Installation Guide for Altronix models including: T3KAK33F16 16 Door Kit with Fused Outputs, T3KAK33F16, 16 Door Kit with Fused Outputs, Fused Outputs, 16 Door Kit, Door Kit
Altronix T3KAK33F16 | 16-Door Access and Power Integration K
File Info : application/pdf, 4 Pages, 777.32KB
DocumentDocumentAccess & Power Integration T3KAK33F16 16 Door Kit with Fused Outputs Fully assembled kit includes: - Trove3 enclosure with TKA3 Altronix/Keyscan backplane - (2) eFlow6NB - Power Supply/Chargers - (2) ACM8 - Fused Access Power Controllers - (1) PD4UL - Fused Power Distribution Board - (1) T16175 Transformer (packed separately) Installation Guide All components of this Trove kit are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information. All registered trademarks are property of their respective owners. More than just power.TM Rev. T3KAK33F16_112119 Installing Company: _________________________ Service Rep. Name: __________________________________________ Address: _________________________________________________________ Phone #: _________________________ Overview: Altronix T3KAK33F16 Trove Keyscan kit is pre-assembled and consist of Trove3KA3 enclosure/backplane with factory installed Altronix power supply/chargers, transformer, and sub-assemblies. This kit also accommodates various combinations of Keyscan boards for up to sixteen (16) doors in a single enclosure. Power Power 120VAC Supply Supply 60Hz Boards Boards Input Input Battery Altronix Current Fuse Fuse Model Number (A) Rating Rating T3KAK33F16 7.0 5A/ 10A/ 250V 32V Configuration Chart: Nominal DC Output Voltage [DC] [Aux] 24VDC Output Range (V) 24VDC Output Range (V) Maximum Supply Current for Main and Aux. Outputs on each Power Supply board and each ACM8 Access Power Controller's outputs 20.19- 20.1926.4 26.4 24VDC @ 5.8A Current Fail-Safe/ Per Fail-Secure ACM8 or Dry Form Output "C" Outputs (A) 16 2.5 ACM8 Board Input Fuse Rating 10A/ 250V ACM8 Board Output Fuse Rating 3.5A/ 250V PD4UL Board Output Fuse Rating 3.5A/ 250V Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. Fig. 1 2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the Enclosure enclosure's upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Edge of Enclosure Place the enclosure's upper keyholes over the three upper screws. Install the three lower screws Tamper Switch and make sure to tighten all screws. (included) 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2" To Access Control Panel or UL Listed Reporting Device from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. 4. Mounting Included T16175 Transformer: To prevent damage, T16175 is packed separately and needs to be installed by the user. Fig. 2 It is to be mounted on the left of the backplane, next to PD4UL power distribution board. Please follow the steps below: a. Orient T16175 so the terminals are facing down (Fig. 4, 4a, pg. 3). T16175 b. Put T16175's upper mounting holes over two mounting pems on backplane and secure with two (2) lock nuts (Fig. 4, 4a, pg. 3). Terminals Lock Nut c. Use included mounting bracket to secure T16175's lower mounting holes. Align pems on the bracket with T16175's lower mounting holes and corresponding holes in the backplane. Mounting Bracket TKA3 Push the bracket's pems through the holes and secure from the back side of the backplane with two (2) lock nuts (Fig. 2, pg. 2). Mounting Hole d. Connect AC power 115VAC, 50/60Hz to primary leads (black and white) from terminal numbers 1 and 2 (Fig. 3, pg. 2). e. Measure output voltage across the secondary leads (yellow and blue) from terminal numbers 7 and 12 (Fig. 3, pg. 2) before connecting devices. This helps avoiding potential damage. f. Connect PD4UL (factory mounted) to the secondary leads (yellow and blue) from terminal numbers 7 and 12 (Fig. 3, pg. 2). 5. Mount Keyscan boards to backplane, refer to page 3. 6. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB, ACM8/CB Installation Guide for ACM8, and T16175 Installation Guide for T16175 for further installation instructions. Fig. 3 - T16175 Wiring Configuration 654321 12 11 10 9 8 7 115VAC (Primary) Input - 2 - 16VAC (Secondary) Output T3KAK33F16 Installation Guide T3KAK33F16: Configuration of Keyscan Boards 1. Mount appropriate Keyscan boards into the correct positions (Fig. 4, pg. 3) by postioning spacers over appropriate holes in the backplane and depressing down on board to secure spacer to the backplane (Fig. 4b, pg. 3). 2. Fasten backplane to Trove2 enclosure utilizing pan head screws (provided). Fig. 4 Fig. 4a Lock Nuts ON OFF - 24V ON - 12V Altronix - eFlow6NB L G N AC1 AC DC NC C NO NC C NO AC FAIL BAT FAIL TRIGGER EOL NO GND SUPERVISED RESET +AUX- ON OFF - 24V ON - 12V Altronix - eFlow6NB L G N AC1 AC DC NC C NO NC C NO AC FAIL BAT FAIL TRIGGER EOL NO GND SUPERVISED RESET +AUX- - BAT + - DC + - BAT + - DC + Keyscan CA250B, CA4500B CA8500B Keyscan OCB8 Keyscan OCB8 F1 F2 1P 1N 2P 2N 3P 3N 4P 4N F3 Altronix T16175 Terminals Bracket Altronix T16175 (packed separately) P N Altronix - PD4UL F4 INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP Altronix - ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON 1234 1234 FACP Altronix - ACM8 MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control Keyscan DPS15 Locknut Keyscan CA250B, CA4500B CA8500B Keyscan DPS15 Locknut Keyscan CIM Keyscan OCB8 Keyscan OCB8 Keyscan CIM T3KAK33F16 Installation Guide Plastic Spacer pre-mounted into Keyscan modules Insert into TKA2 or TKA3 backplane Fig. 4b - 3 - 2.00" (50.8mm) Enclosure Dimensions (H x W x D approximate): 36.12" x 30.125" x 7.06" (917.5mm x 768.1mm x 179.3mm) 2.00" (50.8mm) 1.25" (31.8mm) 7.12" (222.3mm) 9.5" (241.3mm) 9.5" (241.3mm) 1.78" (45.2mm) 1.55" (39.4mm) 1.25" (31.8mm) 1.07" (27.2mm) 30.12" (768.1mm) 14.01" (355.9mm) 14.01" (355.9mm) 2" (50.8mm) 1.10" (27.9mm) G G 10.75" (273.1mm) 10.75" (273.1mm) 10.62" (269.8mm) 36.12" (917.5mm) 33.63" (854.2mm) 10.62" (269.8mm) 10.75" (273.1mm) 10.75" (273.1mm) 1.25" (31.8mm) 2" 8.75" (222.3mm) (50.8mm) 8.62" (219mm) 8.75" (222.3mm) 7.06" (179.3mm) 1.25" (31.8mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IIT3KAK33F16 I28U MEMBER - 4 - T3KAK33F16 Installation Guide