KALLISTA INSTALLATION INSTRUCTIONS

Pressure Balance Trim

Models: P24015, P24016, P24115, P24116, P24215, P24216, P24415, P24416

IMPORTANT INSTRUCTIONS

READ AND SAVE FOR THE CONSUMER

WARNING: Risk of scalding or other severe injury.

NOTICE: Only apply silicone based lubricants to these valves. Do not use petroleum based lubricants. Petroleum based lubricants will harm the O-rings, seals, and plastic components.

The installer is responsible for installing the valve and adjusting the maximum water temperature of this pressure-balanced valve according to instructions. This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.

If you do not understand any of the installation or temperature adjustment instructions in this document, in the United States please contact KALLISTA Customer Service at 1-888-4KALLISTA. Outside the U.S., please contact your distributor.

IMPORTANT NOTICE TO INSTALLERS!

Please fill in the blanks in the adjacent box and on the valve label. Then insert these instructions into the plastic bag included with the valve package, and attach the plastic bag to the valve handle for the homeowner's reference.

NOTICE TO HOMEOWNERS!

This device has been preset by _______________________ of _______________________________ to ensure a safe maximum temperature. Any change in the setting may raise the discharge temperature above the limit considered safe, and lead to scalds.

Date: ______________

BEFORE YOU BEGIN

KALLISTA reserves the right to make revisions in the design of products without notice, as specified in the Price Book.

1. WATER TEMPERATURE ADJUSTMENT

CAUTION: Risk of personal injury. The water temperature should never be set above 120° F (49° C).

NOTE: Do not remove the O-ring and collar at this time. Removing the O-ring and collar will change the factory setting for the maximum water temperature.

Diagram: High Flow Valve Components

Illustrates components for the High Flow Valve:

  • Valve Stem
  • Collar
  • Setscrew
  • Tab

Diagram: Standard Valve Components

Illustrates components for the Standard Valve:

  • Valve Stem
  • Collar
  • Setscrew
  • Tab
  • Valve Label
  • O-Ring
  1. Discard the plaster guard.
  2. Turn the valve clockwise to the full open position. After several minutes, check the temperature.
  3. For minor temperature changes, adjust the setscrew and recheck the temperature.
  4. For major temperature changes, remove the O-ring and the collar. Slowly turn the valve stem to adjust the maximum water temperature.
  5. Reinstall the collar with the setscrew against the tab. Reinstall the O-ring.
  6. Recheck the temperature.
  7. Turn the valve stem counterclockwise to the "OFF" position.

NOTE: After adjustment, complete the required information on the valve label (if supplied).

2. DIVERTER ASSEMBLY (IF APPLICABLE)

Diagram: Diverter Assembly Components

Illustrates components for diverter assembly:

  • Valve Stem
  • Diverter Stem
  • Diverter Actuator
  • Setscrew

Instructions mention to discard the plaster guard with dome.

NOTE: If the diverter stem has an E-clip and an O-ring, these must be removed before the actuator and guide can be installed.

  1. Position the actuator over the diverter stem.
  2. Secure with setscrew.

3. INSTALL THE FACEPLATE AND HANDLE

Diagram: Faceplate and Handle Installation Components

Illustrates components for installing the faceplate and handle:

  • Valve Stem
  • Diverter Actuator
  • Diverter Seal
  • Valve Seal
  • Faceplate
  • Screw
  • Collar
  • Setscrew
  • Handle

Instructions mention to discard the plaster guard with dome.

For tiled wall installations only, apply silicone sealant.

  1. Fit the diverter seal over the diverter actuator (if applicable) and the valve seal over the valve stem, as shown. Align the notches in the valve seal with the threaded holes in the valve.
  2. Install the faceplate onto the valve. Secure with two screws. Do not overtighten.
  3. Rotate the valve stem fully counter clockwise.
  4. Slide the collar onto the valve.
  5. Place the handle assembly over the valve stem so that the setscrew is aligned with the large groove on the valve stem. If using the lever handle, make sure that the handle points straight down. Tighten the setscrew.
  6. If supplied, remove the aerator.
  7. Run the water to flush debris, then reinstall the aerator.

NEED HELP?

Contact KALLISTA Customer Service Department:

Warranty

This product is covered under the KALLISTA® Five-Year Limited Warranty, found at kallista.com/resources/warranty. For a hardcopy of warranty terms, contact the Customer Service Department.

French Section Summary: For assistance, contact KALLISTA Customer Service at 1-888-4-KALLISTA. For spare parts, maintenance, and cleaning information, visit kallista.com. Patent information is available at kohlercompany.com/patents. The product is covered by a KALLISTA Five-Year Limited Warranty, details available at kallista.com/resources/warranty.

Spanish Section Summary: For assistance, contact KALLISTA Customer Service at 1-888-4-KALLISTA. For spare parts, care, and cleaning information, visit kallista.com. Patent information is available at kohlercompany.com/patents. The product is covered by a KALLISTA Five-Year Limited Warranty, details available at kallista.com/resources/warranty.

Models: P24015 Tuxedo Pressure Balance Trim, P24015, Tuxedo Pressure Balance Trim, Pressure Balance Trim, Balance Trim

File Info : application/pdf, 14 Pages, 895.49KB

PDF preview unavailable. Download the PDF instead.

ca174a6e5fe0f6d0a5aaaa4748e36bbdd17288d6 InstallSheet KALP24416LVBL

References

Adobe PDF Library 16.0.7 Adobe InDesign 17.3 (Windows)

Related Documents

Preview KALLISTA Faucet Lifetime Limited Warranty - Product Information
Detailed warranty information for KALLISTA faucets, covering lifetime limited warranty for residential use, 1-year for commercial use, and specific exclusions. Learn about claims, product coverage, and care instructions.