Product Overview
This document provides details on CLAS Air Conditioning Leak Stop products, designed to seal leaks in automotive air conditioning systems. Two variants are available: CO 4065 for R134a refrigerant and CO 4070 for R1234yf refrigerant.
Product Identification
- CO 4065: STOP FUITE CLIMATISATION POUR R134a 30ml / AIR CONDITIONING LEAK STOP FOR R134a
- CO 4070: STOP FUITE CLIMATISATION POUR R1234yf / AIR CONDITIONING LEAK STOP FOR R1234yf
Attention and Warning
Attention: Before returning the product for any reason (installation issues, usage instructions, breakdown, manufacturing problem), please contact CLAS. Contact can be made via email at sav@clas.com, by phone at +33(0)4 79 72 92 80, or by visiting the website clas.com. If you have changed your mind about the purchase, return the product before attempting installation.
Warning: Similar to the attention notice, customers are advised to contact CLAS for any issues before returning the product. Contact details are provided for email, phone, and website.
Features
- Intended for automotive air conditioning circuits.
- Suitable for circuits up to 1.5 Kg of refrigerant gas.
- Does not contain R134a gas or propellant gas, compliant with regulation CE 842/2006.
- Vehicle must be equipped with a low-pressure connection.
- Net content: 30mL.
- Active product is a colorless to pale yellow liquid.
- Intended for professional use.
- Do not use in hermetically sealed systems.
- Recommended to use goggles and protective gloves during application.
Usage Instructions
- Recover the refrigerant gas from the A/C system. It is recommended to change the filter beforehand to remove moisture.
- Connect the A/C station and vacuum the system for 8 minutes.
- Check the vacuum level with a manometer.
- Turn off the vacuum pump and verify that the vacuum is maintained for at least 5 minutes.
- If the vacuum cannot be maintained for 5 minutes, the leak is too significant for the product to be effective.
- If the vacuum test is successful, disconnect the low-pressure (LP) quick coupling from the A/C system. Connect the leak stop product using the quick coupling (B) to the A/C system's low-pressure connection.
- Holding the product bottle upside down, press the button (A) until the liquid is sucked into the system (approximately 8-10 seconds). Disconnect the leak stop.
- Recharge the A/C system with the appropriate refrigerant gas and oil, following the vehicle manufacturer's instructions.
- Start the car and let it run for at least 20 minutes to allow the product to work and seal the leak.
Contact Information
CLAS Equipements
83 chemin de la CROUZA
73800 CHIGNIN
FRANCE
Tel: +33 (0)4 79 72 62 22
Fax: +33 (0)4 79 72 52 86
For components or parts, please contact the reseller. In case of problems, please contact your authorized technician.