Installation Guide for VIESSMANN models including: VITOTRON 100 VLN2 Wall Mounted Electric Boiler, VITOTRON 100, VLN2 Wall Mounted Electric Boiler, Mounted Electric Boiler, Electric Boiler

View flyer

Vitotron 100 wall-mounted electric boiler | Viessmann US

Flyer PDF 4 MB

Installation manual

Vitotron VLN2-06 — TanklessWaterHeaters


File Info : application/pdf, 4 Pages, 4.11MB

PDF preview unavailable. Download the PDF instead.

Vitotron100 11.08.2022 US ?v=10251445569839077896
WALL-MOUNTED ELECTRIC BOILER
Heating without fossil fuels, for residential applications VITOTRON 100, VLN2
Plug-and-play electric heating The Vitotron 100 makes its mark through simple installation, safe operation and convenient control.

WALL MOUNTED ELECTRIC BOILER
The Vitotron 100 is the easiest way to add hydronic space heating to new and existing systems, with a space saving design and integrated components for a fast and simple installation.

Vitotron 100, VLN2 electric boiler is an environmentally responsible and efficient heating source.

Aesthetically pleasing and easy to install The compact profile and integrated control unit of the Vitotron 100, VLN2 electric boiler make it a welcome addition to any space. With efficient operation and advanced controls, the Vitotron 100 offers superior design, perfect for low temperature heating in space restrictive areas like closets and small mechanical rooms.
Without venting and gas connections, the small plug-andplay device can be installed practically anywhere. Installing the Vitotron 100, VLN2 electric boiler does not require a gas connection, chimney or boiler room ­ all that is needed is a power source.
The weather-compensated control unit utilizes an outdoor temperature sensor, and heating curves ensure effective control by automatically adjusting the water temperature according to the outside temperature. The heating curves and operating efficiencies up to 99.4% ensure energy savings far above typical electric space heating.

temperature reset sensor with a thermostat start/stop control and fixed set-point. Both the internal circulator and an external circulating pump can be powered directly from the boiler.
Low maintenance and perfect for small vacation homes and additions When an electric boiler is used to generate heat, the risk of system freezing due to long absences is eliminated. The Vitotron 100 automatically switches on when the temperature falls below an individually set minimum temperature, allowing it to keep the room in a comfortable temperature range. Automatic outdoor temperature sensor and warm weather shutdown can be used to keep remote locations warm without using excess energy.

The Vitotron 100 comes with a 1.32 Gal (5 L.) diaphragm expansion vessel. The VLN2 can be used with an outdoor

Easy-to-use control unit

Heat storage The use of an electric boiler in conjunction with a hot water buffer cylinder ensures convenient and inexpensive heating with relatively low system costs. The VLN2 can be used as a backup to a heat pump or used to maintain a storage tank to take advantage of off-peak utility rates. The boiler features an external shutdown input which can be used in conjunction with hybrid systems and utility Home Energy Management Systems.
The VLN2 is also a perfect partner for photovoltaic systems and as a backup to solar thermal systems. This allows the boiler to be operated even more costeffectively, as priority is given to using the available, self-generated energy from the roof. The combination of heat storage and free energy from a photovoltaic system enables very low running costs.

VITOTRON 100 13.6 - 49.1 MBH 4.0 - 14.4 kW
The Vitotron 100 is perfect for well insulated homes and can also be installed in dual fuel application such as cold climates where gas backup is necessary.

PRODUCT FEATURES
+ Electric boiler with 4 to 14.4 kW rated output + Boiler for central heating only + All models use a thermostat for start/stop; outdoor
reset can be used in addition
+ Actual efficiency of 99.4 %
BENEFITS AT A GLANCE
+ Using the control unit, the water temperature in the
heating zone can be set to between 85°F and 140°F (29.4°C and 60°C)
+ Automatic modulation of the heating output
according to the heat demand
+ Fits in small spaces and can be utilized as a backup
or as a primary low temp heat source
+ The weather-compensated control unit ensures
energy efficient boiler operation through automatic adjustments to reflect changes in the outside temperature

1 2

3

4

5

6

VITOTRON 100, VLN2
1 Modulating instantaneous submersible heating elements
2 Safety temperature limiter 3 Thermostat controlled and weather-
compensated control unit 4 High efficiency pump 5 Pressure sensor 6 Safety valve

Technical Information VITOTRON 100, VLN2

Viessmann Manufacturing Company (US) Inc. Warwick, RI (800) 288-0667 viessmann-us.com

Boiler Rated Power
Voltage Rated Current Breaker Quantity Amps Heating Elements Element Resistance / each Weight Overall dimensions Depth
Width
Height Minimum Flow Rates

kW Btu/h V A A Qty  Lbs. kg
Inches mm Inches mm Inches mm gpm

VLN2-04 4
13,652 240
16.66 1 @ 30 amp
3 43.3 68.5
31
9 251
17 432
28 711 1.1

VLN2-06 6
20,478 240 25.0
1 @ 40 amp 3
28.8 68.5
31
9 251
17 432
28 711 1.32

VLN2-08 8
27,304 240 33.3
1 @ 50 amp 3
21.6 68.5
31

VLN2-12 12
40,956 240 50.0
1 @ 60/70 amp 3
14.4 68.5
31

9

9

251

251

17

17

432

432

28

28

711

711

1.32

1.32

VLN2-14.4 14.4
49,147 240 60.0
1 @ 80 amp 3
12.0 68.5
31
9 251
17 432
28 711 1.32

Technical information subject to change without notice. Printed in USA 11/22



References

Adobe PDF Library 17.0 Adobe InDesign 18.0 (Macintosh)