User Manual and Specifications
This document is the user manual for the PeakTech 2715 Loop and PSC Tester. It provides essential information regarding safety precautions, operating instructions, device features, technical specifications, and battery replacement.
The PeakTech 2715 complies with EU directives 2014/30/EU (Electromagnetic Compatibility) and 2014/35/EU (Low Voltage).
Note: Read this manual carefully before use and make this manual available to subsequent users.
This device complies with EU Directives 2014/30 / EU (Electromagnetic Compatibility) and 2014/35 / EU (Low Voltage) as defined in Addendum 2014/32 / EU (CE Mark).
Overvoltage category III 600V; Pollution degree 2.
Category | Description |
---|---|
CAT I | Devices with low transient overvoltages or without direct connection to the mains (battery operated) or devices with safety extra-low voltage. |
CAT II | For devices with detachable plug connection to the power supply / socket, such as household appliances, power strips, portable tools, etc. |
CAT III | Permanently installed switches, circuit breakers, sockets or contactors or other distribution devices. |
CAT IV | Devices and equipment of low-voltage installation, e.g. Main switch at the current input, surge arrester, electricity meter and ripple control receiver. |
Symbol | Meaning |
---|---|
⚠️ | Caution: Refer to this manual before using the meter. |
⚡ | Dangerous voltages. |
⏏ | The tester is protected by double insulation or reinforced insulation. |
Refer to the diagram on page 15 for numbered parts.
(Diagram description: The front view of the PeakTech 2715 tester shows a digital display, several indicator lights (P-E, P-N, P-N REVERSE), a TEST button, and a rotary switch with positions for LOOP (20Ω, 200Ω, 2000Ω) and PSC (200A, 2000A, 20kA), plus an OFF position. The rear view shows a battery compartment with space for six AA batteries and a pothook.)
Connect the device to the circuit to be measured.
Before pressing the "Test" button, check the status of the 3 LEDs:
Status LED | P-E | P-N | P<-N | Action |
---|---|---|---|---|
Correct wiring | ● (On) | ● (On) | ○ (Off) | Start measurement |
Not connected | ○ (Off) | ○ (Off) | ○ (Off) | Check connection |
Ground missing | ○ (Off) | ○/● (On/Off) | ○ (Off) | Check connection |
Phase/Neutral reversal | ○/● (On/Off) | ○/● (On/Off) | ● (On) | Reverse connection |
Legend: ● On, ○ Off, ○/● On or Off
If the indicating light status is not as above, do not test and check the wires again.
When the tester is connected to the power, the LCD will update the voltage (P-E) per second. Do not test if the voltage is unusual or not as expected.
The tester should only be used in AC230V (50Hz) systems.
Turn the tester to the 20Ω, 200Ω, or 2000Ω range. Press the TEST button. The LCD will display the value and unit. The tester beeps once when the test is finished.
To get better values, turn the tester to the lowest range possible. If the LCD flashes ?️ [temperature symbol], disconnect the tester, switch it off, and let it cool down.
Turn the tester to the 200A, 2000A, or 20kA range. Press the TEST button. The LCD will display the value and unit. The tester beeps when the test is finished.
To get better values, set the tester to the lowest range possible. If the LCD flashes ?️ [temperature symbol], disconnect the tester, switch it off, and let it cool down.
If there is an RCD or fuse in the circuit, it should test loop impedance.
(Diagram description: A schematic shows a power supply with lines L1, L2, L3, PEN, and PE connected to a load. It illustrates the TNC and TNS earthing systems and indicates the loop impedance (Zs) and earth resistance (Ro) paths.)
According to IEC 60364, every loop should meet the formula: Ra ≤ 50/Ia
When the protection device is an RCD, Ia is the rated residual current I∆n.
I∆n [mA] | 10 | 30 | 100 | 300 | 500 | 1000 |
---|---|---|---|---|---|---|
Ia(50V) [Ω] | 5000 | 1667 | 500 | 167 | 100 | 50 |
Ia(25V) [Ω] | 2500 | 833 | 250 | 83 | 50 | 25 |
According to IEC 60364, every loop should meet the formula: Zs ≤ Uo/Ia
When the protection device is a Fuse, Uo=230V, Ia and Zsmax:
Rated Current [A] | Break time (5s) | Break time (0.4s) | ||
---|---|---|---|---|
Ia(A) | Zs(Ω) | Ia(A) | Zs(Ω) | |
6 | 28 | 8.2 | 47 | 4.9 |
10 | 46 | 5 | 82 | 2.8 |
16 | 65 | 3.6 | 110 | 2.1 |
20 | 85 | 2.7 | 147 | 1.56 |
25 | 110 | 2.1 | 183 | 1.25 |
32 | 150 | 1.53 | 275 | 0.83 |
40 | 190 | 1.21 | 320 | 0.72 |
50 | 250 | 0.92 | 470 | 0.49 |
63 | 320 | 0.71 | 550 | 0.42 |
80 | 425 | 0.54 | 840 | 0.27 |
100 | 580 | 0.39 | 1020 | 0.22 |
Prospective short current must be bigger than Ia.
Accuracies are specified as follows: ± (...% of reading +...digits) at 23°C ± 5°C, below 80% RH.
Range | Resolution | Test times | Full scale accuracy |
---|---|---|---|
20Ω | 0.01Ω | 25A/20ms | ± 2% of F.S ± 5 dgt. |
200Ω | 0.1Ω | 2.3A/40ms | ± 2% of F.S ± 5% |
2000Ω | 1Ω | 15mA/280ms | ± 2% of F.S ± 5 dgt. |
Range | Resolution | Test times | Full scale accuracy |
---|---|---|---|
200A | 0.1A | 2.3A/40ms | ± 2% of F.S ± 5 dgt. |
2KA | 1A | 25A/20ms | ± 2% of F.S ± 5 dgt. |
20KA | 10A | 25A/20ms | ± 2% of F.S ± 5 dgt. |
Range | Full scale accuracy |
---|---|
50~250V | ± 2% of F.S ± 5 dgt. |
When the low battery symbol ? [battery symbol] appears on the LCD, the six 1.5V 'AA' batteries must be replaced.
(Diagram description: The rear of the tester is shown with the battery compartment open, indicating the correct placement and polarity for six AA batteries.)
The delivery of many devices includes batteries, which for example serve to operate the remote control. There also could be batteries or accumulators built into the device itself. In connection with the sale of these batteries or accumulators, we are obliged under the Battery Regulations to notify our customers of the following:
Please dispose of old batteries at a council collection point or return them to a local shop at no cost. The disposal in domestic refuse is strictly forbidden according to the Battery Regulations. You can return used batteries obtained from us at no charge at the address on the last side in this manual or by posting with sufficient stamps.
Contaminated batteries shall be marked with a symbol consisting of a crossed-out refuse bin and the chemical symbol (Cd, Hg or Pb) of the heavy metal which is responsible for the classification as pollutant:
??️ [crossed-out bin] ? [cadmium symbol] (Cd¹), ⚖️ [mercury symbol] (Hg²), ⚖️ [lead symbol] (Pb³)
1. "Cd" means cadmium.
2. "Hg" means mercury.
3. "Pb" stands for lead.
All rights, also for translation, reprinting and copy of this manual or parts are reserved. Reproduction of all kinds (photocopy, microfilm or other) only by written permission of the publisher.
This manual considers the latest technical knowing. Technical changings which are in the interest of progress reserved.
We herewith confirm, that the units are calibrated by the factory according to the specifications as per the technical specifications. We recommend to calibrate the unit again, after 1 year.
© PeakTech® 06/2021 Ehr/Ham/Ehr
File Info : application/pdf, 20 Pages, 1.41MB
DocumentDocument![]() |
PeakTech 2710 Digital RCD Tester - User Manual User manual for the PeakTech 2710 digital RCD tester, detailing safety instructions, device operation, technical specifications, battery replacement, and regulatory information. |
![]() |
PeakTech 1096 AC/DC Voltage Tester - Operation Manual Comprehensive operation manual for the PeakTech 1096 AC/DC Voltage Tester, detailing its features, safety precautions, operation, and specifications for electrical testing. |
![]() |
PeakTech 3432 Fuse Finder and RCD Tester - User Manual Comprehensive user manual for the PeakTech 3432 Fuse Finder and RCD Tester, detailing safety precautions, operation, controls, specifications, and battery handling. Includes non-contact voltage testing and RCD testing functions. |
![]() |
PeakTech 2710 RCD Tester Manual and Specifications User manual for the PeakTech 2710 RCD Tester, detailing safety instructions, device operation, wiring tests, technical specifications, and battery handling. Essential guide for electrical testing professionals. |
![]() |
PeakTech 2530 3-Phase Rotation Tester Operation Manual Operation manual for the PeakTech 2530 3-Phase Rotation Tester, detailing safety precautions, technical specifications, instrument layout, operating conditions, measurement procedures, and cleaning instructions for electrical testing. |
![]() |
PeakTech 2720 Portable Appliance Tester User Manual Comprehensive user manual for the PeakTech 2720 Portable Appliance Tester, detailing safety instructions, device operation, test procedures for various appliance classes, and technical specifications. Learn how to safely and effectively test portable electrical devices. |
![]() |
PeakTech 2720 Portable Appliance Tester User Manual User manual for the PeakTech 2720 Portable Appliance Tester, detailing safety instructions, device controls, operation, specifications, and battery replacement. |
![]() |
PeakTech 2680 A / 2685 A: Hochspannungs-Isolationstester Bedienungsanleitung Umfassende Bedienungsanleitung für die Hochspannungs-Isolationstester PeakTech 2680 A und 2685 A. Erfahren Sie mehr über Funktionen, Sicherheitshinweise, Messverfahren und technische Spezifikationen für präzise Isolationsprüfungen. |