Product Models
Models include:
- LZR430RGB (15-1567N)
- LZR200R (15-1038N)
- LZR60G (15-1029N)
- LZR80B (15-1561N)
- LZR300B (16-2165)
- LZR250RGY (15-1564N)
- LZR150G (15-2160)
- LZR250PINK (15-1565)
Professional Use & Safety
This laser is for professional use only, compliant with EN60825-1:2014. Installation and operation require a skilled technician aware of laser dangers.
Key Safety Reminders:
- Class 3 & 4 lasers are for outdoor use only.
- No laser shooting towards the audience in public areas, unless a 5m safety radius is marked.
- Public area is defined as 3m above audience space and 2.5m width around it.
- Laser must be installed out of audience reach, at least 3m above ground, or protected by a 5m radius safety perimeter.
- Secure installation to prevent movement from vibrations or wind.
General Safety Instructions
Warning: Unit contains high-power laser devices. Do not open the housing to avoid exposure to unsafe laser radiation, which can cause blindness, skin burns, and fires.
- Keep this guide for future reference.
- Ensure correct voltage connection.
- For indoor use only.
- Unit must be earthed.
- Protect from rain/moisture; keep away from flammable materials.
- Ensure adequate ventilation (at least 50cm from surfaces); do not block vents.
- Disconnect power before servicing or replacing fuses; use identical fuse types.
- Secure with a safety chain; do not carry by the head.
- Maximum ambient temperature: 40°C (104°F).
- Stop use immediately in case of serious operating problems. Do not attempt self-repair. Contact authorized service.
- Do not connect to a dimmer pack.
- Ensure power cord is not crimped or damaged.
- Never disconnect by pulling the cord.
- Avoid direct eye exposure to the light source.
Disconnect Device: MAINS plug or appliance coupler must remain readily operable.
Laser Emission Data
Measured under IEC conditions:
Laser Classification | Value |
---|---|
Red Laser Medium | LD GaAIAs 638nm, typical |
Green Laser Medium | DPSS Nd:YVO4, 532nm |
Blue Laser Medium | LD GeAs 445nm, typical |
Beam Diameter | <5mm at aperture |
Pulse Data | All pulses < 4Hz (>0.25sec) |
Divergence (each) | <2 mrad |
Divergence (total light) | <90 degrees |
Laser Power Specifications
- LZR430RGB: 200mW-R-650nm +80mW-G-532nm +150mW-B-450nm
- LZR250RGY: 200mW-R-650nm +50mW-G-532nm
- LZR300B: 300mW-B-450nm
- LZR80B: 80mW-B-450nm
- LZR150G: 150mW-G-532nm
- LZR60G: 60mW-G-532nm
- LZR200R: 200mW-R-650nm
- LZR250PINK: 100mW-R-638nm; 150mW-B-445nm
Technical Specifications
Specification | Value |
---|---|
Mains Input | AC100-240V, 50/60Hz |
Fuse | 250V 2A Slow Blow (20mm Glass) |
Total Power | 20W |
Music Control | Internal microphone |
Laser Safety Standard | EN60825-1 2014 |
Condition Temperature | 10~40°C |
DMX Connections | 3 pins XLR Male/Female |
DMX Channels | Max 9 channels |
Measurement | 250 x 210 x 105mm |
Weight | 1.5 Kg |
Installation
Mount unit via bracket screw holes. Ensure firm fixing to prevent vibration/slipping. The supporting structure must be secure and able to support 10x the unit's weight. Use a safety cable rated for 12x the unit's weight.
Controls & Functions
The rear LED display shows current mode or DMX address. Settings and DMX addresses can be easily changed via the control panel. New settings appear after reset/save on next power-on.
- FUNC: Mode/Function: Set laser operating mode.
- ENTER: Confirmation: Confirm settings/changes.
- UP/DOWN: Change mode, parameter, or DMX address.
Operation Modes
Stand Alone Preprogrammed Laser Show
- Press FUNC to enter MODE OPTION.
- Use UP/DOWN to select desired Stand Alone mode.
- Press ENTER to confirm.
The laser operates in stand-alone mode. Each power-on recalls the last confirmed show. In MODE OPTION, the chosen show flashes. Select from 21 preprogrammed shows using UP/DOWN.
Master/Slave Mode
- Press FUNC to enter MODE OPTION.
- Use UP/DOWN until "SLAV" is displayed.
- Press ENTER to confirm.
In SLAVE MODE, connect MASTER and SLAVE units with a DMX cable. SLAVE units mirror the MASTER.
DMX Mode
- Press FUNC to enter MODE OPTION.
- Use UP/DOWN until "D001" is displayed.
- Press ENTER to confirm.
In DMX MODE, change the DMX address using UP/DOWN buttons.
Remote Control
Functions:
- 1. AUTO Show
- 2. MUSIC show
- 3. Laser ON/OFF
- 4. Color
- 5. Changing Pattern
- 6. Fixed pattern (1-128)
- 7. Pattern repetition
Button Functions
Button | Function | Description |
---|---|---|
ON/OFF | ON/OFF | REMOTE mode: Laser ON/OFF. Stand-alone modes (except SLA): Press twice for REMOTE mode. |
AUTO | AUTO | Automatic show 1/2 |
MUSIC | MUSIC | SOUND activated show 1/2. Blue LED flashes on sound detection. |
COLOR CHANGING | Cycle through programmed colors. | |
PATTERN CHANGING | Display and change patterns. | |
FIXED PATTERN | Choose pattern 1-128. | |
PATTERN REPEAT | Repeats last and current pattern. | |
PATTERN ID | Choose pattern via 1/2/3 digital ID. |
DMX Protocol
CHANNEL | DMX | CONTROL |
---|---|---|
CH 1 CONTROL MODE | 000-063 | BLACK OUT |
063-127 | AUTO SHOW | |
128-191 | MUSIC SHOW | |
192-255 | DMX MODE | |
CH2 GOBOS | 0-255 | Split 32 patterns |
0-127 | 100%-5% | |
CH3 ZOOM | 128-169 | Zoom out |
170-209 | Zoom in | |
210-255 | Zoom out and in | |
000-127 | 0-359 Degree | |
CH4 LEFT RIGHT TURN | 128-255 | Clockwise Mode |
192-255 | Anticlockwise Mode | |
000-127 | 0-359 Degree | |
CH5 UP DOWN TURN | 128-191 | Clockwise Mode |
192-255 | Anticlockwise Mode | |
000-127 | 0-359 Degree | |
CH6 ROTATE | 128-191 | Clockwise Mode |
128-255 | Anticlockwise Mode | |
000-127 | Left Right position (128 total) | |
CH7 LEFT RIGHT MOVE | 128-191 | Clockwise Move Mode |
128-255 | Anticlockwise Move Mode | |
000-127 | Up Down position (128 total) | |
CH 8 UP DOWN MOVE | 128-191 | Clockwise Move Mode |
128-255 | Anticlockwise Move Mode | |
000-015 | Original color | |
CH9 COLOR | 016-063 | Static color |
064-149 | JUMP COLOR | |
150-255 | LOOP COLOR |
Single color may have no effect.
Environmental Information
IMPORTANT NOTE: Do not dispose of electric products with household waste. Recycle them at designated centers. ♻️
Multilingual Content
This manual is also available in French, German, Slovenian, Spanish, Dutch, and Romanian, covering safety and operational details.