User Manual for LEDLightingHut models including: LET-4061DMX, LET-4061DMX LED Fiber Optic Light Engine, LED Fiber Optic Light Engine, Fiber Optic Light Engine, Optic Light Engine, Light Engine, Engine
24W RGBW DMX Star Ceiling Fiber Optic LED Illuminator
ISO9001:2000 CERTIFIED MODEL:LET-4061DMX LIGHT ENGINE USER MANUAL Accessories: Fiber Connector .....1 PC Wireless Remote Controller.....1 PC (Optional)
LIGHT ENGINE USER MANUAL MODEL:LET-4061DMX Accessories: Fiber Connector ..............................1 PC Wireless Remote Controller...............1 PC (Optional) Power Adapter.................................1 PC User Manual ....................................1 PC Signal Cable ....................................1 PC ISO9001:2000 CERTIFIED LIGHT ENGINE USER MANUAL Welcome to use LET series of professional light engine. Please read the manual carefully before turning on the light engine.If you have any questions concerning the operation or maintenance, please contact your wholesaler. Safety Instruction 1. Make sure the Light Engine and Power Source have the same voltage; 2. Keep out of rain or moist area to avoid shock hazards; 3. Avoid to work in high ambient temperature ( >40); CHAPTER 1 LET-4061DMX 1. Technical Data Voltage: 12V DC Power: 30W LED Color: LED Module: RGBW 1-4*6W Life of LED : 50000H Size: 182×115×90mm3 Gross Weight: 0.8Kg Standard Aperture:14mm/18mm/22mm 2. Installation dimension of light engine (see Fig.1): DIP DIM DC12V 172 182 90 90 AERIAL POWER SWITCH DIP DIM DC12V 182 115 99 115 Fig.1 3. Light Engine Setup: Light engine control: a. When a single light source is running by itself or controlled by a remote control, it should be set as the master machine. b. When multiple light engines of the same model are connected into a group, the light engines can be set as either slave or master machine as follows: (1) When a DMX512 console is connected to the group, all light engines should be set up as the slave machines and will follow the program run in the console. 1 (2) When there is no DMX512 console connected, the group must run the master & slave mode: one and only one light engine is set as the master machine, and the rest are set as the slave machines. In the group, all the slave machines run the program following the master machine. c. The master and slave machine setup through the DIP switch (1=ON, 0=OFF) Master light engine:the 10th DIP Switch SW10 is ON When the SW10 is ON (master machine status), SW1-SW5 represent the built-in program, SW6-SW8 are invalid, and SW9 is used to turn on and off the remote control function.(Picture 2) ON OFF 1 2 4 8 16 32 64 128 R S/M DIP 1 2 3 4 5 6 7 8 9 10 7 8 9 10 Remote Master Fig.2 Slave Light engine: the 10th DIP switch SW10 is OFF (1) When SW10 is OFF (slave machine state), SW1-9 are used to indicate the DMX address, and the remote control function is invalid. (2) When all the slave machines have the same DMX address of 001 (shown in Figure 5), they will work synchronously with the master machine. (3) The Slave machines could also have an increasing DMX address by 4, for example, 001, 005, 009...when there is a DMX console connected, or 005, 009, 013...when the group runs the master-slave mode. As such, all light engines will run the program with a scrolling effect. DIP switch settings (Figure 6) ON OFF 1 2 4 8 16 32 64 128 256 S/M DIP 1 2 3 4 5 6 7 8 9 10 Fig.5 DMX add. 001 002 003 004 005 --009 --013 DIP Switch 1 2 3 4 5 6 7 8 9 10 1000000000 0100000000 1100000000 0010000000 1010000000 ---------1001000000 ---------1011000000 Fig.6 d. DMX address calculation: For example: DMX address 009=8(4)+1(1), 013=8(4)+4(3)+1(1) e. The dimming knob: The knob (see installation diagram) has been adjusted to the maximum by default.Turning the knob left and right could adjust the brightness of the light engine. f. Number of DMX channels and corresponding function: CH1: Red CH2: Green CH3: Blue CH4: White CH5:Twinkle Speed 2 g. The connection diagram of the light engines when there is a DMX console connected: DMX512 console AERIAL POWER SWITCH DMX IN DMX OUT DIP DIM DC12V AERIAL POWER SWITCH DMX IN DMX OUT DIP DIM DC12V AERIAL POWER SWITCH DMX IN DMX OUT DIP DIM DC12V Slave1 Slave2 Slave3 h. The connection diagram of the light engines when the group runs the master-slave control mode: AERIAL POWER SWITCH DMX IN DMX OUT DIP DIM DC12V AERIAL POWER SWITCH DMX IN DMX OUT DIP DIM DC12V AERIAL POWER SWITCH DMX IN DMX OUT DIP DIM DC12V AERIAL POWER SWITCH DMX IN DMX OUT DIP DIM DC12V Master Slave1 Slave2 Slave3 i. Connection diagram of DMX signal cable: The signal cable adopts RJ45 shielded wire (i.e. network cable). 1 SIGNAL+ 2 SIGNAL3 4 5 6 7 GND 8 GND 4. The remote control: a. Before using the remote control: (1) Make sure that the remote control has the battery, which has enough power. (2) Make sure that the DIP SW9 and SW10 on 7 8 9 10 ON the light engine are at the ON position. (3) The remote control needs to be paired with Remote Master the light engine before use. (It has been paired with DMX ADDRESS by default ). (4) After the pairing is completed, the remote control is ready for use. (5) The light engine only accepts the control of the paired remote control. b. How to pair the remote control and the machine: (1) Press and hold any one of the four pairing keys on the remote control.(Picture 7) BREATH - FLASH - TWINKLE - DMX ADDRESS Fig.7 (2) Turn on the power of the light engine, and the machine starts to work. (3) The green indicator next to the DIP switches will flash 2 times slowly and 3 times quickly. (4) The remote control and the machine are successfully paired. (5) Release the pairing key. 3 c. The pairing rule of the remote control and the light engine: (1) The four keys in the last row of the remote control, BREATH - FLASH - TWINKLE - DMX ADDRESS are the four Pairing Keys. (2) Each Pairing Key can be paired with multiple light engines and will have the same effect. (3) Each light engine can be paired with at most four different Pairing Keys, namely BREATH FLASH TWINKLE DMX - - - ADDRESS respectively. These four Pairing Keys with different icons can come from different remote controls. (4) Once the device is successfully paired with the remote control, the pairing function cannot be canceled, but can be overwritten. (5) For the same light engine, the pairing key with the same icon can overwrite the previous pairing key. (6) The light engine can be paired no matter it is a master or a slave machine. Dimming+/(6-tier) OFF ON RED GREEN BLUE WHITE The Pairing key CYAN YELLOW PURPLE RGBW JUMP2 JUMP4 JUMP6 COLOR SP+ FADE2 FADE4 FADE6 COSPL-OR BREATH + FLASH + TWINKLE + FUN. OFF BREATH - FLASH - TWINKLE - DMX ADDRESS RF controller ON/OFF Static colors (Red, Green, Blue, Cyan, Yellow, Purple, RGB+W) JUMP2White and Blue Jump JUMP4White, Blue, Green and Red Jump JUMP6White, Blue, Green, Red, Yellow, Cyan Jump FADE2White and Blue Fade FADE4White, Blue, Green and Red Fade FADE6White, Blue, Green, Red, Yellow, Cyan Fade COLOR SP +/- Color Cycling Speed Adjustment (7-tier) BREATH +/-Breathing Effect (7-tier ) FLASH +/- Strobe Effect (7-tier speed) TWINKLE +/- Twinkle Effect (7-tier ) FUN.OFFTermination of Breathing/Strobe/Twinkle Effect DMX ADDRESS: (Paring Key only, DMX function invalid ) Note: 1. Press "BREATH" or "FLASH" key when the light engine works, the machine will run the effect of fading or strobe at the particular color when pressing. If "FUN.OFF" is pressed, the current breathing or strobe effect will be cancelled and the program before will be restored. 2. After turned on, the light engine will automatically run the program before it is powered off. 3. Both the dimming knob on the light engine and the dimming button on the remote control can adjust the brightness. They are effective at the same time, and the dimming effects will be superimposed. For example, to set the light engine the brightest, both the dimming knob and the dimming button need to be adjusted/pressed to the maximum. 4 Attached Table: PRG NO. 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 DIP SWITCH(1=ON, 0=OFF) 1 2 3 4 5 6 7 8 9 10 0000000000 1000000001 0100000001 1100000001 0010000001 1010000001 0110000001 1110000001 0001000001 1001000001 0101000001 1101000001 0011000001 1011000001 0111000001 1111000001 0000100001 1000100001 0100100001 FUNCTION No Light White Blue Green Red Yellow Cyan W, B, G, R, Y, C Skip (2s) W, B, G, R, Y, C Skip (4s) W, B, G, R, Y, C Skip (8s) W, B, G, R, Y, C Fade (2s) W, B, G, R, Y, C Fade (4s) W, B, G, R, Y, C Fade (8s) White, Blue Skip (2s) White, Blue Skip (2s) White, Blue Skip (2s) White, Blue Fade (2s) White, Blue Fade (4s) White, Blue Fade (8s) 5 Chapter 2 Installation of Fiber Optic 1. Connecting the fiber optic with Light Engine: Solid core fiber optic cable(See Fig. 1): (1) Cut the fiber to the specified length. The cross section should be vertical to the fiber and keep clean and smooth. (2) Peel off 50-100mm of the PVC jacket of the fiber optic cable (not necessary if there is no PVC jacket). Be careful not to hurt the fiber optic cable. (3) Unscrew the PG Connector and insert the fiber optic cable into the PG Connector and Fiber Connector until the end of the cable is flush with the Fiber Connector. Screw tightly the PG Connector. (4) Insert the finished Fiber Connector into the Fixing Flange, screw tightly the screw. PG Connector Fiber Optic Front Case Fiber Connector Fixing Flange Fig. 1 2.Installation of the end part of the Multi-String fiber optic: (1) Drill holes on the installing board according to the design. Then insert the fiber optic string into holes and fix it with epoxy glue. Trim the end of the fiber string to be flush with the board or at a required length. Fasten the other end of the fiber string to a harness and insert the harness into PG Connector and Fiber Connector. Apply the hot knife to cut fiber end flush with the Fiber Connector. (See Fig.2). (2) Insert the finished Fiber Connector into the Fixing Flange and screw tightly the screw. Fig. 2 6Corel PDF Engine Version 16.1.0.843 CorelDRAW X6