2

H2O Moisture Owner's Manual Table of Contents

Introduction Tools Needed Moisture Disc Installation Reference Chart Installation of Applicator
Installation of Moisture Sensor Pads and Discs Option A Option B Option C Option D Option E Option F Option G
End of Bale Sensor Installation ­ 200FCA (Optional) Control Box Installation Dye Marker Installation ­ 200DM (Optional) Wiring Diagram Downloading H2O App Screen Definitions
Main Screen Settings Screen Operation Reading Moisture Moisture Range Fixed Chamber Balers Only Dye Sprayer System Dye Sprayer Override H2O Firmware Update through App Pin Outs Parts Breakdown Installation Option A Installation Option B  G Fixed Chamber End of Bale Sensor Kit Precision Moisture Dye Marker Warranty Statement

Page 3 3 4
5-12 5-11
5 6 7 8 9 10 11 12 12 13 14 15 15 15 15 16-18 16 16 16 17 17 18 19 20-22 20 21 21 22 23

Introduction Congratulations and thank you for purchasing a Harvest Tec H2O Moisture Sensing Kit Model 201RB system. Please read this manual carefully to ensure correct steps are taken to attach the system to the baler. This system is designed to read moisture at levels of 5-60%.

Requirements

The app will support operation of the current operating system and one previous version for both Apple and Android devices.

**It is recommended for proper communication that the original phone/tablet power cable is used. Many lower cost power
cables do not meet requirements to properly charge and communicate to the Harvest Tec H2O module.

Tools Needed SAE wrench set Standard screw driver Side cutter

Hammer Measuring tape SAE socket set
3

Drill bit set Center punch

Moisture Disc Installation Reference Chart

Use this chart to identify the correct moisture disc installation instructions for each baler model.

Baler Make AGCO
CaseIH
Challenger Claas
Hesston
John Deere
Krone Kubota Kuhn McHale Massey Ferguson
New Holland
New Idea Vermeer
Vicon Welger

Baler Model
5134, 5415, 550 5446, 5446 Silage, 5456, 5545, 5545 Silage, 5546, 5546 Silage, 5556, 5556 Silage, 2745, 2746, 2746A, 2756A, 2766 2846, 2846A, 2856, 2856A, 2946, 2946A, 2956, 2956A 8400 Series, RB444, RBX 442, 443, 451, 461, 561 RB 454,464, RBX 452, 453, 462, 463 RB 554, 564, RBX 552, 553, 562, 563, 564 RB 455, 465, 560, 565 RB455A Utility Baler RB 34, 44, 45, 452 RB 46, 56 RB 453, 453A, 463, 463A, 563, 563A, RB 56C, RB56CA Rollant Fixed Chamber, Variant Balers 500 Series: 530, 540, 545, 550, 555S, 555T, 560, 565A, 565T, 700 Series - 730, 740, 745, 5400, 5500, 5600, 5800, Series Fixed Chamber, 814 Fixed Chamber 800 Series - 845, 846A, 855, 856, 900 Series - 946, 955, 956 430, 510, 530 435, 455, 465, 535, 545, 565, 446, 456, 466, 546, 566, 447, 457, 467, 547, 557, 567 448, 458, 468, 558, 568, 449, 459, 459E, 469, 559, 569, 440, 450, 460, 550, 560 440, 450, 460, 550, 560 w/HC2 960, 990 582 Silage Special, 854 C451R, V451R, V461R Round Pack Fixed Chamber, 1250, 1250 Multi-Cut, 1550, 1550 Multi-Cut, KR 125, F130, Vario Pack, 1510, 1810, Comprima Series BV4160, BV4180, BV4580, BV5160 VB 2160, 2190, VB 2255, 2260, 2265, 2285, 2295 V660, F540, F550, F560, Fusion Balers 1734, 1745, 1746, 1756 2745, 2746, 2746A, 2756A, 2766 2846, 2846A, 2856, 2856A, 2946, 2946A, 2956, 2956A RB4100V 544, 548, 564, 630, 634, 638 640, 644, 648, 650, 658 ,660, 664, 668, 678, 688 BR 7060, 7070 BR 7080, 7090 BR 730, 730A, 7050 BR 740, 740A, 750, 750A BR 770, 770A, 780, 780A Roll Belt 450, 460, 550, 560, 565 BR450 Utility Baler RF 440, 450 Fixed Chamber 4800 Series Fixed, 6343, 6344, 6345, 6364, 6365, 6454, 6464, 6465 404, 504 Series 1 Pro 404, 504 Series 2 Pro 604 Series 3 Pro 504, 505 J, K, M, N, Series, Rebel Series, XL Series 604M, 605M, 604N, 605N, 504R RF Fixed Chamber 119, 2121, 2125, 2235, RV 1601, 1901, 2160, 2190 RP Fixed Chamber 202, 220, 235, 245, 415, 420, 445, 520, 535

Install Option
B
E
F B B B A A B E F B
B
E B C C C G D G
B
A B B B E F B B B B B B B B A A C B B B B B B B B

4

Option A ­ Installation of Moisture Sensor Pads and Discs
*Refer to Moisture Disc Installation Reference Chart to locate correct install option
1. Open rear tail gate of baler and lock in the up position. Refer to baler manual to lock door open. 2. Remove bale shaping discs on each side of chamber. 3. Place plastic isolator (006-4641FX) in the same spot that the shaping disc had been. There should be a
hole in the baler that matches up with the hole in the plastic isolator, this hole will need to be drilled out to 3/4" (19mm). If there is not a hole, use the isolator as a template and mark the hole. Center punch the hole and drill it to 3/4" (19mm). Note: before drilling make sure you are not drilling into sensitive equipment on the outside of the baler). Repeat for other side of the baler. 4. Insert plastic bushing (006-4641G) from the outside of baler. Make sure it is flush with the outside of the baler frame. Go to the inside of the baler and mark amount that protrudes into the chamber. Remove and cut off excess material. Repeat for other side. 5. Using the 4" carriage bolt slide the parts on in following order: metal disc (001-4641HX), plastic isolator (006-4641FX) and shortened plastic bushing (006-4641G). 6. Insert disc assembly into 3/4" (19mm) hole from inside of bale chamber. Secure to outside of baler by attaching to the protruding carriage bolt in the following order: small isolator (006-4641I), 1/2" D shaped washer, 1/2" lock washer, 1/2" nut. Tighten down and repeat for the other side. Make sure no part of the bolt or hardware makes contact with the frame of baler-no metal to metal. Trim 006-4641I to fit. 7. Route moisture harness (006-2470RB) from drawbar down to the carriage bolt on each side. Make sure it does not come in contact with any moving parts. Secure with cable ties. 8. Attach moisture cable to moisture carriage bolt by placing items in the following order: 1/2" D shaped washer, Ring terminal of moisture harness (006-2470RB), second 1/2" D washer, 1/2" lock washer, 1/2" nut. Tighten down and repeat for other side. Make sure none of the hardware contacts the frame of baler.
5

Option B - Installation of Moisture Sensor Pads and Discs
*Refer to Moisture Disc Installation Reference Chart to locate correct install option
2" from back of chamber (51mm)

Figure 1
1" from top of roll (25mm)

1. If your baler is equipped with bale shaping pads, remove disc and use existing hole (may need to be drilled larger, 3/4" (19mm) to install new moisture sensing discs.
2. If your baler is not equipped with bale shaping pads you will need to drill a hole in the chamber directly behind and above the starting roll (Figure 1).
3. The mounting hole will be 3/4" (19mm) in diameter. Use a plastic pad (006-4641F) and place it into the baler to use as a template. The bottom edge of the pad will be placed 1" (25mm) up from starting roll and 2" (51mm) from the back of the bale chamber (Figure 1).

006-4641G (a) 006-2470RB

006-4641G (b)
006-4641I

006-4641H
006-4641F
4. Locate the 006-4641G (a) piece, this will need to be cut down to size. Use the already machined line in the bushing to cut off the small piece shown above 006-4641G (b). Part 006-4641I may also need to be trimmed to fit.
5. Depending on the baler the bolt may need to be trimmed for proper fit. 6. Tighten all of the hardware to 50 ft/lbs (68 N/m). 7. Make sure that the plastic pad is protecting all metal surfaces of the disc from touching baler. 8. Run the moisture wire harness (006-2470RB) to each disc securing with cable ties.

6

Option C - Installation of Moisture Sensor Pads and Discs
*Refer to Moisture Disc Installation Reference Chart to locate correct install option
A

Figure 2

1/4" in from back of baler (7mm)

Figure 1

1" from Bottom (25mm)

1. Both moisture discs (006-4641H) will need to be cut along the serrated line (A) shown on Figure 1. Only cut on the line shown on Figure 1, do not cut the other line.
2. The plastic pad (006-4641F) will also need to be cut 1/4" (7mm) longer than the back of the disc. 3. Using the cut disc as a pattern, mark and drill a 3/4" (19mm) hole in the side of the bale chamber. The disc
will need to be placed on the baler 1" (25mm) up from bottom and 1/4" (7mm) in from the back of the chamber (Figure 2).

006-2470RB

006-4641G 006-4641I

006-4641H 006-4641F

4. Make sure that plastic pad is protecting all metal surfaces of disc from touching baler. 5. Run the moisture wire harness (006-2470RB) to each disc securing with cable ties. 6. On some balers the bolt may need to be trimmed for proper fit. 7. Tighten all hardware to 50 ft/lbs (68 N/m). 8. Apply silicone over nuts and washers.
7

Option D - Installation of Moisture Sensor Pads and Discs
*Refer to Moisture Disc Installation Reference Chart to locate correct install option
B A

Figure 2

Figure 1
C
1. The moisture discs (006-4641H) will both need to be cut on line A. (Figure 1) One disc will need to be cut on line B and one disc on line C.
2. The plastic pad (006-4641F) will also need to be cut 1/4" longer than the back of the disc. 3. Bevel all sides of the cut discs to allow the smooth travel of crop over them. 4. The mounting hole will be 3/4" (19mm) in diameter. The disc will need to be placed on the baler lining up
the center of the bolt with the location 2" (51mm) up from bottom and 2" in from the back of the chamber. (Figure 2)

006-2470RB

006-4641G 006-4641I

006-4641H 006-4641F

5. Make sure that plastic pad is protecting all metal surfaces of disc from touching baler. 6. Run the moisture wire harness (006-2470RB) to each disc, securing with cable ties. 7. On some balers the bolt may need to be trimmed for proper fit. 8. Tighten all hardware to 50 ft/lbs (68 N/m). 9. Apply silicone over nuts and washers.
8

Option E - Installation of Moisture Sensor Pads and Discs
*Refer to Moisture Disc Installation Reference Chart to locate correct install option
1. If your baler is equipped with bale shaping pads, remove pads and use existing hole (may need to be drilled larger) to install new moisture sensing discs.
2. If your baler is not equipped with bale shaping pads you will need to drill a hole in the chamber directly behind and above the starting roll (Figure 1).
3. You will need to remove the main chain assembly to install the disk on the right side of baler (when facing front of baler) Figure 2.
4. The hole size is 3/4" (19mm) diameter. Before drilling the hole make sure hole is accessible from opposite side of chamber to tighten down mounting hardware and to install moisture harness (Figure 3).

Figure 1

Figure 2

Figure 3

Figure 4

006-2470RB

006-4641G

006-4641I

006-4641H 006-4641F

5. Locate the 006-4641G. The piece will need to be cut down to size. 6. Use the already machined line in the bushing to cut off the small piece shown above. 7. Depending on the baler the bolt may need to be trimmed for proper fit. 8. Tighten all of the hardware to 50 ft/lbs (68 N/m). 9. Make sure that the plastic pad is protecting all metal surfaces of the disc from touching baler (Figure 4) 10. Run the moisture wire harness (006-2470RB) to each disc securing with cable ties. 11. Apply silicone over nuts and washers.

9

Option F - Installation of Moisture Sensor Pads and Discs
*Refer to Moisture Disc Installation Reference Chart to locate correct install option
1. Both moisture discs (006-4641H) will need to be cut along the serrated line (A) shown on Figure 1. Measure from the laser etched line (B) 1 3/4" (45mm) on both side. Mark and cut the disc. A completed disc in shown to the right.
2. The plastic pad (006-4641F) will also need to be cut 1/4" (7mm) larger than the steel disc. 3. Bevel all sides of the cut discs to allow the smooth travel of crop over them.
B C Figure 1
A
4. Mark a line 1 1/2" (38mm) up and 3 1/2" (89mm) over from point (D). Drill a 3/4" hole at the point (E). Repeat for the opposite side.
D E
Figure 2
5. Locate the 006-4641G. The piece will need to be cut down to size. Use the already machined line in the bushing to cut off the small piece shown above.
6. Depending on the baler the bolt may need to be trimmed for proper fit. 7. Tighten all of the hardware to 50 ft/lbs. 8. Make sure that the plastic pad is protecting all metal surfaces of the disc from touching baler. 9. Run the moisture wire harness (006-2470RB) to each disc securing with cable ties. 10. Apply silicone over nuts and washers.

006-4641G

006-2470RB

006-4641I

10

006-4641H 006-4641F

Option G - Installation of Moisture Sensor Pads and Discs
*Refer to Moisture Disc Installation Reference Chart to locate correct install option

Measure 5 1/8" from this point,
toward top of
the baler

Figure 1

Figure 2

4. With the baler door open measure 5 1/8" toward top of baler from the point shown in figure 1. Drill a 3/4" (19mm) hole to mount moisture disc as shown in figure 2.
5. Use plastic pad (006-4641F) and place it into the baler to use as a template. The bottom edge of the pad
will be placed 2" (51mm) up from bottom of sheet metal on door and starting roll and 1" (25mm) back from sheet metal seam in figure 2.

006-4641G 006-4641I 006-2470RB

006-4641H
006-4641F
6. Locate part 006-4641G, which will need to be cut down to size. Use the factory machined line in the bushing to cut off the small piece shown above.
7. Depending on the baler the bolt may need to be trimmed for proper fit. 8. Tighten all of the hardware to 50 ft/lbs (68 N/m) 9. Make sure that the plastic pad is protecting all metal surfaces of the disc from touching baler. 10. Run the moisture wire harness (006-2470RB) from the drawbar to each disc, securing with cable ties. Be
harness is clear from moving parts, chains and potential pinch points. 11. Apply silicone over nuts and washers to seal moisture way from connections.
11

End of Bale Sensor Installation ­ 200FCA (Optional)
*This sensor is required on Fixed Chamber balers and Optional on all other Models (Kit 200FCA)
The end of bale sensor is used to determine when the baler door is open. With this information the system is able to show the average moisture of the previous bale.
Locate the sensor (006-7400) and the sensor bracket (001-4648RB). On the right side of the baler find a location 1"­ 6" down from the hinge to mount the bracket. Check for clearance with hydraulic cylinders before mounting the bracket. The bracket should be mounted to the front side of the hinge point, with the sensor aligned over the back door.
Mark and drill two 1/4" (7mm) holes and install the bracket using two 5/16" x1/4" self-tapping bolts. Install the sensor into the bracket and leave 1/4" (7mm) of clearance between the end of sensor and the door.
The harness will need to be routed toward the harness at the tongue of the baler. Secure with cable ties and take care to avoid pinch points. The harness extension (006-7400EXT) may need to be used.

Hinge Point

006-7400

Back Door Control Box Installation

001-4648RB

View of the right side of baler

Front of baler

Locate a safe location in the cab of the tractor to place the control box (006-2473RB) in a location to connect a USB cable ending in a USB-A plug to connect to display device.

Connect the Power Harness (006-2470P) and the Baler Power Communication Harness (006-2470RB).

The control box (006-2473RB) is equipped with a green light to indicated both power and connection.

Plug the tablet/phone cord into the communication port (closest to light) and indicated by:

006-2473SB

Slow Blink ­ System has power but not connected to phone or tablet.

Solid Green ­ Device is connected.

**It is recommended for proper communication that the original phone/tablet power cable is used. Many lower cost power cables do not meet requirements to properly charge and communicate to the Harvest Tec H2O module. Use of adapters is not supported.
12

Dye Marker Installation ­ 200DM (Optional) Locate the dye marking kit tank and pump assembly (005-9015). Identify a suitable mounting location for the tank away from moving parts and hydraulic lines on the baler. Be sure to mount the tank within 10' of the connection on the Baler Pwr/Comm Harness (006-2470RB), wiring details in the wiring diagram. Note: The mounting location will potentially be different for the tank on each baler model. Due to various baler designs and modifications, Harvest Tec does not offer a specific mounting location for each baler model. Once a mounting location has been identified, mount the tank vertically as shown (right) with the tank lid on the top using the included hardware. Next locate the dye marking spray assemblies shown (below).
Mount one tip assembly on the right side of the baler positioning the tip to allow the tip to begin spraying the bale when the door opens. Below (left) is an example of the tip assembly mounted next to the End of Bale sensor. The nozzle holder bracket can be bent or adjusted as needed to position properly. *Round balers must use tip (004-TX-26)
Mount the second tip assembly on the left side of the baler in a similar position to allow the tip to begin spraying the bale as the door opens (right).
Routing the Hose Using the supplied 1/4" hose (002-9006) connect to the pump and secure with the hose clamps (003-9002). Route the hose to each tip assembly by using the 1/4" Barbed Tee (003-T1414) to go to each side of the baler. Be sure to avoid moving parts.
13

Wiring Diagram
1. Connect the power harness (006-2470P) to the tractor convenience outlet keyed power switch using the red wire with fuse to the positive side and the black wire to the negative. a. Any modifications of the power harness will void the warranty. Contact Harvest Tec before modifications are made.
2. The power harness (006-2470P) will mount on the tractor connected to the control box (006-2473RB) with the 12 pin male deutsch connection and the opposite end down to the draw bar.
3. Connect the Baler Pwr/Comm Harness (006-2470RB) to the power harness (006-2470P). 4. Route the Pwr/Comm Harness (006-2470RB) on the baler to each moisture sensor on both sides of bale
chamber (006-4641H). If the baler is a CNH Rollbelt or Kubota round baler, sensors are pn 006-4641HX. 5. Connect the USB charging/comm cord for the phone or tablet being used, to that device and the 201
control box (006-2473RB). 6. When using a Fixed Chamber baler or Dye Marker the End of Bale Sensor kit will need to be added to the
system in order to see when the baler door opens to eject a bale. Part number (200FCA). Connect the sensor to the End of Bale (EOB) connection on the Baler Pwr/Comm Harness (006-2470RB). 7. When using the optional Dye Marker (200DM) connect 4 pin round end of the H2O harness (006-2470C) to the Dye Marker (DM) connection on the (006-2470RB) harness. Then connect the two straight spade connections with only the white wire to the push switch (006-2850). The remaining two connections with 90 degree female spades will connect to the pump.
System wiring diagram

201 Control Box 006-2473RB
H2O Wired Power Harness 006-2470P

Phone or Tablet (not included)
Phone or Tablet USB charging/comm cable
(not included)
Power Terminals (Connect to keyed
power source)

Baler Pwr/Comm Harness 006-2470RB (18')

End of Bale Sensor 006-7400
(Complete Kit 200FCA)
*Required on Fixed Chamber Balers & When Using Dye Marker

H2O Harness (10') 006-2470C

Dye Marker (200DM)

Moisture Disc 006-4641H or 006-4641HX
(CNH Rollbelt & Kubota Round Baler)

*If needed an optional 8' Pwr/Comm harness extension is available (not included), part number 006-2470BL2. 14

Downloading H2O App
The H2O App is available on any Apple or Android device running with the current operating system software and one previous version. Download the app by searching for H2O Sensor. App icon shown right.

Screen Definitions Main Screen
Brightness Adjustment ­ Tap to switch between day and night time brightness
Current Moisture Reading ­ Information will display once hay enters the bale chamber

Connection Signal - When connection is made with the control box light will turn Green
Red ­ Not Connected Green - Connected

Current App Version (example)
Settings Screen
Dye Marker System
Fixed Chamber Baler Activate when operating a fixed chamber baler Home Tab ­ Select to change to Home Screen

Settings Tab ­ Select to switch to Settings Screen
On / Off Slide ­ Slide to the right to turn On Setting. The bar will turn red or green (dependent on device)
Serial number of system 15

Operation

After installation of the H2O app, turn the system on by turning the key in the tractor on. When the connection is made the green light on the control box will illuminate.

Reading Moisture

Low Moisture Reading Range

High Moisture Reading Range

With the hay entering bale chamber, current moisture will be displayed once the bale starts to form

If the moisture being read is Less than 5%, then the reading will
appear as shown above

If the moisture being read is Greater than 60%, the reading will
appear as shown above

Fixed Chamber Balers Only- *200FCA End of Bale Sensor Kit Required

When using a fixed chamber baler, turn on the setting as shown, and enter the time to make a bale (seconds). This time
is used only until a 3 bale rolling average time is calculated.

Previous bale moisture will now display. *Current moisture will update when 1/2 of the next bale is
made and / or if using dye sprayer.

The first half of the first bale "--" will be displayed. As the system operates, the system will use the time between End of Bale signals to calculate an actual time per bale and then use a 3 bale rolling average for the time the current moisture reading is displayed. *If you would like to see the previous bale moisture when not using a Fixed Chamber baler the optional
End of Bale Sensor kit will need to be installed (200FCA) and dye marker setting turned `On'.

16

Operation (continued)
Dye Marker System

When using the dye marker turn on the setting as shown and select the desired moisture to mark a bale.
*Bales at or above this moisture level will be marked.

Dye Marker icon will now appear on the home screen. The last bale moisture will be highlighted in red and the
bale will be marked at or above the set moisture.

Dye Marker Notes · When the Dye Marker is activated by the moisture setting it will spray 3 seconds once per End of Bale (EOB)
cycle. After an EOB signal the dye marker is then reset to be able to spray again for 3 seconds once on the next bale. · A full tank of dye is estimated to mark 50-60 bales.

Dye Sprayer Override

If you would like to mark a bale for any reason, press the bale icon which will cause it to turn green. *At the next End of Bale signal the dye marker will mark the bale and the manual override will no longer be green.
When the manual override is used the last bale moisture will not highlight in red.
17

H2O Firmware Update through App
When there is an update available for the H2O system the following information will appear and the steps listed will need to be followed.
Once an operator downloads the app update (internet connection required) the "update available" symbol will appear along with the version number of the available update once connected to the system.
At this point the system can run without updating if the operator chooses. The icon will simply remain on the screen.
Once the operator decides to perform the software update, they will press the version number or upload arrow to begin.
Internet connection is not required to perform the update to the module once the app is downloaded

Once the update is initiated, the system will enter update mode
The status light will turn red
A green loading symbol will begin to circulate on the screen

A status bar with then appear to show the update progress
This can take 3-5 minutes to load software

Once the status bar load completely, the system will boot back up
The status light will again turn green
The updated version number will be shown at the bottom of the screen

18

Pin Outs

H2O Tractor Module 006-2473RB

Pin 1 Red

Module Power

Pin 2 Red/Black

EOB +

Pin 3 Black

EOB -

Pin 4 Grey

Left Moisture Sensor

Pin 5 Brown

Right Moisture Sensor

Pin 6 Purple

EOB Signal

Pin 7 Yellow

CAN +

Pin 8 Green

CAN -

Pin 9 Red/White

Dye Marker 12V +

Pin 10 Black/White Dye Marker 12V -

Pin 11 Blue

Dye Marker Prime

Pin 12 Black

Ground

H2O Tractor Harness 006-2470P at Module Plug

Pin 1 Red

Module Power

Pin 2 Red/Black

EOB +

Pin 3 Black

EOB -

Pin 4 Grey

Left Moisture Sensor

Pin 5 Brown

Right Moisture Sensor

Pin 6 Purple

EOB Signal

Pin 7 Yellow

Not Used

Pin 8 Green

Not Used

Pin 9 Red/White

Dye Marker 12V +

Pin 10 Black/White Dye Marker 12V -

Pin 11 Blue

Dye Marker Prime

Pin 12 Black

Ground

Baler Communication Harness 006-2470RB at hitch

Pin 1 Red/Black

EOB +

Pin 2 Black

EOB -

Pin 3 Grey

Left Moisture Sensor

Pin 4 Brown

Right Moisture Sensor

Pin 5 Purple

EOB Signal

Pin 6 Red/White

Dye Marker 12V +

Pin 7 Black/White Dye Marker 12V -

Pin 8 Blue

Dye Marker Prime

End of Bale Sensor (EOB) 006-2471B

Pin 1 Brown

EOB +

Pin 2 Blue

EOB -

Pin 3 N/A

Not Used

Pin 4 Black

EOB Signal

Dye Marker H2O Harness 006-2470C

Pin 1 Red

DS +

Pin 2 Black

DS -

Pin 3 White

DS Prime

Pin 4 N/A

Not Used

19

1 2 8 7

3 4 6 5

1 3 2
4
1 3 2
4

Parts Breakdowns Installation Option A

1

2

3

7

4

5

6

Ref Description

Part #

Qty

1 Baler Pwr/Comm Harness 006-2470RB 1

2 201 Series Control Box 006-2473RB 1

3 Tractor Power Harness 006-2470P

1

4 Plastic Pad

006-4641FX 2

Ref Description

Part #

Qty

5 Plastic Isolator

006-4641I

2

6 Plastic Bushing

006-4641G

2

7 Moisture Disc

006-4641HX 2

NP 8' Pwr/Comm Ext. 006-2470BL

(optional)

Moisture Assembly (Ref 4-7) 030-4643C

20

Installation Options B  G

1

2

3

7

4

5

6

Ref Description 1 Baler Pwr/Comm Harness 2 201 Series Control Box 3 Tractor Power Harness 4 Plastic Pad

Part #

Qty

006-2470RB 1

006-2473RB 1

006-2470P 1

006-4641F 2

Ref Description 5 Plastic Isolator 6 Plastic Bushing 7 Moisture Disc NP 8' Pwr/Comm Ext. (optional)

Part #

Qty

006-4641I

2

006-4641G 2

006-4641H 2

006-2470BL

Moisture Assembly (Ref 4-7)

030-4643

Fixed Chamber End of Bale Sensor Kit

1

3

2

Ref Description

Part #

Qty

1 End of Bale Sensor 006-7400

1

2 End of Bale Bracket 001-4648RB 1

Ref Description Part #

Qty

3 EOB Extension 006-7400EXT 1

Complete Kit

200FCA

21

Precision Moisture Dye Marker
1 2

9 8
7
6 5 4 3

11 10

12 13 14

Assembly Example

Ref Description

Part #

Qty

1 H2O Harness (10') 006-2470C

1

2 Tank & Pump

005-9015

1

3 Nozzle Cap

004-4723

4

4 Tip - Yellow

004-TX-26

2

5 Tip Strainer (Green) 004-1203-100 2

6 Nozzle Body

004-4722

2

7 Nozzle Holder

001-4215

2

Ref Description

Part #

Qty

8 1/4" Street Elbow

003-SE14F

2

9 Check Valve

007-1207VB 2

10 1/4" Straight Fitting 003-A1414VB 2

11 Push Switch

006-2850

1

12 1/4" All Barb Tee

003-T1414

1

13 Mini Hose Clamp

003-9002

6

14 1/4" Hose

002-9006

40

NP Red Dye

009-0800

1

NP End of Bale Sensor Kit 200FCA

1

Complete Assembly

030-200DM

22

Harvest Tec LLC. Warranty and Liability Agreement
Harvest Tec, LLC. will repair or replace components that are found to be defective within 12 months from the date of manufacture. Under no circumstances does this warranty cover any components which in the opinion of Harvest Tec, LLC. have been subjected to negligent use, misuse, alteration, accident, or if repairs have been made with parts other than those manufactured and obtainable from Harvest Tec, LLC. Our obligation under this warranty is limited to repairing or replacing free of charge to the original purchaser any part that in our judgment shows evidence of defective or improper workmanship, provided the part is returned to Harvest Tec, LLC. within 30 days of the failure. If it is determined that a non-Harvest Tec branded hay preservative has been used inside the Harvest Tec applicator system where the failure occurred, then Harvest Tec reserves the right to deny the warranty request at their discretion. Parts must be returned through the selling dealer and distributor, transportation charges prepaid. This warranty shall not be interpreted to render Harvest Tec, LLC. liable for injury or damages of any kind, direct, consequential, or contingent, to persons or property. Furthermore, this warranty does not extend to loss of crop, losses caused by delays or any expense prospective profits or for any other reason. Harvest Tec, LLC. shall not be liable for any recovery greater in amount than the cost or repair of defects in workmanship. There are no warranties, either expressed or implied, of merchantability or fitness for particular purpose intended or fitness for any other reason. This warranty cannot guarantee that existing conditions beyond the control of Harvest Tec, LLC. will not affect our ability to obtain materials or manufacture necessary replacement parts. Harvest Tec, LLC. reserves the right to make design changes, improve design, or change specifications, at any time without any contingent obligation to purchasers of machines and parts previously sold. Revised 6/22
23

HARVEST TEC, LLC. P.O. BOX 63
2821 HARVEY STREET HUDSON, WI 54016 USA
PHONE: 715-386-9100 FAX: 715-381-1792
Email: info@harvesttec.com