you for choosing our Autonics product. Please read the following safety considerations before use.
Safety Considerations
Please observe all safety considerations for safe and proper product operation to avoid hazards. Safety considerations are categorized as follows.
Warning Failure to follow these instructions may result in serious injury or death. Caution Failure to follow these instructions may result in personal injury or product damage. The symbols used on the product and instruction manual represent the following
symbol represents caution due to special circumstances in which hazards may occur.
Warning
1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in fire, personal injury, or economic loss.
2. Install on a device panel to use. Failure to follow this instruction may result in fire.
3. Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in fire.
4. Check 'Connections' before wiring. Failure to follow this instruction may result in fire.
5. Do not disassemble or modify the unit. Failure to follow this instruction may result in fire.
Caution
1. Use the unit within the rated specifications. Failure to follow this instruction may result in fire or product damage.
2. Use dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in fire.
3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in fire or explosion.
4. Keep metal chip, dust, and wire residue from flowing into the unit. Failure to follow this instruction may result in fire or product damage.
The above specifications are subject to change and some models may be discontinued without notice.
Be sure to follow cautions written in the instruction manual and the technical descriptions (catalog, homepage).

Ordering Information

M4N DV

01
Measuring input range

Power supply
Measurement functions
Measuring input Size Digit Item

DC volt input F.S. DC ampere input F.S.

1

199.9mV

199.9

2

1.999V

1.999mA

3

19.99V

19.99mA

4

199.9V

199.9mA

Blank Option

Option

0

5VDC

1

12-24VDC

V

Voltage

A

Current

I

Scaling(DC4-20mA)2

D

DC Type

N

DIN W48×H24mm

4

1999(3½ Digit)

M Meter

1: M4N series is to measure DC only. AC voltage and AC current is not available to be measured. 2: 1-5VDC measuring input is optional.

Specifications

Model Measurement function Power supply Allowable voltage range Power consumption Display method Max.display range Display accuracy Sampling cycle A/D conversion method Response time Max.allowable input Sampling time Insulation resistance Dielectric strength
Noise immunity

Vibra -tion

Mechanical Malfunction

Mechanical Shock
Malfunction Environ Ambient temperature -mnet Ambient humidity Unit weight

M4N-DV-

M4N-DA-

M4N-DI-

DC voltage

DC current

5VDC, 12-24VDC

DC4-20mA

90 to 110% of rated voltage

2W

7Segment LED Display(Character height: 10mm)

Max. 1999

F.S.±0.2% rdg ±1digit

300ms

Dual intergal method

Approx. 2sec(0 to 1999)

150% of measurement input range

2.5 times/sec

Over 100M(at 500VDC megger)

2000VAC 50/60Hz for 1 minute

±100V the square wave noise(pulse width: 1) by the noise simulator
0.75mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 1 hour
0.5mm amplitude at frquency of 10 to 55Hz in each X, Y, Z direction for 10 minutes

300m/s²(approx. 30G) in each X, Y, Z direction for 3 times

100m/s²(approx. 10G) in each X, Y, Z direction for 3 times

-10 to 50, storage: -20 to 60

35 to 85%RH, storage: 35 to 85%RH

Approx. 44g

Environment resistance is rated at no freezing or condensation.

Connections
SOURCE1

[Position of the decimal point]

INPUT

1

2

3

4

5

6

7

8

10³ 10² 10¹ COM LO

10

Hold

Dot

HI

1: 5VDC, 12-24VDC When changing the position of the decimal point, disconnect switching pattern point on PCB
and change the decimal point in external terminal socket. When "1" or "-1" is flashes with a certain measurement input, disconnect power supply and
then check the cables.

24 36

Dimensions 48 4

63

37

22

10

21

 Panel cut-out Min. 60

(unit: mm)

Min. 37

21.5

+0.5 -0

45.5

+0.5 -0

 48×24 Bracket

58

Mounting
Panel

19 63

Connections of Applications

Simultaneous connection of voltmeter and ammeter
1

Power of the load

A

Load

HI

LOW HI

LOW

Voltmeter

Ammeter

Max. 10.0mm
Panel boad tickness should be less than 10.0mm.

DC power

DC power

supply 1

supply 2

1: Compared to measurement input range, higher measuring voltage needs a multiplier and lower measuring voltage needs a shunt.
When using voltmeter and ammeter simultaneously, connect the separated power supply each.
(-) terminal of the power and (-) terminal of measurement input are shorted.

Cautions during Use
1. Follow instructions in 'Cautions during Use'. Otherwise, it may cause unexpected accidents. 2. 5VAC, 12-24VDC power supply should be insulated and limited voltage/current or Class 2,
SELV power supply device. 3. Install a power switch or circuit breaker in the easily accessible place for supplying or
disconnecting the power. 4. Keep away from high voltage lines or power lines to prevent inductive noise.
In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise.

Connection with the line filter

Connection with the varistor

110/ 220VAC

Install the line filter close to the panel meter
HI
Panel meter
LOW

110/ 220VAC

HI Panel meter LOW

Earth ground

5. This unit may be used in the following environments.

Indoors (in the environment condition rated in 'Specifications') Altitude max. 2,000m

Pollution degree 2

Installation category II

Major products

Photoelectric Sensors Temperature Controllers

Fiber Optic Sensors Temperature/Humidity Transducers

Door Sensors

SSRs/Power Controllers

Door Side Sensors Counters

Area Sensors

Timers

Proximity Sensors

Panel Meters

Pressure Sensors

Tachometer/Pulse (Rate) Meters

Rotary Encoders

Display Units

Connector/Sockets Sensor Controllers

Switching Mode Power Supplies

Control Switches/Lamps/Buzzers

I/O Terminal Blocks & Cables

Stepper Motors/Drivers/Motion Controllers

Graphic/Logic Panels

Field Network Devices

Laser Marking System (Fiber, Co, Nd: YAG)

Laser Welding/Cutting System

http://www.autonics.com
HEADQUARTERS: 18, Bansong-ro 513beon-gil, Haeundae-gu, Busan, South Korea, 48002 TEL: 82-51-519-3232 E-mail: sales@autonics.com
DRW170795AA

https://manual-hub.com/



References