RF EXPOSURE EXEMPT REPORT

REPORT No.: SZ24100261S01

Applicant and Report Details

APPLICANT: Realme Chongqing Mobile Telecommunications Corp., Ltd.

PRODUCT NAME: Earphone

MODEL NAME: RMA2415-A

BRAND NAME: realme

FCC ID: 2AUYFRMA2415-A

STANDARD(S): 47 CFR Part 2(2.1093)

RECEIPT DATE: 2024-11-05

TEST DATE: 2024-11-08 to 2024-12-07

ISSUE DATE: 2024-12-13

Edited by: Zeng Xiaoying (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

Directory

  • 1. Technical Information
  • 1.1 Applicant and Manufacturer Information
  • 1.2 Equipment Under Test (EUT) Description
  • 1.3 Applied Reference Documents
  • 2. Device Category and RF Exposure Limit
  • 3. Maximum Average Power Summary
  • 4. RF Exposure Assessment
  • Annex A Testing Laboratory Information

Change History

VersionDateReason for change
1.02024-12-13First edition

1. Technical Information

Note: Provide by applicant.

1.1 Applicant and Manufacturer Information

Applicant:Realme Chongqing Mobile Telecommunications Corp., Ltd.
Applicant Address:No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China
Manufacturer:Realme Chongqing Mobile Telecommunications Corp., Ltd.
Manufacturer Address:No.178 Yulong Avenue, Yufengshan, Yubei District, Chongqing, China

1.2 Equipment Under Test (EUT) Description

Product Name:Earphone
Sample No.:3#, 6#, 7#
Hardware Version:Earphone: Steel_E1_R&L_V2_1
Charging case: Steel_CHG_B1_V2_1
Software Version:Earphone: V1.1.0.9
Charging case: V007
Equipment Type:Bluetooth
Operating Frequency Range:2402MHz-2480MHz
Modulation Type:FHSS (GFSK(1Mbps), π/4-DQPSK(EDR 2Mbps), 8-DPSK(EDR 3Mbps))
Antenna Type:FPC Antenna
Antenna Gain:Left: 0.2dBi; Right: 0.05dBi

1.3 Applied Reference Documents

Leading reference documents for testing:

IdentityDocument TitleMethod Determination /Remark
47 CFR Part 2(2.1093)Radio Frequency Radiation Exposure Assessment: Portable devicesNo deviation
KDB 447498 D01v06General RF Exposure GuidanceNo deviation

Note 1: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table.

Note 2: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals.

2. Device Category and RF Exposure Limit

Per user manual, based on 47 CFR 2.1093, this device belongs to portable device category with General Population/Uncontrolled exposure.

Portable Devices:

47 CFR 2.1093(b)

For purposes of this section, a portable device is defined as a transmitting device designed to be used so that the radiating structure(s) of the device is/are within 20 centimeters of the body of the user.

General Population/Uncontrolled Exposure:

47 CFR 2.1093(d) (2)

Limits for General Population/Uncontrolled exposure: 0.08 W/kg as averaged over the whole-body and spatial peak SAR not exceeding 1.6 W/kg as averaged over any 1 gram of tissue (defined as a tissue volume in the shape of a cube). Exceptions are the hands, wrists, feet and ankles where the spatial peak SAR shall not exceed 4 W/kg, as averaged over any 10 grams of tissue (defined as a tissue volume in the shape of a cube). General Population/Uncontrolled limits apply when the general public may be exposed, or when persons that are exposed as a consequence of their employment may not be fully aware of the potential for exposure or do not exercise control over their exposure. Warning labels placed on consumer devices such as cellular telephones will not be sufficient reason to allow these devices to be evaluated subject to limits for occupational/controlled exposure in paragraph (d)(1) of this section.

3. Maximum Average Power Summary

Wireless ModeChannelFrequency (MHz)Max. Average Power (dBm)Tune-up Limit (dBm)
BluetoothCH 3924416.407.00

Note 1: According to KDB 447498, SAR test exclusion conditions are based on source-based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up tolerance, and the minimum test separation distance required for the exposure conditions.

Note 2: The output power refers to report (Report No.: SZ24100261W01/W02).

4. RF Exposure Assessment

Standalone Transmission SAR Evaluation:

1. According to KDB 447498 section 4.3.1, the 1-g SAR test exclusion thresholds at test separation Distances≤ 50 mm are determined by:

[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)]·[√f(GHz)] ≤ 3.0.

  • f(GHz) is the RF channel transmit frequency in GHz
  • Power and distance are rounded to the nearest mW and mm before calculation
  • The result is rounded to one decimal place for comparison

2. When the device is used, 5mm as the most conservative minimum test separation distance was used for evaluating.

ChannelFrequency (MHz)Max. Tune-up Power (dBm)Max. Power (mW)Test Distance (mm)ResultExclusion Thresholds for 1-g SAR
CH 3924417.005.0151.573.0

Note: The conduction power was rounded in mW.

3. When standalone SAR is not required to be measured, per KDB 447498 D01v06 4.3.2), the following equation must be used to estimate the standalone 1g SAR.

Estimated SAR = [√f(GHz) / 7.5] · [Max. power of channel, mW / Min. Separation Distance, mm]

ModeMax. Tune-up Power (dBm)Exposure PositionTest Distance (mm)Estimated SAR (W/kg)
Bluetooth7.00Body50.209

Simultaneous SAR Evaluation:

This device only incorporates one Bluetooth transmitter, therefore simultaneous SAR evaluation is not required.

Annex A Testing Laboratory Information

1. Identification of the Responsible Testing Laboratory

Laboratory Name:Shenzhen Morlab Communications Technology Co., Ltd.
Laboratory Address:FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China
Telephone:+86 755 36698555
Facsimile:+86 755 36698525

2. Identification of the Responsible Testing Location

Name:Shenzhen Morlab Communications Technology Co., Ltd.
Address:FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

3. Facilities and Accreditations

All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174.

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7935735 Morlab Acrobat Distiller 9.3.2 (Windows)

Related Documents

Preview Realme RMA2415-A Earphone EMC Test Report - Conducted and Radiated Emissions
Official test report for the Realme RMA2415-A Earphone, detailing conducted and radiated emission compliance testing according to 47 CFR Part 15 Subpart B by Shenzhen Morlab Communications Technology Co., Ltd.
Preview Realme RMX3472 RF Test Report: Comprehensive RF Performance Analysis
Official RF test report for the Realme RMX3472 mobile phone, detailing compliance with 47 CFR Part 2 and other relevant standards. Includes test results for power, bandwidth, stability, and emissions.
Preview Realme RMA2415-A Wireless Earbuds: External Views and FCC ID
Comprehensive external photographs and descriptions of the Realme RMA2415-A wireless earbuds and their charging case, detailing all angles and key features, along with FCC identification information.
Preview Realme RMA2407 Charging Case - Technical Specifications
Discover the technical specifications of the Realme RMA2407 Charging Case, including its input/output power, battery capacity, dimensions, and manufacturer details from Realme Chongqing Mobile Telecommunications Corp., Ltd.
Preview Realme RMX1971 Mobile Phone FCC EMC Test Report
This document details the FCC Electromagnetic Compatibility (EMC) test results for the Realme RMX1971 mobile phone, covering radiated and conducted emissions testing performed by Shenzhen BALUN Technology Co., Ltd.
Preview Realme RMX3516 Safety Guide and FCC Compliance Information
Official safety guide and FCC regulatory conformance details for the Realme RMX3516, covering FCC statement, compliance, and RF exposure (SAR) limits.